Utility of sonographically guided biopsy in metabolically suspected recurrent lymphoma

被引:4
|
作者
Soudack, Michalle [1 ,4 ]
Bar Shalom, Rachel [2 ,4 ]
Israel, Ora [2 ,4 ]
Ben-Arie, Yehudith [3 ]
Levy, Zofia [4 ]
Gaitini, Diana [1 ,4 ]
机构
[1] Rambam Med Ctr, Dept Med Imaging, Haifa, Israel
[2] Rambam Med Ctr, Dept Nucl Med, Haifa, Israel
[3] Rambam Med Ctr, Dept Pathol, Haifa, Israel
[4] Israel Inst Technol, Ruth Rappaport Fac Med, Haifa, Israel
关键词
computed tomography; interventional sonography; lymphoma; needle biopsy; positron emission tomography; sonography;
D O I
10.7863/jum.2008.27.2.225
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. The purpose of this study was to determine the diagnostic accuracy of sonographically guided biopsy of [F-18]fluorodeoxyglucose (FDG)-avid foci on positron emission tomography (PET)/computed tomography (CT) in patients with lymphoma. Methods. We retrospectively reviewed the medical records of 56 patients with lymphoma (25 male and 31 female; mean age, 48.5 years; range, 22-80 years) who underwent sonographically guided biopsy of hypermetabolic FDG-avid foci precisely localized by PET/CT Biopsies were performed up to 3 months after PET/CT The accuracy of core biopsy was calculated and compared with clinical follow-up and histopathologic results of open biopsy. Results. Sixty-six sonographically guided biopsies were performed in the 56 patients. Histopathologic results were conclusive in 53 (80%) of 66. No complications occurred during or after the procedure. The overall sensitivity, specificity, positive predictive value, and accuracy for diagnosis of lymphoma were 100%, 95%, 97%, and 98%, respectively. Conclusions. Sonographically guided biopsy is a safe and effective means for investigating metabolically active lesions on FDG-PET/CT in patients with known lymphoma.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 50 条
  • [31] Underestimation of Atypical Ductal Hyperplasia at Sonographically Guided Core Biopsy of the Breast
    Jang, Mijung
    Cho, Nariya
    Moon, Woo Kyung
    Park, Jeong Seon
    Seong, Min Hyun
    Park, In Ae
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (05) : 1347 - 1351
  • [32] Comparison of biopsy devices:: Sonographically guided percutaneous liver biopsies in rabbits
    Seçil, M
    Dicle, O
    Göktay, AY
    Yörükoglu, K
    Güre, A
    Pirnar, T
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (05) : 1203 - 1205
  • [33] Sonographically guided core-needle biopsy in the diagnosis of superficial lymphadenopathy
    Cheung, YC
    Wan, YL
    Lui, KW
    Lee, KF
    JOURNAL OF CLINICAL ULTRASOUND, 2000, 28 (06) : 283 - 289
  • [34] SONOGRAPHICALLY GUIDED FINE-NEEDLE ASPIRATION BIOPSY OF ADRENAL MASSES
    MONTALI, G
    SOLBIATI, L
    BOSSI, MC
    DEPRA, L
    DIDONNA, A
    RAVETTO, C
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (05) : 1081 - 1084
  • [35] INTRAMUSCULAR MYXOMA - SONOGRAPHIC APPEARANCE AND SONOGRAPHICALLY GUIDED NEEDLE-BIOPSY
    FORNAGE, BD
    ROMSDAHL, MM
    JOURNAL OF ULTRASOUND IN MEDICINE, 1994, 13 (02) : 91 - 94
  • [36] Sonographically guided core needle biopsy of the breast:: technique, accuracy, and indications
    Buchberger, W
    Niehoff, A
    Obrist, P
    Rettl, G
    Dünser, M
    RADIOLOGE, 2002, 42 (01): : 25 - 32
  • [37] Sonographically guided core biopsy of the salivary gland masses - Safety and efficacy
    Taki, S
    Yamamoto, T
    Kawai, A
    Terahata, S
    Kinuya, K
    Tonami, H
    CLINICAL IMAGING, 2005, 29 (03) : 189 - 194
  • [38] SONOGRAPHICALLY GUIDED PERCUTANEOUS BIOPSY OF SMALL (3 CM OR LESS) MASSES
    READING, CC
    CHARBONEAU, JW
    JAMES, EM
    HURT, MR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (01) : 189 - 192
  • [39] APPLICATION OF SONOGRAPHICALLY GUIDED ASPIRATION BIOPSY IN DIAGNOSING LIVER-TUMORS
    BALTER, SA
    KOSHUG, GD
    RAKU, EP
    KARATA, DI
    VOPROSY ONKOLOGII, 1990, 36 (09) : 1099 - &
  • [40] STEERABLE REAL-TIME SONOGRAPHICALLY GUIDED NEEDLE-BIOPSY
    BUONOCORE, E
    SKIPPER, GJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 136 (02) : 387 - 392