Reduction in flow artifacts by using interleaved data acquisition in segmented balanced steady-state free precession cardiac MRI

被引:3
|
作者
Amano, Y
Nozaki, A
Takahama, K
Kumazaki, T
机构
[1] Nippon Med Coll, Dept Radiol, Bunkyo Ku, Tokyo 1138603, Japan
[2] GE Yokogawa Med Syst, Tokyo, Japan
关键词
magnetic resonance imaging; heart; steady-state free precession; interleaved data acquisition; flow artifact;
D O I
10.1016/j.compmedimag.2005.02.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Balanced steady-state free precession (SSFP) magnetic resonance (MR) imaging is feasible for cine cardiac images because of the high contrast between myocardium and blood pool and robustness to rapid blood flow. Nonetheless, the flow artifacts are often observed because of off-resonance effects and to in-flow effects of the blood flow. Although reshimming the gradients or readjusting the center frequency reduces the artifacts, the technique can be susceptible for respiratory and cardiac motion and operator-dependent. The purpose of this study is to use another MR imaging technique for the reduction in the flow artifacts in the heart: odd-even interleaved data acquisition in segmented balanced SSFP imaging. The flow artifacts in the ventricle, ghost outside the heart, and visualization of the myocardial border were visually compared between sequential and odd-even interleaved k-space data acquisitions in cine balanced SSFP cardiac MR imaging. The odd-even interleaved k-space data acquisition significantly reduced dark flow artifacts in the left ventricle, improved the visualization of the myocardial border, and was easily installed. This imaging technique should be applied to cine segmented balanced SSFP cardiac MR imaging. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:441 / 445
页数:5
相关论文
共 50 条
  • [31] Physiological and Functional Magnetic Resonance Imaging Using Balanced Steady-state Free Precession
    Park, Sung-Hong
    Han, Paul Kyu
    Choi, Seung Hong
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (03) : 550 - 559
  • [32] Concomitant gradient field effects in balanced steady-state free precession
    Sica, Christopher T.
    Meyer, Craig H.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (04) : 721 - 730
  • [33] Pure balanced steady-state free precession imaging (pure bSSFP)
    Schaeper, Jessica
    Bauman, Grzegorz
    Ganter, Carl
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (04) : 1886 - 1893
  • [34] Motion resilience of the balanced steady-state free precession geometric solution
    Hoff, Michael N.
    Xiang, Qing-San
    Cross, Nathan M.
    Hippe, Daniel
    Andre, Jalal B.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (01) : 192 - 204
  • [35] Optimized balanced steady-state free precession magnetization transfer Imaging
    Bieri, O.
    Scheffler, K.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (03) : 511 - 518
  • [36] Multiple Repetition Time Balanced Steady-State Free Precession Imaging
    Cukur, Tolga
    Nishimura, Dwight G.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) : 193 - 204
  • [37] Assessment of Small Bowel Motility Function With Cine-MRI Using Balanced Steady-State Free Precession Sequence
    Wakamiya, Makoto
    Furukawa, Akira
    Kanasaki, Shuzo
    Murata, Kiyoshi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (05) : 1235 - 1240
  • [38] In vivo bone and cartilage MRI using fully-balanced steady-state free-precession at 7 Tesla
    Krug, Roland
    Carballido-Gamio, Julio
    Banerjee, Suchandrima
    Stahl, Robert
    Carvajal, Lucas
    Xu, Duan
    Vigneron, Dan
    Kelley, Douglas A. C.
    Link, Thomas M.
    Majumdar, Sharmila
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) : 1294 - 1298
  • [39] Assessment of Magnetization Transfer Effects in Myocardial Tissue Using Balanced Steady-State Free Precession (bSSFP) Cine MRI
    Weber, Oliver M.
    Speier, Peter
    Scheffler, Klaus
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (03) : 699 - 705
  • [40] Improved In-Stent Lumen Visualization using Intravascular MRI and a Balanced Steady-State Free-Precession Sequence
    Gilbert, Guillaume
    Soulez, Gilles
    Beaudoin, Gilles
    ACADEMIC RADIOLOGY, 2009, 16 (12) : 1466 - 1474