Template synthesis of the Cu2O nanoparticle-doped hollow carbon nanofibres and their application as non-enzymatic glucose biosensors

被引:7
|
作者
Li, Yingjie [1 ]
Cai, Renhao [1 ]
Lu, Renjiang [1 ]
Gao, Lidi [1 ]
Qin, Shili [1 ]
机构
[1] Qiqihar Univ, Coll Chem & Chem Engn, Qiqihar, Heilongjiang, Peoples R China
来源
ROYAL SOCIETY OPEN SCIENCE | 2018年 / 5卷 / 12期
关键词
template synthesis; Cu2O nanopartides; doped; hollow carbon nanofibres; biosensors; ANODE MATERIALS; NANOTUBES; NANOCOMPOSITES; PERFORMANCE; WATER; OXIDE; ADSORPTION; REDUCTION; COMPOSITE; BENZENE;
D O I
10.1098/rsos.181474
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The cuprous oxide nanoparticle (Cu2ONP)-doped hollow carbon nanofibres (Cu2O/HCFs) were directly synthesized by the anodic aluminium oxide (AAO) template. The doped Cu2O NPs were formed by in situ deposition by direct reduction reaction of precursor carbonization in thermal decomposition and could act as functionalized nanoparticles. The synthesized Cu2O/HCFs were characterized in detail by transmission electron microscopy (TEM), scanning electron microscopy (SEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Raman spectroscopy and inductively coupled plasma mass spectrometry (ICP-MS). The results reveal that Cu2O/HCFs have a tubular structure with an average diameter of approximately 60 nm. The shape of the Cu2O/HCFs is straight and Cu2O NPs are uniformly distributed and highly dispersed in HCFs. Cu2O/HCFs have good dispersibility. The electrochemical activity of Cu2O/HCFs was investigated by cyclic voltammetry (CV), the glucose sensors display high electrochemical activity towards the oxidation of glucose. Cu2O/HCFs can effectively accelerate the transmission of electrons on the electrode surface. Cu2O/HCFs are applied in the detection of glucose with a detection limit of 0.48 mu M, a linear detection range from 7.99 to 33.33 mu M and with a high sensitivity of 1218.3 mu A cm(-2) mM(-1). Moreover, the experimental results demonstrate that Cu2O/HCFs have good stability, reproducibility and selectivity. Our results suggest that Cu2O/HCFs could be a promising candidate for the construction of non-enzymatic sensor.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Solvothermal synthesis of Cu/Cu2O hollow microspheres for non-enzymatic amperometric glucose sensing
    Wang, Ai-Jun
    Feng, Jiu-Ju
    Li, Zhong-Hua
    Liao, Qi-Chen
    Wang, Zhen-Zhen
    Chen, Jian-Rong
    CRYSTENGCOMM, 2012, 14 (04): : 1289 - 1295
  • [2] Mesocrystalline Cu2O hollow nanocubes: synthesis and application in non-enzymatic amperometric detection of hydrogen peroxide and glucose
    Gao, Zhiyong
    Liu, Junli
    Chang, Jiuli
    Wu, Dapeng
    He, Jinjin
    Wang, Kui
    Xu, Fang
    Jiang, Kai
    CRYSTENGCOMM, 2012, 14 (20): : 6639 - 6646
  • [3] A controllable synthesis of hollow pumpkin-like CuO/Cu2O composites for ultrasensitive non-enzymatic glucose and hydrogen peroxide biosensors
    Ma, Xiaoqing
    Tang, Kang-lai
    Yang, Mingyu
    Shi, Wenbing
    Zhao, Wenxi
    NEW JOURNAL OF CHEMISTRY, 2020, 44 (46) : 20411 - 20418
  • [4] Facile synthesis of uniform CuO/Cu2O composite hollow microspheres for a non-enzymatic glucose sensor
    Zhang, Fan
    Xiao, Xin
    Wang, Jie
    Huang, Shan
    Zhang, Hao
    Zhang, Weidong
    Guo, Xi
    Zhang, Dongen
    Wang, Mingyan
    MATERIALS RESEARCH EXPRESS, 2019, 6 (11)
  • [5] Cu2O hollow microspheres as electrode materials for non-enzymatic electrochemical detection of glucose
    Zhang, Fan
    Wang, Yihui
    Wu, Xiujuan
    Zhang, Hao
    Huang, Shan
    Yang, Ying
    Xie, Adi
    Wang, Mingyan
    MICRO & NANO LETTERS, 2020, 15 (15) : 1071 - 1074
  • [6] Cu2O ordered nanoarrays for non-enzymatic glucose detection
    Liu, Chenchen
    Xue, Kaifeng
    Sun, Aixin
    Chen, Dexiang
    Zhang, Pinhua
    Cui, Guangliang
    JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2021, 24 (06): : 829 - 835
  • [7] Study of the application of a Cu2O thin film as non-enzymatic amperometric glucose sensor
    Figueredo, Francisco
    Henriquez, Rodrigo
    Munoz, Eduardo
    Heyser, Cristopher
    Schrebler, Ricardo
    Grez, Paula
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2024, 971
  • [8] The dependence of Cu2O morphology on different surfactants and its application for non-enzymatic glucose detection
    Liu, Wenbin
    Guo, Qing
    Zhao, Xingming
    Zhang, Bowen
    Wang, Mingguang
    Dai, Yuxiang
    Qi, Yang
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2021, 208
  • [9] Synthesis of Cu2O on AlOOH/reduced graphene oxide for non-enzymatic amperometric glucose sensing
    Yang, Ziyin
    Yan, Xiaoqin
    Li, Zhi
    Zheng, Xiaohui
    Zheng, Jianbin
    ANALYTICAL METHODS, 2016, 8 (07) : 1527 - 1531
  • [10] Hierarchical hollow CuO/Cu2O and Cu2O/Cu/C derived from metal- organic framework for non-enzymatic oxidation toward glucose
    Chen, Huan
    Shao, Lei
    Ma, Junchao
    He, Wenxiu
    Zhang, Bing
    Zhai, Xu
    Fu, Yu
    JOURNAL OF MOLECULAR LIQUIDS, 2023, 375