An Analysis of U-Value as a Measure of Variability

被引:9
|
作者
Kong, Xiuyan [1 ]
McEwan, James S. [2 ]
Bizo, Lewis A. [3 ]
Foster, T. Mary [2 ]
机构
[1] Jinan Univ, Affiliated Hosp 1, Dept Rehabil, 2706 A Gaoke Bldg,Tianhe Bei Rd, Guangzhou, Guangdong, Peoples R China
[2] Univ Waikato, Hamilton, New Zealand
[3] Univ New England, Armidale, NSW, Australia
来源
PSYCHOLOGICAL RECORD | 2017年 / 67卷 / 04期
关键词
Behavioral variability; Measure of variability; Stereotypy; U-value; BEHAVIORAL VARIABILITY; OPERANT VARIABILITY; REINFORCEMENT; SEQUENCES; FREQUENCY; RESPONSES; HUMANS;
D O I
10.1007/s40732-017-0219-2
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
The variability in behavior has frequently been assessed using a measure known as the U-value. Of concern in this article were the limits and constraints on U-value as a measure of variability. The relation between the U-value and aspects of variability was examined using three sets of simulated data. Our analysis demonstrates that the U-value as a measure of variability on its own fails to capture repetitive patterns in the sequence of responding. The U-value was shown to reflect the evenness of the distributions of responses across the categories/options used; however, when the number of categories actually used by the participant differed from the total number available, the relation between U-values and the number of categories allocated with responses was shown to be nonlinear. It was also shown that the same value of U can represent different levels of evenness in response distributions over categories, depending on the number of categories/options actually used. These constraints and limitations are discussed in relation to how researchers might report on behavioral variability.
引用
收藏
页码:581 / 586
页数:6
相关论文
共 50 条
  • [41] Evaluation of aerial thermography for measuring the thermal transmittance (U-value) of a building façade
    Rodriguez, Marta Videras
    Melgar, Sergio Gomez
    Marquez, Jose Manuel Andujar
    ENERGY AND BUILDINGS, 2024, 324
  • [42] Simulation Study on the New Average Heat Flux Method to Determine U-Value of a Wall
    曹洁玲
    杨建坤
    于海钢
    刘赟
    邹钺
    JournalofDonghuaUniversity(EnglishEdition), 2021, 38 (04) : 367 - 375
  • [43] Development of affordable hot box calorimeter to determine the U-value of inhomogeneous building material
    Alqahtani, Saad
    Ali, Hafiz Muhammad
    Ali, Hassan
    Farukh, Farukh
    Kandan, Karthikeyan
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2023, 25 : 6492 - 6502
  • [44] Generally valid calculation of the average U-value of double-skin steel walls
    Der allgemein gueltige Waermeschutznachweis doppelschaliger Wandkonstruktionen aus Stahlblech
    1600,
  • [45] Design and evaluation of a detection system for external water condensation on low U-value windows
    Werner, Anna
    Roos, Arne
    Nilsson, Per
    SENSORS AND ACTUATORS A-PHYSICAL, 2007, 138 (01) : 16 - 21
  • [46] Heat and mass transfer for the U-value assessment of opaque walls in the Mediterranean climate: Energy implications
    Bruno, Roberto
    Bevilacqua, Piero
    ENERGY, 2022, 261
  • [47] Thermographic 2D U-value map for quantifying thermal bridges in building facades
    Tejedor, Blanca
    Barreira, Eva
    Almeida, Ricardo M. S. F.
    Casals, Miquel
    ENERGY AND BUILDINGS, 2020, 224
  • [48] Influence of HFM Thermal Contact on the Accuracy of In Situ Measurements of Facades' U-Value in Operational Stage
    Gaspar, Katia
    Casals, Miquel
    Gangolells, Marta
    APPLIED SCIENCES-BASEL, 2021, 11 (03): : 1 - 14
  • [49] U-value assessment by infrared thermography: A comparison of different calculation methods in a Guarded Hot Box
    Nardi, Iole
    Paoletti, Domenica
    Ambrosini, Dario
    de Rubeis, Tullio
    Sfarra, Stefano
    ENERGY AND BUILDINGS, 2016, 122 : 211 - 221
  • [50] A New Metre for Cheap, Quick, Reliable and Simple Thermal Transmittance (U-Value) Measurements in Buildings
    Andujar Marquez, Jose Manuel
    Martinez Bohorquez, Miguel Angel
    Gomez Melgar, Sergio
    SENSORS, 2017, 17 (09):