Improved office blood pressure control by automatic delayed-reading oscillometric device

被引:0
|
作者
Coll-Brito, V [2 ,3 ,4 ]
Calero, F. [1 ,2 ,3 ,4 ]
Arias, P. [1 ,2 ,3 ]
Ayasreh, N. [1 ,2 ,3 ,4 ]
Ochoa, J. [2 ,3 ,4 ]
Ramos, A. [1 ,2 ,3 ,4 ]
Guirado, Ll [2 ,3 ,4 ]
Fernandez-Llama, P. [1 ,2 ,3 ,4 ]
机构
[1] Unidad HTA & Prevenc Dano Renal, Barcelona, Spain
[2] Fundacao Puigvert, Serv Nefrol, Barcelona, Spain
[3] Univ Autonoma Barcelona, Barcelona, Spain
[4] Inst Invest Biomed St Pau, IIB St Pau, REDinREN, Inst Invest Carlos III, Barcelona, Spain
来源
HIPERTENSION Y RIESGO VASCULAR | 2021年 / 38卷 / 03期
关键词
Clinical blood pressure; Hypertension control; Cardiovascular risk; SEASONAL-VARIATION; HYPERTENSION; HOME; PREVALENCE; DIAGNOSIS;
D O I
10.1016/j.hipert.2021.03.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Office blood pressure (BP) measurement is a recommended procedure, although the out-of-office BP measurements are increasingly used. Objective: To know the degree of BP control by clinical measurement. Material and methods: During November 2019 demographic and clinical data, office attended systolic BP (SBP) and diastolic BP (DBP) measured with an automatic device with delayed reading and, if performed, data from ambulatory BP monitoring (ABPM) were collected. Results: 102 patients (67 men) were included, with a mean age of 64.9 years, 30% diabetic and 34% with cardiovascular complications. 70% had a controlled hypertesion (<140/90 mmHg) by office BP, the mean SBP was 131 +/- 16.5 mmHg and the DBP was 73 +/- 9.5 mmHg. Old age and diabetes were associated with uncontrolled hypertension. Thirty three patients had ABPM data, which allowed them to be classified according to the 24-hour BP into: 30% true normotension, 9% white-coat hypertension, 15% sustained hypertension, and 45% masked hypertension. Conclusion: The use of automatic devices reduces the white-coat phenomenon, improving the % of patients with office BP controlled. However, this is not confirmed outside the clinic, showing the importance of ABPM in the evaluation of hypertension control. Office BP measurement is useful in patients initial assessment and also provides educational aspects, although the methodology must be optimized to define its clinical role. (c) 2021 SEH-LELHA. Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:119 / 124
页数:6
相关论文
共 50 条
  • [41] Repeated office blood pressure measurements with automated device to evaluate blood pressure status.
    Crippa, G
    Sverzellati, E
    Venturi, C
    Antoniotti, P
    JOURNAL OF HYPERTENSION, 2004, 22 : S191 - S191
  • [42] AUTOMATIC OFFICE BLOOD PRESSURE MEASUREMENT WITHOUT DOCTORS OR NURSES PRESENT IS MORE PREDICTIVE OF AMBULATORY BLOOD PRESSURE THAN IS OFFICE BLOOD PRESSURE BY MERCURY SPHYGMOMANOMETER
    Ishikawa, J.
    Nasothimiou, E.
    Karpettas, N.
    Feltheimer, S.
    McDoniel, S.
    Schwartz, J.
    Stergiou, G.
    Pickering, T.
    JOURNAL OF HYPERTENSION, 2009, 27 : S170 - S170
  • [43] Low-cost oscillometric non-invasive blood pressure monitors: device repeatability and device differences
    Sims, AJ
    Reay, CA
    Bousfield, DR
    Menes, JA
    Murray, A
    PHYSIOLOGICAL MEASUREMENT, 2005, 26 (04) : 441 - 445
  • [44] Automatic Calibration of a Device for Blood Pressure Waveform Measurement
    Siemasz, Rafal
    Tomczuk, Krzysztof
    Malecha, Ziemowit
    Felisiak, Piotr Andrzej
    Weiser, Artur
    SENSORS, 2023, 23 (18)
  • [45] Improved Measurement of Blood Pressure by Extraction of Characteristic Features from the Cuff Oscillometric Waveform
    Lim, Pooi Khoon
    Ng, Siew-Cheok
    Jassim, Wissam A.
    Redmond, Stephen J.
    Zilany, Mohammad
    Avolio, Alberto
    Lim, Einly
    Tan, Maw Pin
    Lovell, Nigel H.
    SENSORS, 2015, 15 (06) : 14142 - 14161
  • [46] NORMATIVE OSCILLOMETRIC BLOOD-PRESSURE VALUES IN THE 1ST 5 YEARS IN AN OFFICE SETTING
    PARK, MK
    MENARD, SM
    AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1989, 143 (07): : 860 - 864
  • [47] 30-minute automated, oscillometric blood pressure measurement may become the new standard in measuring blood pressure in the office: a comparative study
    Van der Wel, M.
    Buunk, I.
    van Weel, C.
    Thien, T.
    Bakx, C.
    SWISS MEDICAL WEEKLY, 2009, 139 (33-34) : 32S - 32S
  • [48] Correlation analysis of human upper arm parameters to oscillometric signal in automatic blood pressure measurement
    Bomi Lee
    Jae-Hak Jeong
    Junki Hong
    Yong-Hwa Park
    Scientific Reports, 12
  • [49] Accurate pattern recognition algorithm for automatic oscillometric blood pressure measurement based on physical principles of blood flow
    Pekarski, SE
    JOURNAL OF HYPERTENSION, 2004, 22 : S167 - S167
  • [50] OFFICE BLOOD PRESSURE VARIABILITY: WITHIN SESSION STABILITY ACROSS CONSECUTIVE MEASUREMENTS USING OSCILLOMETRIC DEVICES
    Dekie, Luc
    Connor, Kalvin
    Heilbraun, Jeff
    Rudo, Todd
    JOURNAL OF HYPERTENSION, 2023, 41 : E132 - E133