This paper reports a breathable flexible glucose biosensor with excellent flexibility and moisture/air permeability. The biosensor's electrodes are embedded in a flexible porous nanofiber polyimide substrate through electrospinning. The porous structure of this nanofiber substrate makes the biosensor breathable, effectively avoiding the body-fluid accumulation that can significantly affect measurement accuracy in long-term wearable monitoring. It also completely embeds the electrodes in the substrate preventing them from falling off, which frequently occurs in a surface-electrode structure, effectively avoiding degradation of sensing performance over time. The air-permeable film substrate was obtained by optimizing the manufacturing parameters, including spinning voltage, flow rate, solution concentration, and electrospinning distance. Three electrodes were then embedded on the flexible air-permeable substrate by inkjet printing to form the breathable glucose biosensor. The fabricated breathable flexible glucose biosensor was found to have excellent moisture (-3954.8 g/[m(2) x 24 h]) and air (-63.59 mm/s) permeability. A bending test verified the firmness of the embedded structure, and the microscopic connectivity and conductivity of the electrodes were stable. This breathable biosensor can precisely detect glucose in the linear range of 0-25 mM with a detection limit of 0.128 mM.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Practical Performance Assessment of Dry Electrodes Under Skin Moisture for Wearable Long-Term Cardiac Rhythm Monitoring Systems
    Bosnjak, Antonio
    Escalona, Omar J.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 871 - 875
  • [42] Long-term use of biosensor systems for monitoring industrial chromatographic processes
    Irtel, F
    Sosnitza, P
    Busse, M
    Faurie, R
    Fischer, L
    Ulber, R
    Scheper, T
    CHEMIE INGENIEUR TECHNIK, 2000, 72 (05) : 502 - 505
  • [43] GLUCOSE BIOSENSOR BASED ON OXYGEN-ELECTRODE .2. LONG-TERM OPERATIONAL STABILITY OF THE RECHARGEABLE GLUCOSE BIOSENSOR
    ATANASOV, P
    WILKINS, E
    ANALYTICAL LETTERS, 1993, 26 (10) : 2079 - 2094
  • [44] Development of a Low Cost Wearable Prototype for Long-Term Vital Signs Monitoring Based on Embedded Integrated Wireless Module
    Galeotti, L.
    Paoletti, M.
    Marchesi, C.
    COMPUTERS IN CARDIOLOGY 2008, VOLS 1 AND 2, 2008, : 905 - +
  • [45] Wearable Smart Textiles for Long-Term Electrocardiography Monitoring-A Review
    Nigusse, Abreha Bayrau
    Mengistie, Desalegn Alemu
    Malengier, Benny
    Tseghai, Granch Berhe
    Van Langenhove, Lieva
    SENSORS, 2021, 21 (12)
  • [46] A Long-term Wearable Vital Signs Monitoring System using BSN
    Guo, D. G.
    Tay, Francis E. H.
    Xu, L.
    Yu, L. M.
    Nyan, M. N.
    Chong, F. W.
    Yap, K. L.
    Xu, B.
    11TH EUROMICRO CONFERENCE ON DIGITAL SYSTEM DESIGN - ARCHITECTURES, METHODS AND TOOLS : DSD 2008, PROCEEDINGS, 2008, : 825 - 830
  • [47] Flexible yet Durable Microneedle Electrodes Based on Nanowire-Embedded Polyimide for Precise Wearable Electrophysiological Monitoring
    Xing, Lixiang
    Liu, Lihua
    Jin, Ran
    Zhang, Haiyue
    Shen, Yiyang
    Zhang, Siyu
    He, Ziyi
    Li, Dingwei
    Ren, Huihui
    Huang, Qi
    Cao, Xuan
    Zhang, Shaomin
    Dong, Shurong
    Cheng, Wenlong
    Zhu, Bowen
    ACS APPLIED MATERIALS & INTERFACES, 2024, 16 (42) : 57695 - 57704
  • [48] Wearable and Flexible Textile Electrodes for Biopotential Signal Monitoring: A review
    Acar, Gizem
    Ozturk, Ozberk
    Golparvar, Ata Jedari
    Elboshra, Tamador Alkhidir
    Bohringer, Karl
    Yapici, Murat Kaya
    ELECTRONICS, 2019, 8 (05)
  • [49] Breathable and sweat tolerance PPy-leather dry electrode for long-term electroencephalogram monitoring
    Zhao, Yuhan
    Zhang, Rui
    Liu, Yunqing
    Wang, Feng
    Hu, Shi
    Yang, Fenghui
    Tao, Chao
    Wu, Qiong
    Zha, Baoli
    Wu, Jiansheng
    Huo, Fengwei
    SENSORS AND ACTUATORS A-PHYSICAL, 2025, 382
  • [50] Wearable Health Monitoring System using Flexible Materials Electrodes
    Bao, Shenjie
    Gia, Tuan Nguyen
    Chen, Wei
    Westerlund, Tomi
    2020 IEEE 6TH WORLD FORUM ON INTERNET OF THINGS (WF-IOT), 2020,