Anatomic study for ideal and safe posterior C1-C2 transarticular screw fixation

被引:64
|
作者
Jun, BY [1 ]
机构
[1] Inha Univ, Dept Neurosurg, Inchun, South Korea
关键词
atlantoaxial fixation; screw fixation; space available for the screw;
D O I
10.1097/00007632-199808010-00018
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Directions of the C1-C2 posterior transarticular screw trajectories making the longest path or violating the transverse foramen were measured by using an objective measuring method. Objectives. To clarify the directions of the screw trajectory marking the longest paths without violating the transverse foramen. To achieve this, diverse directions of the screw trajectories were objectified by measuring the locations of the points of screw intersection on the superior articular surface of C2. Summary of Background Data. The principal limitation of posterior C1-C2 posterior transarticular screw fixation is the location of the vertebral artery. Because of the lack of an objective measuring method, surgical unsuitability has been decided on the basis of individual experiences as reported in 18% to 23% of cases. Methods. Sagittal reconstructed computed tomographic images were made at 3.5 mm and 6 mm from the spinal canal. C2-C2 transarticular screw trajectories making the longest path or violating the transverse foramen (dangerous trajectory) were drawn, and their points of screw intersection on the superior articular surface of C2 were measured from the posterior rim of the superior articular surface of C2. When the space I: available for the screw behind the points of screw intersection by the dangerous trajectory was equal to or less than 3.5 mm, the case was defined as "unacceptable"; wen the space available for the screw was more than 3.5 mm but equal to or less than 4.5 mm, it was defined as "risky" for the placement of the screw. Results. Trajectories make the longest paths when they pass an average of 3.6 mm and 2.8 mm anterior to the posterior rim of the posterior articular surface of C2 at 3.5-mm lateral images and 6-mm lateral images, respectively. Four of 64 cases were unacceptable or risky unilaterally on 3.5-mm lateral images, and 21 cases were unacceptable or risky on 6-mm lateral images. A sigmoid-shaped increment curve of the risk was noted as the increasing forward inclination of the screw trajectories increased. Conclusions. The areas on the superior articular surface of C2 intersected by the trajectories making the longest paths without violating the transverse foramen are clarified as a guide to the ideal and safe trajectories, The theoretical minimal risk and usual risk of the posterior C1-C2 transarticular screw fixation are presented as well.
引用
收藏
页码:1703 / 1707
页数:5
相关论文
共 50 条
  • [41] Transarticular C1-C2 screw fixation.: Results of unstable odontoid fractures and pseudarthrosis in the elderly
    Kaminski, A.
    Gstrein, A.
    Muhr, G.
    Mueller, E. J.
    UNFALLCHIRURG, 2008, 111 (03): : 167 - 172
  • [42] Computed tomography in the determination of transarticular C1-C2 screw length
    Nadim, Y
    Sabry, F
    Xu, RM
    Ebraheim, N
    ORTHOPEDICS, 2000, 23 (04) : 373 - 375
  • [43] C1-C2 intra-articular screw fixation for atlantoaxial posterior stabilization
    Tokuhashi, Y
    Matsuzaki, H
    Shirasaki, Y
    Tateishi, T
    SPINE, 2000, 25 (03) : 337 - 341
  • [44] Posterior C1-C2 screw-rod fixation and autograft fusion for the treatment of os odontoideum with C1-C2 instability
    Huang, Da-Geng
    Wang, Tao
    Hao, Ding-Jun
    He, Bao-Rong
    Liu, Tuan-Jiang
    Ma, Xiao-Wen
    Yu, Cheng-Cheng
    Feng, Hang
    Zhao, Song-Chum
    Hui, Hua
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2017, 163 : 71 - 75
  • [45] Posterior C1-C2 transarticular screw fixation in the treatment of displaced type II odontoid fractures in the geriatric population - Review of seven cases
    Campanelli, M
    Kattner, KA
    Stroink, A
    Gupta, K
    West, S
    SURGICAL NEUROLOGY, 1999, 51 (06): : 596 - 600
  • [46] Sagittal alignment of the subaxial cervical spine after C1-C2 transarticular screw fixation in rheumatoid arthritis
    Mukai, Yoshihiro
    Hosono, Noboru
    Sakaura, Hironobu
    Fujii, Ryutaro
    Iwasaki, Motoki
    Fuchiya, Tsuyoshi
    Fujiwara, Keiju
    Fuji, Takeshi
    Yoshikawa, Hideki
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (06): : 436 - 441
  • [47] PREOPERATIVE OBLIQUE AXIAL COMPUTED TOMOGRAPHIC IMAGING FOR C1-C2 TRANSARTICULAR SCREW FIXATION - TECHNICAL NOTE
    DULL, ST
    TOSELLI, RM
    NEUROSURGERY, 1995, 37 (01) : 150 - 151
  • [48] Anterior transarticular C1-C2 fixation with contralateral screw insertion: a report of two cases and technical note
    Lvov, Ivan
    Grin, Andrey
    Kaykov, Aleksandr
    Smirnov, Vladimir
    Krylov, Vladimir
    EUROPEAN SPINE JOURNAL, 2018, 27 : S347 - S352
  • [49] Augmentation of occipitocervical contoured rod fixation with C1-C2 transarticular screws
    Yuksel, K. Zafer
    Crawford, Neil R.
    Melton, Stephen
    Dickman, Curtis A.
    SPINE JOURNAL, 2007, 7 (02): : 180 - 187
  • [50] Potential intraoperative factors of screw-related complications following posterior transarticular C1-C2 fixation: a systematic review and meta-analysis
    Lvov, Ivan
    Grin, Andrey
    Talypov, Aleksandr
    Kordonskiy, Anton
    Smirnov, Vladimir
    Grigoriev, Iliya
    Khushnazarov, Ulugbek
    Krylov, Vladimir
    EUROPEAN SPINE JOURNAL, 2019, 28 (02) : 400 - 420