Utility of sonographically guided biopsy in metabolically suspected recurrent lymphoma

被引:4
|
作者
Soudack, Michalle [1 ,4 ]
Bar Shalom, Rachel [2 ,4 ]
Israel, Ora [2 ,4 ]
Ben-Arie, Yehudith [3 ]
Levy, Zofia [4 ]
Gaitini, Diana [1 ,4 ]
机构
[1] Rambam Med Ctr, Dept Med Imaging, Haifa, Israel
[2] Rambam Med Ctr, Dept Nucl Med, Haifa, Israel
[3] Rambam Med Ctr, Dept Pathol, Haifa, Israel
[4] Israel Inst Technol, Ruth Rappaport Fac Med, Haifa, Israel
关键词
computed tomography; interventional sonography; lymphoma; needle biopsy; positron emission tomography; sonography;
D O I
10.7863/jum.2008.27.2.225
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. The purpose of this study was to determine the diagnostic accuracy of sonographically guided biopsy of [F-18]fluorodeoxyglucose (FDG)-avid foci on positron emission tomography (PET)/computed tomography (CT) in patients with lymphoma. Methods. We retrospectively reviewed the medical records of 56 patients with lymphoma (25 male and 31 female; mean age, 48.5 years; range, 22-80 years) who underwent sonographically guided biopsy of hypermetabolic FDG-avid foci precisely localized by PET/CT Biopsies were performed up to 3 months after PET/CT The accuracy of core biopsy was calculated and compared with clinical follow-up and histopathologic results of open biopsy. Results. Sixty-six sonographically guided biopsies were performed in the 56 patients. Histopathologic results were conclusive in 53 (80%) of 66. No complications occurred during or after the procedure. The overall sensitivity, specificity, positive predictive value, and accuracy for diagnosis of lymphoma were 100%, 95%, 97%, and 98%, respectively. Conclusions. Sonographically guided biopsy is a safe and effective means for investigating metabolically active lesions on FDG-PET/CT in patients with known lymphoma.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 50 条
  • [1] Sonographically guided core biopsy
    Oge, T. (tufanoge@yahoo.com), 2023, John Wiley and Sons Ltd (32):
  • [2] Sonographically guided nerve biopsy
    Lolge, SJ
    Morani, AC
    Chaubal, NG
    Khopkar, US
    JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (10) : 1427 - 1430
  • [3] Sonographically guided core biopsy of a parotid mass
    Howlett, David C.
    Menezes, Leon J.
    Lewis, Khari
    Moody, Andrew B.
    Violaris, Nick
    Williams, Michael D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (01) : 223 - 227
  • [4] CT-guided biopsy with abdominal compression in patients with suspected lymphoma
    DeKerviler, E
    Guermazi, A
    Zagdanski, A
    Feger, C
    Panisset, S
    Frija, J
    RADIOLOGY, 1997, 205 : 158 - 158
  • [5] KIDNEY LYMPHOMA - DIAGNOSIS BY SONOGRAPHICALLY GUIDED ASPIRATION
    VERBANCK, J
    SEGAERT, M
    VERHELST, F
    TYTGAT, J
    TANGHE, W
    KIDNEY INTERNATIONAL, 1984, 26 (04) : 529 - 529
  • [6] Sonographically guided soft tissue biopsy with the Bard Magnum biopsy system
    Teichgraeber, U.
    Kluehs, L.
    Benter, T.
    Lausche, A.
    Felix, R.
    Doerken, B.
    Ultrasound in Medicine and Biology, 2000, 26 (SUPPL. 2):
  • [7] Sonographically guided needle biopsy of nonpalpable breast lesions
    Fornage, BD
    JOURNAL OF CLINICAL ULTRASOUND, 1999, 27 (07) : 385 - 398
  • [8] Sonographically guided percutaneous biopsy of gastrointestinal tract lesions
    Marco-Doménech, SF
    Gil-Sánchez, S
    Fernández-García, P
    De la Iglesia-Carreña, P
    Gonzalez-Añón, M
    Arenas-Jimenez, JJ
    Alonso-Charterina, S
    Piqueras-Olmeda, RM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (01) : 147 - 151
  • [10] Needle choice for sonographically guided core biopsy.
    Cardenosa, G
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (03) : 845 - 846