Data Center Design Using Improved CFD Modeling and Cost Reduction Analysis

被引:0
|
作者
Mikjaniec, Travis [1 ]
Manning, Andy [1 ]
Small, Derrick [1 ]
VanGilder, Jim [2 ]
机构
[1] Mentor Graph Corp, 46871 Bayside Pkwy, Fremont, CA 94538 USA
[2] American Power Convers Corp, Billerica, MA 01862 USA
关键词
Computational Fluid Dynamics; Data Center; Thermal Analysis;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper will describe two recent advances in Computational Fluid Dynamics (CFD) modeling as it pertains to data center design. In particular, the paper will define the use of the Capture Index (CI) in data center analysis, and will discuss the importance of accurately modeling coolers. Secondly, the article will describe Mentor Graphics' own $30M data center project currently in development. Two new centralized data centers will consolidate the resources of more than 20 local data centers in Europe and North America. One will be built in Shannon, Ireland, and another in Wilsonville, Oregon. By consolidating data centers, Mentor will see gains in capacity, efficiency, and redundancy while reducing operational costs.
引用
收藏
页码:97 / 103
页数:7
相关论文
共 50 条
  • [31] On the feasibility of using conceptual modeling constructs for the design and analysis of XML data
    Sengupta, Arijit
    DATA & KNOWLEDGE ENGINEERING, 2012, 72 : 219 - 238
  • [32] CFD MODELING OF SUBSEA GAS RELEASES USING AN IMPROVED BUBBLE DRAG LAW
    Kara, Mustafa C.
    Parsi, Mazdak
    Jatale, Anchal
    Sharma, Partha P.
    PROCEEDINGS OF THE ASME 36TH INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, 2017, VOL 2, 2017,
  • [33] COST-EFFECTIVE METHOD FOR REDUCTION AND ANALYSIS OF FILM DATA USING PLATO SYSTEM
    FRANCIS, PR
    BOYSEN, JP
    JOURNAL OF BIOMECHANICS, 1978, 11 (6-7) : 343 - 345
  • [34] Cloud data center cost management using virtual machine consolidation with an improved artificial feeding birds algorithm
    Naeen, Mohammad Ali Monshizadeh
    Ghaffari, Hamid Reza
    Naeen, Hossein Monshizadeh
    COMPUTING, 2024, 106 (06) : 1795 - 1823
  • [35] Design and Operational Analysis of a Green Data Center
    Sharma, Prateek
    Pegus, Patrick, II
    Irwin, David
    Shenoy, Prashant
    Goodhue, John
    Culbert, James
    IEEE INTERNET COMPUTING, 2017, 21 (04) : 16 - 24
  • [36] Partnership Between a Cancer Center and Payer: Opportunities for Improved Quality of Care and Cost Reduction
    Shulman, Lawrence N.
    Mamon, Harvey
    Jacobson, Joseph O.
    Steingisser, Lee
    Dodek, Anton
    Fallon, John A.
    JOURNAL OF ONCOLOGY PRACTICE, 2013, 9 (03) : 133 - 134
  • [37] Using CFD for a Sensitivity Analysis of Stent Design Parameters
    Stiehm, M.
    Brede, M.
    Quosdorf, D.
    Martin, H.
    Schmitz, K-P
    Leder, A.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S888 - +
  • [38] A Sensitivity Analysis of Stent Design Parameters using CFD
    Stiehm, M.
    Brede, M.
    Quosdorf, D.
    Martin, H.
    Leder, A.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58
  • [39] Optical data center switches design and analysis
    Nigam A.
    Mishra B.
    Patel P.
    Journal of Optical Communications, 2023, 44 (s1) : S409 - S417
  • [40] DCSim: Design analysis on Virtualization Data Center
    Chen, Chia-Jung
    Liu, Yi-Sheng
    Chang, Rong-Guey
    2012 9TH INTERNATIONAL CONFERENCE ON UBIQUITOUS INTELLIGENCE & COMPUTING AND 9TH INTERNATIONAL CONFERENCE ON AUTONOMIC & TRUSTED COMPUTING (UIC/ATC), 2012, : 900 - 905