Study of the application of a Cu2O thin film as non-enzymatic amperometric glucose sensor

被引:0
|
作者
Figueredo, Francisco [1 ]
Henriquez, Rodrigo [1 ]
Munoz, Eduardo [1 ]
Heyser, Cristopher [2 ]
Schrebler, Ricardo [1 ]
Grez, Paula [1 ]
机构
[1] Pontificia Univ Catolica Valparaiso, Lab Electroquim, Inst Quim, Fac Ciencias, Ave Univ 330, Valparaiso 2373223, Chile
[2] Univ La Frontera, Dept Ciencias Quim & Recursos Nat, Fac Ingn & Ciencias, Ave Francisco Salazar 01145, Temuco, Chile
关键词
Non-enzymatic amperometric sensor; Glucose; Cu2O thin film; DIABETES-MELLITUS; PERFORMANCE; COPPER;
D O I
10.1016/j.jelechem.2024.118584
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The detection and control of glucose (Glu) levels in both food and biological samples have gained importance in recent decades, as imbalances in glucose levels can lead to health complications such as diabetes mellitus. Consequently, this study focused on synthesizing thin films of Cu2O and evaluating their application as a non-enzymatic amperometric glucose sensor. The Cu2O films were obtained on FTO at a constant potential (-0.575 V vs. SMSE), in an inert atmosphere and at room temperature. The electrolyte solution consisted of 0.02 M of copper acetate (Cu(OOCCH3)(2)) and 0.1 M of sodium acetate (NaOOCCH3) at pH 5.79, in a three-electrode cell. The films obtained were analyzed by scanning electron microscopy (SEM) and X-ray diffraction (XRD). On the other hand, the electrocatalytic activity was studied using linear potential sweep (LPS) and chronoamperometry (CA) techniques. From these techniques, it was possible to determine the sensitivity (228.1 mu A mM(-1) cm(-2)), limit of detection (LOD 2.49 x 10(-3) mM), limit of quantification (LOQ 7.54 x 10(-3) mM) and linear range (0.10 mM <=[Glucose] <= 15 mM). In this concentration interval the response time was between 1.4 and 14 s. It was established that the sensor exhibits minimal response to various electroactive interferences and demonstrates reproducibility and stability over time. In this way, the proposed Cu2O electrode is a good candidate to be used as a non-enzymatic amperometric glucose sensor.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Solvothermal synthesis of Cu/Cu2O hollow microspheres for non-enzymatic amperometric glucose sensing
    Wang, Ai-Jun
    Feng, Jiu-Ju
    Li, Zhong-Hua
    Liao, Qi-Chen
    Wang, Zhen-Zhen
    Chen, Jian-Rong
    [J]. CRYSTENGCOMM, 2012, 14 (04): : 1289 - 1295
  • [2] Carbon quantum dots/octahedral Cu2O nanocomposites for non-enzymatic glucose and hydrogen peroxide amperometric sensor
    Li, Yancai
    Zhong, Yanmei
    Zhang, Yayun
    Weng, Wen
    Li, Shunxing
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 206 : 735 - 743
  • [3] Mesocrystalline Cu2O hollow nanocubes: synthesis and application in non-enzymatic amperometric detection of hydrogen peroxide and glucose
    Gao, Zhiyong
    Liu, Junli
    Chang, Jiuli
    Wu, Dapeng
    He, Jinjin
    Wang, Kui
    Xu, Fang
    Jiang, Kai
    [J]. CRYSTENGCOMM, 2012, 14 (20): : 6639 - 6646
  • [4] Synthesis of Cu2O on AlOOH/reduced graphene oxide for non-enzymatic amperometric glucose sensing
    Yang, Ziyin
    Yan, Xiaoqin
    Li, Zhi
    Zheng, Xiaohui
    Zheng, Jianbin
    [J]. ANALYTICAL METHODS, 2016, 8 (07) : 1527 - 1531
  • [5] Cu2O ordered nanoarrays for non-enzymatic glucose detection
    Liu, Chenchen
    Xue, Kaifeng
    Sun, Aixin
    Chen, Dexiang
    Zhang, Pinhua
    Cui, Guangliang
    [J]. JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2021, 24 (06): : 829 - 835
  • [6] Preparation of three dimensional Cu2O/Au/GO hybrid electrodes and its application as a non-enzymatic glucose sensor
    Liu, Wenbin
    Zhao, Xingming
    Dai, Yuxiang
    Qi, Yang
    [J]. MICROCHEMICAL JOURNAL, 2022, 179
  • [7] Flower-like MoS2 decorated with Cu2O nanoparticles for non-enzymatic amperometric sensing of glucose
    Fang, Linxia
    Wang, Fan
    Chen, Zhenghua
    Qiu, Yan
    Zhai, Tianli
    Hu, Mengmeng
    Zhang, Cuijie
    Huang, Kejing
    [J]. TALANTA, 2017, 167 : 593 - 599
  • [8] The dependence of Cu2O morphology on different surfactants and its application for non-enzymatic glucose detection
    Liu, Wenbin
    Guo, Qing
    Zhao, Xingming
    Zhang, Bowen
    Wang, Mingguang
    Dai, Yuxiang
    Qi, Yang
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2021, 208
  • [9] Development of Cu2O/Carbon Vulcan XC-72 as non-enzymatic sensor for glucose determination
    El Khatib, K. M.
    Hameed, R. M. Abdel
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 26 (08): : 3542 - 3548
  • [10] Facile synthesis of uniform CuO/Cu2O composite hollow microspheres for a non-enzymatic glucose sensor
    Zhang, Fan
    Xiao, Xin
    Wang, Jie
    Huang, Shan
    Zhang, Hao
    Zhang, Weidong
    Guo, Xi
    Zhang, Dongen
    Wang, Mingyan
    [J]. MATERIALS RESEARCH EXPRESS, 2019, 6 (11)