Use of partially covered and uncovered metallic prosthesis for endoscopic ultrasound-guided hepaticogastrostomy: Results of a retrospective monocentric study

被引:52
|
作者
De Cassan, Chiara [1 ,2 ]
Bories, Erwan [1 ]
Pesenti, Christian [1 ]
Caillol, Fabrice [1 ]
Godat, Sebastien [1 ]
Ratone, Jean Philippe [1 ]
Delpero, Jean Robert [1 ]
Ewald, Jacques [1 ]
Giovannini, Marc [1 ]
机构
[1] Inst Paoli Calmettes, Endoscop Unit, Marseille, France
[2] Univ Padua, Div Gastroenterol, Dept Surg Oncol & Gastroenterol, Padua, Italy
关键词
Endoscopic retrograde cholangiopancreatography; hepaticogastrostomy; percutaneous transhepatic biliary drainage; MALIGNANT BILIARY OBSTRUCTION; STENT PLACEMENT; BILE-DUCT; DRAINAGE; MULTICENTER; COMPLICATIONS; EVOLUTION; MIGRATION; BENIGN; ACCESS;
D O I
10.4103/2303-9027.209869
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Objectives: Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) represents an option to treat obstructive jaundice when endoscopic retrograde cholangiopancreatography (ERCP) fails. The success rate of this procedure has been shown to be very high. Up to now, plastic and self-expandable metallic stents (SEMSs) have been employed, each of them presenting some limitations. The aims of this study were to evaluate the technical and functional success rates of EUS-HGS using a dedicated biliary SEMS with a half-covered part (Giobor (R) stent). Methods: We retrospectively reviewed data of patients, who underwent EUS-HGS at our center, with at least 6 months of follow-up. Demographic, clinical, and laboratory data were extracted from the patient's charts and electronic records. Technical success rate was defined as the successful passage of the Giobor stent across the stomach, along with the flow of contrast medium and/or bile through the stent. Functional success rate was considered achieved when the decrease of bilirubin value of at least 25% within the 1st week was obtained. The rate of early and late complications was assessed. Results: A total of 41 patients were included (21F/20M, [ mean age 66, range 45-85]). Technical success rate was obtained in 37 (90.2%) of patients. Functional success rate, analyzable in 29 patients, occurred in 65%. Between the 37 patients in whom HGS was technically feasible, 13 patients (31.7%) presented an early complication, mostly infective. At 6-month follow-up, 10/37 patients (27.0%) required a new biliary drainage (BD) and 11/37 (29.7%) died because of their disease. Conclusions: EUS-HGS using Giobor (R) stent is technically feasible, clinical effective, safe, and may be an alternative to percutaneous transhepatic BD in case of ERCP failure for biliary decompression.
引用
下载
收藏
页码:329 / 335
页数:7
相关论文
共 50 条
  • [21] Endoscopic ultrasound-guided hepaticogastrostomy combined with antegrade stenting using a double bare covered metal stent
    Ogura, Takeshi
    Nishioka, Nobu
    Miyano, Akira
    Kamiyama, Rieko
    Higuchi, Kazuhide
    ENDOSCOPY, 2019, 51 (02) : E24 - E25
  • [22] Bile peritonitis after placement of a metallic stent in endoscopic ultrasound-guided hepaticogastrostomy: A pitfall and the rescue technique
    Ohno, Akihisa
    Fujimori, Nao
    Abe, Toshiya
    Nakamura, Masafumi
    Ogawa, Yoshihiro
    ENDOSCOPY, 2023, 55 : E94 - E95
  • [23] Puncture angle on an endoscopic ultrasound image is independently associated with unsuccessful guidewire manipulation of endoscopic ultrasound-guided hepaticogastrostomy: a retrospective study in Japanese two centers
    Ohno, Akihisa
    Fujimori, Nao
    Kaku, Toyoma
    Matsumoto, Kazuhide
    Murakami, Masatoshi
    Teramatsu, Katsuhito
    Ueda, Keijiro
    Hijioka, Masayuki
    Aso, Akira
    Ogawa, Yoshihiro
    CLINICAL ENDOSCOPY, 2024,
  • [24] Endoscopic ultrasound-guided choledochoduodenostomies with fully covered self-expandable metallic stents
    Tae Jun Song
    Yil Sik Hyun
    Sang Soo Lee
    Do Hyun Park
    Dong Wan Seo
    Sung Koo Lee
    Myung-Hwan Kim
    World Journal of Gastroenterology, 2012, 18 (32) : 4435 - 4440
  • [25] Endoscopic ultrasound-guided choledochoduodenostomies with fully covered self-expandable metallic stents
    Song, Tae Jun
    Hyun, Yil Sik
    Lee, Sang Soo
    Park, Do Hyun
    Seo, Dong Wan
    Lee, Sung Koo
    Kim, Myung-Hwan
    WORLD JOURNAL OF GASTROENTEROLOGY, 2012, 18 (32) : 4435 - 4440
  • [26] A retrospective multicenter study comparing the punctures to B2 and B3 in endoscopic ultrasound-guided hepaticogastrostomy
    Sekine, Masanari
    Hashimoto, Yusuke
    Shibuki, Taro
    Okumura, Kei
    Kobori, Ikuhiro
    Miyagaki, Aki
    Sasaki, Yoshihiro
    Takano, Yuichi
    Matsumoto, Keita
    Mashima, Hirosato
    DEN OPEN, 2023, 3 (01):
  • [27] Efficacy of a Novel Tapered Contrast Catheter for Endoscopic Ultrasound-Guided Hepaticogastrostomy: A Multicenter Study
    Niiya, Fumitaka
    Sato, Tatsunori
    Kaneko, Junichi
    Ishikawa, Kazuma
    Tamai, Naoki
    Yamawaki, Masataka
    Noda, Jun
    Azami, Tetsushi
    Nishimoto, Fumiya
    Takano, Yuichi
    Nagahama, Masatsugu
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (06)
  • [28] Hepatobiliary scintigraphy of bile excretion after endoscopic ultrasound-guided hepaticogastrostomy for malignant biliary obstruction: a retrospective study in Japan
    Yamada, Masanori
    Hara, Kazuo
    Haba, Shin
    Kuwahara, Takamichi
    Okuno, Nozomi
    Kuraishi, Yasuhiro
    Yanaidani, Takafumi
    Ishikawa, Sho
    Yasuda, Tsukasa
    Fukui, Toshitaka
    GASTROINTESTINAL ENDOSCOPY, 2024,
  • [29] Endoscopic ultrasound-guided hepaticogastrostomy using a fully covered metallic stent with self-made multiple side holes for prevention of branch duct occlusion
    Kuraishi, Yasuhiro
    Hara, Kazuo
    Haba, Shin
    DIGESTIVE ENDOSCOPY, 2023, 35 (05) : E78 - E79
  • [30] Successful endoscopic ultrasound-guided hepaticogastrostomy with use of a novel drill dilator for challenging tract dilation
    Ogura, Takeshi
    Uba, Yuki
    Yamamura, Masahiro
    Kawai, Jyunichi
    Nishikawa, Hiroki
    ENDOSCOPY, 2023, 55 : E149 - E150