Human ex vivo bone tissue strains around immediately loaded implants supporting maxillary overdentures

被引:16
|
作者
Akça, K
Akkocaoglu, M
Cömert, A
Tekdemir, I
Çehreli, MC
机构
[1] Hacettepe Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
[2] Hacettepe Univ, Fac Dent, Dept Oral Surg, Ankara, Turkey
[3] Ankara Univ, Fac Med, Dept Anat, TR-06100 Ankara, Turkey
关键词
biomechanics; bone strain; immediate loading; installation torque; maxilla; overdenture; removal torque; resonance frequency analysis;
D O I
10.1111/j.1600-0501.2005.01176.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate ex vivo bone tissue strains around maxillary implants supporting immediately loaded bar-retained overdentures. Material and methods: Ninety degree two-element rosette strain gauges were bonded on the labial bone of four ITI (R) dental implants placed in the maxillary anterior region of four completely edentulous maxilla of fresh human cadavers. The installation torque value (ITV) of each implant was measured by a custom-made torque wrench and resonance frequency analyses (RFAs) were undertaken. A bar-retained overdenture was fabricated for each cadaver, and two miniature load cells were integrated in the first molar region of the overdentures for controlled loading experiments. Strain measurements were performed at a sample rate of 10 kHz and under a maximum load of 100 N, simultaneously monitored from a computer connected to a data acquisition system. Finally, removal torque values (RTVs) of the implants were measured. Results: RFA values did not mirror ITVs, while RTVs of implants were slightly lower than the ITVs. Any correlation could not be obtained between RFA values and ITVs or RTVs. Maximum strains around loaded implants ranged between -100 and -550 mu epsilon under 25-100 N. The axial and lateral strain values of posterior implants of both sides were higher than those of anterior implants under all loads (P < 0.05). Conclusion: Because occlusal forces in humans tend to decrease because of age-related factors, maximum strains around immediately loaded implants supporting maxillary overdentures fall within physiologic levels.
引用
收藏
页码:715 / 722
页数:8
相关论文
共 50 条
  • [41] The histological behaviour of bone tissue and mucous membranes in Italian school immediately loaded "one-piece" implants
    Pasqualini, M. E.
    Rossi, F.
    Dal Carlo, L.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2022, 36 (02): : 183 - 187
  • [42] In vivo forces on oral implants supporting mandibular overdentures and the effect on the peri-implant bone: a prospective clinical study.
    De Smet, E
    Duyck, J
    Van Steenberghe, D
    Jabocs, R
    Naert, I
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A437 - A437
  • [43] A Radiographic Review of Bone Levels Around Calcitek Dental Implants Supporting Mandibular Overdentures. Preliminary Results at 3 to 6 Years
    Patsiatzi, E.
    Malden, N.
    Ibbetson, R.
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2006, 14 (04): : 169 - 173
  • [44] Design and testing of an autonomous computer controlled loading device to study tissue adaptation around immediately loaded implants in the reindeer antler
    Rahimi, Alireza
    Abboud, Marcus
    Wahl, Gerhard
    Keilig, Ludger
    Hensch, Ingo
    Bourauel, Christoph
    ADVANCES IN MEDICAL ENGINEERING, 2007, 114 : 285 - +
  • [45] Biologic Width and Morphologic Characteristics of Soft Tissues Around Immediately Loaded Implants: Studies Performed on Human Autopsy Specimens
    Romanos, George E.
    Traini, Tonino
    Johansson, Carina B.
    Plattelli, Adriano
    JOURNAL OF PERIODONTOLOGY, 2010, 81 (01) : 70 - 78
  • [46] The Effect of Maximum Bite Force, Implant Number, and Attachment Type on Marginal Bone Loss around Implants Supporting Mandibular Overdentures: A Retrospective Study
    Geckili, Onur
    Mumcu, Emre
    Bilhan, Hakan
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 : e91 - e97
  • [47] Bone strains around apically free versus grafted implants in the posterior maxilla of human cadavers
    Cehreli, Murat Cavit
    Akkocaoglu, Murat
    Comert, Ayhan
    Tekdemir, Ibrahim
    Akca, Kivanc
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2007, 45 (04) : 395 - 402
  • [48] Ex vivo loading of trussed implants for spine fusion induces heterogeneous strains consistent with homeostatic bone mechanobiology
    Caffrey, Jason P.
    Cory, Esther
    Wong, Van W.
    Masuda, Koichi
    Chen, Albert C.
    Hunt, Jessee P.
    Ganey, Timothy M.
    Sah, Robert L.
    JOURNAL OF BIOMECHANICS, 2016, 49 (16) : 4090 - 4097
  • [49] Bone strains around apically free versus grafted implants in the posterior maxilla of human cadavers
    Murat Cavit Cehreli
    Murat Akkocaoglu
    Ayhan Comert
    Ibrahim Tekdemir
    Kivanc Akca
    Medical & Biological Engineering & Computing, 2007, 45 : 395 - 402
  • [50] Numerical investigation of bone remodelling around immediately loaded dental implants using sika deer (Cervus nippon) antlers as implant bed
    He, Yun
    Hasan, Istabrak
    Keilig, Ludger
    Fischer, Dominik
    Ziegler, Luisa
    Abboud, Marcus
    Wahl, Gerhard
    Bourauel, Christoph
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2018, 21 (04) : 359 - 369