Imaging of amide proton transfer and nuclear Overhauser enhancement in ischemic stroke with corrections for competing effects

被引:47
|
作者
Li, Hua [1 ,2 ]
Zu, Zhongliang [1 ,3 ]
Zaiss, Moritz [4 ]
Khan, Imad S. [5 ]
Singer, Robert J. [5 ]
Gochberg, Daniel F. [1 ,2 ,3 ]
Bachert, Peter [4 ]
Gore, John C. [1 ,2 ,3 ,6 ,7 ]
Xu, Junzhong [1 ,2 ,3 ]
机构
[1] Vanderbilt Univ, Inst Imaging Sci, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Dept Phys & Astron, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Dept Radiol & Radiol Sci, Nashville, TN 37232 USA
[4] German Canc Res Ctr, DKFZ, Deutsch Krebsforschungszentrum, Dept Med Phys Radiol, Heidelberg, Germany
[5] Geisel Sch Med Dartmouth, Sect Neurosurg, Lebanon, NH USA
[6] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37232 USA
[7] Vanderbilt Univ, Dept Mol Physiol & Biophys, Nashville, TN 37232 USA
基金
美国国家卫生研究院;
关键词
chemical exchange saturation transfer (CEST); amide proton transfer (APT); nuclear Overhauser enhancement (NOE); stroke; ischemia; apparent exchange-dependent relaxation (AREX); MAGNETIZATION-TRANSFER ASYMMETRY; SATURATION-TRANSFER CEST; FOCAL CEREBRAL-ISCHEMIA; CHEMICAL-EXCHANGE; IN-VIVO; TRANSFER CONTRAST; WATER DIFFUSION; ROTATING-FRAME; BRAIN-TISSUE; RELAXATION;
D O I
10.1002/nbm.3243
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Chemical exchange saturation transfer (CEST) potentially provides the ability to detect small solute pools through indirect measurements of attenuated water signals. However, CEST effects may be diluted by various competing effects, such as non-specific magnetization transfer (MT) and asymmetric MT effects, water longitudinal relaxation (T-1) and direct water saturation (radiofrequency spillover). In the current study, CEST images were acquired in rats following ischemic stroke and analyzed by comparing the reciprocals of the CEST signals at three different saturation offsets. This combined approach corrects the above competing effects and provides a more robust signal metric sensitive specifically to the proton exchange rate constant. The corrected amide proton transfer (APT) data show greater differences between the ischemic and contralateral (non-ischemic) hemispheres. By contrast, corrected nuclear Overhauser enhancements (NOEs) around -3.5ppm from water change over time in both hemispheres, indicating whole-brain changes that have not been reported previously. This study may help us to better understand the contrast mechanisms of APT and NOE imaging in ischemic stroke, and may also establish a framework for future stroke measurements using CEST imaging with spillover, MT and T-1 corrections. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:200 / 209
页数:10
相关论文
共 50 条
  • [31] TRANSFER OF CIDNP VIA PROTON-EXCHANGE AND NUCLEAR OVERHAUSER EFFECT
    BARGON, J
    GARDINI, GP
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1979, 101 (26) : 7732 - 7733
  • [32] Quantification of in vivo pH-weighted amide proton transfer (APT) MRI in acute ischemic stroke
    Zhou, Iris Yuewen
    Igarashi, Takahiro
    Guo, Yingkun
    Sun, Phillip Zhe
    MEDICAL IMAGING 2015: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2015, 9417
  • [33] Amide proton transfer MRI at 9.4 T for differentiating tissue acidosis in a rodent model of ischemic stroke
    Jin, Tao
    Wang, Jicheng
    Chung, Julius
    Hitchens, T. Kevin
    Sun, Dandan
    Mettenburg, Joseph
    Wang, Ping
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (05) : 2140 - 2148
  • [34] Amide Proton Transfer MRI Signal as a Surrogate Biomarker of Ischemic Stroke Recovery in Patients With Supportive Treatment
    Yu, Lu
    Chen, Yuhui
    Chen, Min
    Luo, Xiaojie
    Jiang, Shanshan
    Zhang, Yi
    Chen, Haibo
    Gong, Tao
    Zhou, Jinyuan
    Li, Chunmei
    FRONTIERS IN NEUROLOGY, 2019, 10
  • [35] Nuclear Overhauser enhancement (NOE) imaging in the human brain at 7 T
    Jones, Craig K.
    Huang, Alan
    Xu, Jiadi
    Edden, Richard A. E.
    Schaer, Michael
    Hua, Jun
    Oskolkov, Nikita
    Zaca, Domenico
    Zhou, Jinyuan
    McMahon, Michael T.
    Pillai, Jay J.
    van Zijl, Peter C. M.
    NEUROIMAGE, 2013, 77 : 114 - 124
  • [36] Direct saturation-corrected chemical exchange saturation transfer MRI of glioma: Simplified decoupling of amide proton transfer and nuclear overhauser effect contrasts
    Zhou, Iris Yuwen
    Wang, Enfeng
    Cheung, Jerry S.
    Lu, Dongshuang
    Ji, Yang
    Zhang, Xiaoan
    Fulci, Giulia
    Sun, Phillip Zhe
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (06) : 2307 - 2314
  • [37] Imaging human teeth by phosphorus magnetic resonance with nuclear Overhauser enhancement
    Yi Sun
    Ole Brauckmann
    Donald R. Nixdorf
    Arno Kentgens
    Michael Garwood
    Djaudat Idiyatullin
    Arend Heerschap
    Scientific Reports, 6
  • [38] IMINO-PROTON RESONANCES OF YEAST TRANSFER RNAPHE STUDIED BY TWO-DIMENSIONAL NUCLEAR OVERHAUSER ENHANCEMENT SPECTROSCOPY
    HEERSCHAP, A
    MELLEMA, JR
    JANSSEN, HGJM
    WALTERS, JALI
    HAASNOOT, CAG
    HILBERS, CW
    EUROPEAN JOURNAL OF BIOCHEMISTRY, 1985, 149 (03): : 649 - 655
  • [39] Imaging of nuclear Overhauser enhancement in human brain tumour at 3 Tesla
    Shen, Y.
    Xiao, G.
    Shen, Z.
    Cao, Z.
    Zhang, X.
    Tang, X.
    Hu, W.
    Zhang, Z.
    Wu, R.
    EUROPEAN JOURNAL OF NEUROLOGY, 2016, 23 : 845 - 846
  • [40] Imaging human teeth by phosphorus magnetic resonance with nuclear Overhauser enhancement
    Sun, Yi
    Brauckmann, Ole
    Nixdorf, Donald R.
    Kentgens, Arno
    Garwood, Michael
    Idiyatullin, Djaudat
    Heerschap, Arend
    SCIENTIFIC REPORTS, 2016, 6