Comparison of the anterior ocular segment measurements using swept-source optical coherent tomography and a scanning peripheral anterior chamber depth analyzer

被引:8
|
作者
Furuya, Toshie [1 ]
Mabuchi, Fumihiko [1 ]
Chiba, Tatsuya [1 ]
Kogure, Satoshi [2 ]
Tsukahara, Shigeo [1 ]
Kashiwagi, Kenji [1 ,3 ]
机构
[1] Univ Yamanashi, Sch Med & Engn, Dept Ophthalmol Interdisciplinary, Chuo Ku, Yamanashi, Japan
[2] Kogure Eye Clin, Showa Ku, Yamanashi, Japan
[3] Univ Yamanashi, Interdisciplinary Sch Med & Engn, Dept Community & Family Med, Chuo Ku, Yamanashi, Japan
关键词
Anterior chamber depth; Corneal thickness; Optical coherent tomography; Angle openness; Glaucoma; PRIMARY ANGLE-CLOSURE; CENTRAL CORNEAL THICKNESS; SLIT-LAMP OCT; ULTRASOUND BIOMICROSCOPY; GLAUCOMA; EYE; POPULATION; IOLMASTER; DIAMETER; PENTACAM;
D O I
10.1007/s10384-011-0071-x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To compare the anterior ocular segment measurements of two non-contact devices, i.e., anterior segment swept-source optical coherence tomography (SS-OCT) and the scanning peripheral anterior chamber depth analyzer (SPAC), in patients with glaucoma. This was a cross-sectional study of glaucoma patients visiting the Yamanashi University Hospital. The consistency and correlation of various parameters were studied between the SS-OCT and SPAC measurements, including the central corneal thickness (CCT), the central anterior chamber depth (ACD), the trabecular-iris angle (TIA), the angle opening distance (AOD), the area of the recessed angle (ARA), and the trabecular-iris space area (TISA) from the SS-OCT measurements, and the CCT, central ACD, SPAC grade, and SPAC-evaluated anterior chamber angle (ACA) from the SPAC measurements. Seventy right eyes of 70 patients (27 men, 43 women) with glaucoma were enrolled in the study. The mean patient age was 65.9 +/- A 14.5 years. The CCT measurements by SS-OCT and the SPAC were 528.3 +/- A 32.0 and 516.1 +/- A 28.5 mu m, respectively (P < 0.001). The central ACD measurements by SS-OCT and the SPAC were 2.39 +/- A 0.44 and 2.73 +/- A 0.50 mm, respectively (P < 0.001). The two devices showed a significant correlation in terms of the CCT measurements (R (2) = 0.667, P < 0.0001) and the central ACD measurements (R (2) = 0.86, P < 0.0001), but SS-OCT give a significantly shallower central ACD measurement and a thinner CCT measurement compared with the SPAC. AOD, TIA, TISA, and the ARA were all significantly correlated with the SPAC grade and the ACA. Consistency between the two devices was reduced among eyes with primary angle closure. Based on our results, the SS-OCT and SPAC measurements of the anterior segment were significantly correlated, but the values cannot be considered to be directly interchangeable.
引用
收藏
页码:472 / 479
页数:8
相关论文
共 50 条
  • [41] Measurement of Iris Lesion Volume with Anterior Segment Swept-Source Optical Coherence Tomography
    Vickers, Laura
    Akil, Handan
    Baghdasaryan, Elmira
    Lee, Olivia L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [42] Effects of 0.01% Atropine Instillation Assessed Using Swept-Source Anterior Segment Optical Coherence Tomography
    Mitsukawa, Tadahiro
    Suzuki, Yumi
    Momota, Yosuke
    Suzuki, Shun
    Yamada, Masakazu
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (19)
  • [43] Objective quantification of lens nuclear opacities using swept-source anterior segment optical coherence tomography
    Wang, Wei
    Zhang, Jiaqing
    Gu, Xiaoxun
    Ruan, Xiaoting
    Chen, Xiaoyun
    Tan, Xuhua
    Jin, Guangming
    Wang, Lanhua
    He, Mingguang
    Congdon, Nathan
    Liu, Zhenzhen
    Luo, Lixia
    Liu, Yizhi
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2022, 106 (06) : 790 - 794
  • [44] Screening for Subclinical Keratoconus Using Swept-Source Fourier Domain Anterior Segment Optical Coherence Tomography
    Steinberg, Johannes
    Casagrande, Maria K.
    Frings, Andreas
    Katz, Toam
    Druchkiv, Vasyl
    Richard, Gisbert
    Linke, Stephan J.
    CORNEA, 2015, 34 (11) : 1413 - 1419
  • [45] Comparison of Slitlamp Optical Coherence Tomography and Scanning Peripheral Anterior Chamber Depth Analyzer to Evaluate Angle Closure in Asian Eyes
    Wong, Hon-Tym
    Chua, Jocelyn L. L.
    Sakata, Lisandro M.
    Wong, Melissa H. Y.
    Aung, Han T.
    Aung, Tin
    ARCHIVES OF OPHTHALMOLOGY, 2009, 127 (05) : 599 - 603
  • [46] Comparison of a New Swept-Source Anterior Segment Optical Coherence Tomography and a Scheimpflug Camera for Measurement of Corneal Curvature
    Zhang, Ting
    Zhou, Yijing
    Young, Charlotte Aimee
    Chen, Aiming
    Jin, Guangming
    Zheng, Danying
    CORNEA, 2020, 39 (07) : 818 - 822
  • [47] Measurements of corneal astigmatism axis with anterior segment swept source optical coherent tomography versus auto refractokearatometer
    Nakano, Shinichiro
    Iida, Masaharu
    Hiraoka, Takahiro
    Oshika, Tetsuro
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [48] Intradevice Repeatability and Interdevice Agreement of Ocular Biometric Measurements: A Comparison of Two Swept-Source Anterior Segment OCT Devices
    Pardeshi, Anmol A.
    Song, Abe E.
    Lazkani, Naim
    Xie, Xiaobin
    Huang, Alex
    Xu, Benjamin Y.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (09): : 1 - 9
  • [49] Observation of anterior chamber volume after cataract surgery with swept-source optical coherence tomography
    Chen, Minjie
    Hu, Hailin
    He, Wenwen
    Lu, Yi
    Zhu, Xiangjia
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (08) : 1837 - 1844
  • [50] Reference values for anterior chamber morphometrics with swept-source optical coherence tomography in a Caucasian population
    Romkens, Hellen C. S.
    Beckers, Henny J. M.
    Schouten, Jan S. A. G.
    Berendschot, Tos T. J. M.
    Webers, Carroll A. B.
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 411 - 417