Quantitative Blood Flow Imaging with Time-Resolved C-arm Cone-beam CT Imaging

被引:0
|
作者
Garrett, John W. [1 ,2 ]
Li, Yinsheng [1 ]
Montoya, Juan [1 ]
Wu, Yijing [1 ]
Li, Ke [1 ,2 ]
Strother, Charles [2 ]
Chen, Guang-Hong [1 ,2 ]
机构
[1] Univ Wisconsin Madison, Dept Med Phys, Madison, WI 53705 USA
[2] Univ Wisconsin Madison, Dept Radiol, Madison, WI 53792 USA
来源
MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING | 2020年 / 11312卷
关键词
RECONSTRUCTION;
D O I
10.1117/12.2548516
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In recent years, it has been shown that it is possible to achieve time-resolved cone-beam CT imaging using a C-arm cone-beam CT system equipped with a back-and-forth multi-sweep data acquisition mode. A reconstruction algorithm which has been referred to as SMART-RECON has demonstrated to achieve better than 1.0 frame per second (fps) temporal resolution. Recently, another innovation was introduced into SMART-RECON to achieve 7.5 fps, this innovation opens up a whole new opportunity to extract other physiological information besides the well-known cone-beam CT perfusion. In this work, we study the feasibility to obtain quantitative blood flow information from high temporal resolution time-resolved cone beam CT angiography. This new possibility would enable physicians to more accurately pinpoint occlusion sites and provide the needed image guidance to plan for endovascular therapy in acute ischemic stroke patients as an example. Numerical simulations with ground truth and preliminary clinical case studies have been conducted to demonstrate the feasibility of blood flow quantification from time-resolved CBCT angiography.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Dose and detectability for a cone-beam C-arm CT system revisited
    Ganguly, Arundhuti
    Yoon, Sungwon
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2010, 37 (05) : 2264 - 2268
  • [22] Dose and image quality for a cone-beam C-arm CT system
    Fahrig, Rebecca
    Dixon, Robert
    Payne, Thomas
    Morin, Richard L.
    Ganguly, Arundhuti
    Strobel, Norbert
    MEDICAL PHYSICS, 2006, 33 (12) : 4541 - 4550
  • [23] Localizing spherical fiducials in C-arm based cone-beam CT
    Yaniv, Ziv
    MEDICAL PHYSICS, 2009, 36 (11) : 4957 - 4966
  • [24] Geometric calibration of a mobile C-arm for intraoperative cone-beam CT
    Daly, M. J.
    Siewerdsen, J. H.
    Cho, Y. B.
    Jaffray, D. A.
    Irish, J. C.
    MEDICAL PHYSICS, 2008, 35 (05) : 2124 - 2136
  • [25] Range Imaging for Motion Compensation in C-Arm Cone-Beam CT of Knees under Weight-Bearing Conditions
    Bier, Bastian
    Ravikumar, Nishant
    Unberath, Mathias
    Levenston, Marc
    Gold, Garry
    Fahrig, Rebecca
    Maier, Andreas
    JOURNAL OF IMAGING, 2018, 4 (01)
  • [26] C-arm fluoroscopic cone-beam CT for guidance of chemical thoracic sympathectomy
    Hirose, Munetaka
    Tabata, Mari
    Sakai, Mikako
    Takeuchi, Kenji
    JOURNAL OF ANESTHESIA, 2011, 25 (01) : 142 - 143
  • [27] C-arm orbits for metal artifact avoidance (MAA) in cone-beam CT
    Wu, P.
    Sheth, N.
    Sisniega, A.
    Uneri, A.
    Han, R.
    Vijayan, R.
    Vagdargi, P.
    Kreher, B.
    Kunze, H.
    Kleinszig, G.
    Vogt, S.
    Lo, S-F
    Theodore, N.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (16):
  • [28] Geometric calibration of an extended view C-arm platform for cone-beam CT
    Cho, Y
    Kim, S
    Siewerdsen, J
    Moseley, D
    Jaffray, D
    MEDICAL PHYSICS, 2005, 32 (06) : 1937 - 1937
  • [29] C-arm fluoroscopic cone-beam CT for guidance of chemical thoracic sympathectomy
    Munetaka Hirose
    Mari Tabata
    Mikako Sakai
    Kenji Takeuchi
    Journal of Anesthesia, 2011, 25 : 142 - 143
  • [30] Evaluation of Effective Dose During Neuro 3-D Imaging Using a C-Arm Cone-Beam CT System
    Wang, C.
    Ferrell, A.
    Nguyen, G.
    Toncheva, G.
    Jiang, X.
    Haynes, W.
    Enterline, D.
    Smith, T.
    Yoshizumi, T.
    MEDICAL PHYSICS, 2012, 39 (06) : 3620 - 3620