Noise dosimeter for monitoring exposure to impulse noise

被引:12
|
作者
Kardous, CA
Willson, RD
Murphy, WJ
机构
[1] NIOSH, Hearing Loss Prevent Sect, Cincinnati, OH 45226 USA
[2] Beta Associates, Cincinnati, OH USA
关键词
impulse noise; noise dosimeter; new design;
D O I
10.1016/j.apacoust.2004.11.007
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Commercially available noise dosimeters do not perform properly in impulsive noise environments because they suffer from instrumentation limitations and lack metrics that characterize impulse noise. In this paper, a design concept is proposed for an impulse noise monitoring dosimeter that addresses the current dosimeter's limited capabilities and describes the various parameters that can appropriately be used to measure and evaluate exposure to impulse noise. The design concept is based on the accurate acquisition and storage of the original impulse waveform. For data analysis (using MATLAB) and calculation of "impulse noise metrics," National Institute for Occupational Safety and Health (NIOSH) used a prototype impulse noise dosimeter system that consisted of a Bruel&Kjaer 4136 microphone and a Panasonic Digital Audio Tape Recorder. The proposed instrument would enable collection of data for validation of presently defined and yet to be defined metrics quantifying noise-induced permanent threshold shifts (NIPTS) resulting from impulse/impact exposures. It will also enable occupational safety and health professionals to make accurate measurements of ultimately approved metrics. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:974 / 985
页数:12
相关论文
共 50 条
  • [1] NOISE DOSIMETER FOR MEASURING PERSONAL NOISE EXPOSURE
    LAGERHOL.S
    TOREMALM, NG
    ACTA OTO-LARYNGOLOGICA, 1970, : 139 - &
  • [2] NECI - PERSONAL NOISE EXPOSURE DOSIMETER
    SULLIVAN, CE
    KNOWD, M
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1971, 50 (01): : 110 - &
  • [3] HAZARDOUS EXPOSURE TO IMPULSE NOISE
    COLES, RRA
    GARINTHER, GR
    HODGE, DC
    RICE, CG
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1968, 43 (02): : 336 - +
  • [4] Combined exposure to impulse noise and styrene
    Campo, Pierre
    Venet, Thomas
    Thomas, Aurelie
    Cour, Chantal
    Cosnier, Frederic
    NEUROTOXICOLOGY AND TERATOLOGY, 2015, 49 : 119 - 120
  • [5] EXPOSURE CONSIDERATIONS FOR IMPULSE AND CONTINUOUS NOISE
    CLUFF, GL
    SOUND AND VIBRATION, 1980, 14 (03): : 26 - 28
  • [6] AN INVESTIGATION OF THE EFFECTS OF IMPULSE NOISE EXPOSURE ON MAN - IMPULSE NOISE WITH A RELATIVELY LOW PEAK LEVEL
    YAMAMURA, K
    AOSHIMA, K
    HIRAMATSU, S
    HIKICHI, T
    HIRAMATSU, S
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1980, 43 (02): : 135 - 142
  • [7] AUDIO DOSIMETER - SYSTEM FOR MEASURING PERSONAL NOISE EXPOSURE
    CONN, DO
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1972, 33 (02): : 17 - &
  • [8] Noise monitoring & control: reducing worker exposure to noise
    Envir Technol Atlanta Georgia, 5 (32):
  • [9] AUDIOMETRIC AND ANATOMICAL CORRELATES OF IMPULSE NOISE EXPOSURE
    HENDERSON, D
    HAMERNIK, RP
    SITLER, R
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1974, 99 (01) : 62 - 66
  • [10] COCHLEAR DEGENERATION FOLLOWING IMPULSE NOISE EXPOSURE
    HAMERNIK, RP
    SITLER, RW
    HENDERSO.D
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1972, 52 (01): : 131 - &