Improved office blood pressure control by automatic delayed-reading oscillometric device

被引:0
|
作者
Coll-Brito, V [2 ,3 ,4 ]
Calero, F. [1 ,2 ,3 ,4 ]
Arias, P. [1 ,2 ,3 ]
Ayasreh, N. [1 ,2 ,3 ,4 ]
Ochoa, J. [2 ,3 ,4 ]
Ramos, A. [1 ,2 ,3 ,4 ]
Guirado, Ll [2 ,3 ,4 ]
Fernandez-Llama, P. [1 ,2 ,3 ,4 ]
机构
[1] Unidad HTA & Prevenc Dano Renal, Barcelona, Spain
[2] Fundacao Puigvert, Serv Nefrol, Barcelona, Spain
[3] Univ Autonoma Barcelona, Barcelona, Spain
[4] Inst Invest Biomed St Pau, IIB St Pau, REDinREN, Inst Invest Carlos III, Barcelona, Spain
来源
HIPERTENSION Y RIESGO VASCULAR | 2021年 / 38卷 / 03期
关键词
Clinical blood pressure; Hypertension control; Cardiovascular risk; SEASONAL-VARIATION; HYPERTENSION; HOME; PREVALENCE; DIAGNOSIS;
D O I
10.1016/j.hipert.2021.03.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Office blood pressure (BP) measurement is a recommended procedure, although the out-of-office BP measurements are increasingly used. Objective: To know the degree of BP control by clinical measurement. Material and methods: During November 2019 demographic and clinical data, office attended systolic BP (SBP) and diastolic BP (DBP) measured with an automatic device with delayed reading and, if performed, data from ambulatory BP monitoring (ABPM) were collected. Results: 102 patients (67 men) were included, with a mean age of 64.9 years, 30% diabetic and 34% with cardiovascular complications. 70% had a controlled hypertesion (<140/90 mmHg) by office BP, the mean SBP was 131 +/- 16.5 mmHg and the DBP was 73 +/- 9.5 mmHg. Old age and diabetes were associated with uncontrolled hypertension. Thirty three patients had ABPM data, which allowed them to be classified according to the 24-hour BP into: 30% true normotension, 9% white-coat hypertension, 15% sustained hypertension, and 45% masked hypertension. Conclusion: The use of automatic devices reduces the white-coat phenomenon, improving the % of patients with office BP controlled. However, this is not confirmed outside the clinic, showing the importance of ABPM in the evaluation of hypertension control. Office BP measurement is useful in patients initial assessment and also provides educational aspects, although the methodology must be optimized to define its clinical role. (c) 2021 SEH-LELHA. Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:119 / 124
页数:6
相关论文
共 50 条
  • [1] IMPROVED OFFICE BLOOD PRESSURE CONTROL BY AUTOMATIC DELAYED-READING OSCILLOMETRIC DEVICE
    Fernandez-Llama, Patricia
    Coll-Brito, Veronica
    Calero, Francesca
    Arias, Piedad
    Ayasreh, Nadia
    Ochoa, Jackson
    Ramos, Alejandra
    Guirado, Luis
    JOURNAL OF HYPERTENSION, 2022, 40 (SUPPL) : E102 - E102
  • [2] ACCURACY OF AN OSCILLOMETRIC AUTOMATIC BLOOD-PRESSURE DEVICE - THE OMRON-HEM403C
    OBRIEN, E
    ATKINS, N
    JOURNAL OF HUMAN HYPERTENSION, 1995, 9 (09) : 781 - 782
  • [3] ACCURACY OF AN OSCILLOMETRIC AUTOMATIC BLOOD-PRESSURE DEVICE - THE OMRON HEM403C
    WALMA, EP
    VANDOOREN, C
    VANDERDOES, E
    PRINS, A
    MULDER, P
    HOES, AW
    JOURNAL OF HUMAN HYPERTENSION, 1995, 9 (03) : 169 - 174
  • [4] Office blood pressure measurements with oscillometric devices in adolescents: a comparison with home blood pressure
    Jardim, Thiago Veiga
    Gaziano, Thomas A.
    Nascente, Flavia Miquetichuc
    Carneiro, Carolina de Souza
    Morais, Polyana
    Roriz, Vanessa
    Mendonca, Karla Lorena
    Rolim Povoa, Thais Inacio
    Sebba Barroso, Weimar Kunz
    Lima Sousa, Ana Luiza
    Veiga Jardim, Paulo Cesar
    BLOOD PRESSURE, 2017, 26 (05) : 272 - 278
  • [5] Repeated office blood pressure measurement by automated device to evaluate blood pressure control
    Crippa, G
    Sverzellati, E
    Venturi, C
    Antoniotti, P
    AMERICAN JOURNAL OF HYPERTENSION, 2003, 16 (05) : 46A - 46A
  • [6] Estimation of blood pressure control with automatic and ambulatory device
    Silhol, F
    Gassend, R
    Bouchlaghem, K
    Vaisse, B
    Poggi, L
    JOURNAL OF HYPERTENSION, 2001, 19 (08) : A23 - A24
  • [7] Interarm differences in blood pressure should be determined by measuring both arms simultaneously with an automatic oscillometric device
    Lohmann, Friedrich W.
    Eckert, Siegfried
    Verberk, Willem J.
    BLOOD PRESSURE MONITORING, 2011, 16 (01) : 37 - 42
  • [8] EVALUATION OF AN AUTOMATIC OSCILLOMETRIC METHOD OF MEASURING BLOOD-PRESSURE
    FRANCOUAL, M
    HIMMICH, H
    FISCHLER, M
    DAVID, R
    DESSERTENNE, J
    ROHAN, J
    LOIRAT, P
    AGRESSOLOGIE, 1980, 21 : 157 - 161
  • [9] Clinical evaluation of an automated oscillometric blood pressure wrist device
    Cuckson, AC
    Moran, P
    Seed, P
    Reinders, A
    Shennan, AH
    BLOOD PRESSURE MONITORING, 2004, 9 (01) : 31 - 37
  • [10] Home blood pressure measurement with an automatic device (OMRON IC): acceptance and comparison with office blood pressure measurement.
    Gomes, MAM
    Plerin, A
    Alavarce, DC
    Mion, D
    AMERICAN JOURNAL OF HYPERTENSION, 1999, 12 (04) : 165A - 165A