Microwave Doppler transducer for contactless cardiorespiratory monitoring

被引:0
|
作者
Tipa, R. S. [1 ]
Baltag, O. I. [2 ]
机构
[1] Alexandru Ioan Cuza Univ, Fac Phys, Iasi, Romania
[2] Univ Med & Pharm Gr T Popa, Fac Biomed Engn, Iasi, Romania
来源
ROMANIAN JOURNAL OF PHYSICS | 2008年 / 53卷 / 1-2期
关键词
microwaves Doppler transducer; contact less detection; cardiorespiratory activity;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
One presents the results of a study concerning the use of microwave Doppler transducer for contact-less detection of cardiorespiratory activity. The main element of the installation is a microwave Doppler transducer. The Doppler signal resulting from the movement of the anatomical structures is a complex one. The experimental setup also includes an electrocardiograph, a photopletismograph and a pneumatic sensor attached to the thorax to detect breathing motions. At the same time, two types of breathing were identified: the thoracic and the abdominal ones. A good correlation was noticed between the ECG signal and the Doppler signal.
引用
收藏
页码:339 / 342
页数:8
相关论文
共 50 条
  • [21] CARDIORESPIRATORY MONITORING
    HUNT, CE
    CLINICS IN PERINATOLOGY, 1991, 18 (03) : 473 - 495
  • [22] MONITORING VARIATIONS OF BIOLOGICAL IMPEDANCES USING MICROWAVE DOPPLER RADAR
    THANSANDOTE, A
    STUCHLY, SS
    SMITH, AM
    PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (08): : 983 - 990
  • [23] Noncontact Respiration Monitoring During Sleep With Microwave Doppler Radar
    Zakrzewski, Mari
    Vehkaoja, Antti
    Joutsen, Atte S.
    Palovuori, Karri T.
    Vanhala, Jukka J.
    IEEE SENSORS JOURNAL, 2015, 15 (10) : 5683 - 5693
  • [24] Microwave Doppler Radar for Monitoring of Vital Sign and Rotational Movement
    Sadhukhan, Soumya
    Paul, Shubhadip
    Akhtar, M. Jaleel
    2021 IEEE ASIA-PACIFIC MICROWAVE CONFERENCE (APMC), 2021, : 61 - 63
  • [25] Monitoring and Analysis of Respiratory Patterns Using Microwave Doppler Radar
    Lee, Yee Siong
    Pathirana, Pubudu N.
    Steinfort, Christopher Louis
    Caelli, Terry
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2014, 2
  • [26] Monitoring and Analysis of Respiratory Patterns Using Microwave Doppler Radar
    Lee, Yee Siong
    Pathirana, Pubudu N.
    Steinfort, Christopher Louis
    Caelli, Terry
    IEEE Journal of Translational Engineering in Health and Medicine, 2014, 2
  • [27] Contactless Encoder Based on the Doppler Effect
    Karlova, G. F.
    Avdochenko, B. I.
    Yegunov, M. S.
    Belozerova, E. A.
    RUSSIAN PHYSICS JOURNAL, 2023, 66 (06) : 689 - 694
  • [28] Contactless Encoder Based on the Doppler Effect
    G. F. Karlova
    B. I. Avdochenko
    M. S. Yegunov
    E. A. Belozerova
    Russian Physics Journal, 2023, 66 : 689 - 694
  • [29] Microwave contactless vibrotransducer of displacements
    Nikitin, A.A.
    Zasorin, V.A.
    Tyazheloe Mashinostroenie, 2001, (09): : 5 - 6
  • [30] CONTACTLESS MONITORING OF Si SUBSTRATE PERMITTIVITY AND RESISTIVITY FROM MICROWAVE TO MILLIMETER WAVE FREQUENCIES
    Elhawil, A.
    Neve, C. Roda
    Olbrechts, B.
    Huynen, I.
    Raskin, J. -P.
    Poesen, G.
    Stiens, J.
    Vounckx, R.
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2010, 52 (11) : 2500 - 2505