High-energy neutron depth-dose distribution experiment

被引:0
|
作者
Ferenci, MS
Hertel, NE
机构
[1] Georgia Inst Technol, Neely Nucl Res Ctr, Atlanta, GA 30332 USA
[2] Emory Univ, Dept Radiat Oncol, Atlanta, GA 30322 USA
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A unique set of high-energy neutron depth-dose benchmark experiments were performed at the Los Alamos Neutron Science Center/Weapons Neutron Research (LANSCE/WNR) complex. The experiments consisted of filtered neutron beams with energies up to 800 MeV impinging on a 30 x 30 x 30 cm(3) liquid. tissue-equivalent phantom. The absorbed dose was measured in the phantom at various depths with tissue-equivalent ion chambers. This experiment is intended to serve as a benchmark experiment for the testing of high-energy radiation transport codes for the international radiation protection community.
引用
收藏
页码:213 / 224
页数:12
相关论文
共 50 条
  • [11] Calculation of depth-dose distribution of intermediate energy heavy-ion beam
    Kao Neng Wu Li Yu Ho Wu Li/High Energy Physics and Nuclear Physics, 2000, 24 (05): : 414 - 417
  • [12] Calculation of depth-dose distribution of intermediate energy heavy-ion beams
    Li, Q
    Wei, ZQ
    Li, WJ
    CHINESE SCIENCE BULLETIN, 2002, 47 (20): : 1708 - 1710
  • [13] Calculation of depth-dose distribution of intermediate energy heavy-ion beam
    Li, Q
    Wei, ZQ
    Li, WJ
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2000, 24 (05): : 414 - 417
  • [14] DISTRIBUTION OF THE DEPTH DOSE AND CROSSLINKING DENSITY IN POLYMERS IRRADIATED WITH HIGH-ENERGY ELECTRONS
    BALARIN, M
    HEINRICH, HJ
    ISOTOPENPRAXIS, 1979, 15 (2-3): : 29 - 37
  • [15] DEPTH-DOSE DISTRIBUTION MEASUREMENTS AND CALCULATIONS IN AN ELLIPTICAL PHANTOM
    PALFALVI, J
    KOBLINGER, L
    SZABO, PP
    HEALTH PHYSICS, 1983, 44 (01): : 35 - 44
  • [16] DEPTH-DOSE DISTRIBUTION FOR FISSION NEUTRON-SPECTRA DEGRADED THROUGH LOW Z SHIELDS
    SINGH, D
    BISHT, JS
    MADHVANATH, U
    NUCLEAR INSTRUMENTS & METHODS, 1979, 159 (01): : 229 - 234
  • [17] COMPUTATION OF PION DEPTH-DOSE CURVES IN WATER AND COMPARISON WITH EXPERIMENT
    TURNER, JE
    SELTZER, SM
    WRIGHT, HA
    SULLIVAN, AH
    HAMM, RN
    BERGER, MJ
    BAARLI, J
    DUTRANNOIS, J
    RADIATION RESEARCH, 1972, 52 (02) : 229 - +
  • [18] Measurement of depth-dose distribution of protons by an imaging plate
    Nohtomi, A
    Sakae, T
    Terunuma, T
    Tsunashima, Y
    Hosono, K
    Hayakawa, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 511 (03): : 382 - 387
  • [19] ELECTRON DEPTH-DOSE DEPENDENCE ON ENERGY SPECTRAL QUALITY
    JOHNSEN, SW
    LARIVIERE, PD
    TANABE, E
    MEDICAL PHYSICS, 1982, 9 (05) : 803 - 803
  • [20] MEASUREMENT OF DEPTH-DOSE DISTRIBUTION IN ELECTRON IRRADIATED MATERIALS
    DAVIES, JM
    MCQUE, B
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1970, 21 (05): : 283 - &