Noise dosimeter for monitoring exposure to impulse noise

被引:12
|
作者
Kardous, CA
Willson, RD
Murphy, WJ
机构
[1] NIOSH, Hearing Loss Prevent Sect, Cincinnati, OH 45226 USA
[2] Beta Associates, Cincinnati, OH USA
关键词
impulse noise; noise dosimeter; new design;
D O I
10.1016/j.apacoust.2004.11.007
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Commercially available noise dosimeters do not perform properly in impulsive noise environments because they suffer from instrumentation limitations and lack metrics that characterize impulse noise. In this paper, a design concept is proposed for an impulse noise monitoring dosimeter that addresses the current dosimeter's limited capabilities and describes the various parameters that can appropriately be used to measure and evaluate exposure to impulse noise. The design concept is based on the accurate acquisition and storage of the original impulse waveform. For data analysis (using MATLAB) and calculation of "impulse noise metrics," National Institute for Occupational Safety and Health (NIOSH) used a prototype impulse noise dosimeter system that consisted of a Bruel&Kjaer 4136 microphone and a Panasonic Digital Audio Tape Recorder. The proposed instrument would enable collection of data for validation of presently defined and yet to be defined metrics quantifying noise-induced permanent threshold shifts (NIPTS) resulting from impulse/impact exposures. It will also enable occupational safety and health professionals to make accurate measurements of ultimately approved metrics. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:974 / 985
页数:12
相关论文
共 50 条
  • [41] Diagnostics of Impulse Noise
    Krejci, Jaroslav
    Zeman, Tomas
    TSP 2010: 33RD INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING, 2010, : 411 - 416
  • [42] DANGER OF IMPULSE NOISE
    MIKUCKI, S
    MECHANIK MIESIECZNIK NAUKOWO-TECHNICZNY, 1981, 54 (12): : 572 - 572
  • [43] THE MEASUREMENT OF IMPULSE NOISE
    KAMPERMAN, GW
    SOUND AND VIBRATION, 1980, 14 (03): : 5 - 5
  • [44] Analyze of Impulse Noise
    Krejci, Jaroslav
    Zeman, Tomas
    KNOWLEDGE IN TELECOMMUNICATION TECHNOLOGIES AND OPTICS 2010 (KTTO 2010), 2010, : 96 - 100
  • [45] Protection from continuous, impact, or impulse noise provided by prior exposure to low-level noise
    Henderson, D
    Subramaniam, M
    Henselman, LW
    Portalatini, P
    Spongr, VP
    Sallustio, V
    SCIENTIFIC BASIS OF NOISE-INDUCED HEARING LOSS, 1996, : 150 - 158
  • [46] PROBLEMS ASSOCIATED WITH REPRODUCTION OF IMPULSE NOISE FOR TTS STUDIES AND IMPULSE NOISE MEASUREMENTS
    WALKER, JG
    BEHAR, A
    JOURNAL OF SOUND AND VIBRATION, 1971, 19 (03) : 349 - &
  • [47] ADAPTING NOISE DOSIMETER TO EXTENDED WORKDAYS
    ATWOOD, DP
    KUNSNETZ, HL
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1975, 36 (11): : 858 - 859
  • [48] A Study On Impulse Noise Removal For Varied Noise Densities
    Radhika, V.
    Padmavathi, G.
    PROCEEDINGS OF THE FIRST AMRITA ACM-W CELEBRATION OF WOMEN IN COMPUTING IN INDIA (A2WIC), 2010,
  • [49] A variational method with a noise detector for impulse noise removal
    Chen, Shoushui
    Yang, Xin
    SCALE SPACE AND VARIATIONAL METHODS IN COMPUTER VISION, PROCEEDINGS, 2007, 4485 : 442 - +
  • [50] Assessment of mean auditory hazard incurred by occupational exposure to impulse noise
    Forget, P.