Changes in Intraocular Pressure and Ocular Biometry After Blepharoplasty

被引:8
|
作者
Ilhan, Cagri [1 ]
Aydemir, Gozde Aksoy [2 ]
Aydemir, Emre [2 ]
机构
[1] Hatay Educ & Res Hosp, Dept Ophthalmol, Ekinci Mah Cevreyolu Cad Royals Pk 13-1 23, Antakya, Hatay, Turkey
[2] Adiyaman Univ Educ & Res Hosp, Dept Ophthalmol, Adiyaman, Turkey
关键词
Blepharoplasty; Dermatochalasis; Intraocular lens power; Intraocular pressure; Ocular biometry; UPPER EYELID BLEPHAROPLASTY; CONTRAST-SENSITIVITY;
D O I
10.1007/s00266-021-02756-9
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose To investigate the effects of blepharoplasty on intraocular pressure (IOP) and ocular biometric parameters. Methods A total of 112 eyelids of 56 patients undergoing bilateral blepharoplasty due to upper eyelid dermatochalasis was included. The patients were classified into three groups according to margin reflex distance (MRD) (Group 1 >4 mm MRD, Group 2 2-4 mm MRD, and Group 3 <2 mm MRD). The IOP and ocular biometric parameters obtained baseline and postoperative 3rd month were compared. Results The demographic characteristics of the groups were similar (p > 0.05, for all). IOP (p = 0.002) and central corneal thickness (p = 0.038) increased in Group 3. The mean amount of the increase in IOP was 0.95mmHg. The keratometric values increased in all groups and corneal astigmatism was also increased in Group 2 and Group 3 (p < 0.001, for all). The mean amount of the increase in corneal astigmatism was 0.54D in Group 3. Anterior chamber depth and axial length did not change (p > 0.05, for all). The intraocular lens powers calculated by six different formulas decreased in Group 3 (p < 0.001, for all), and the mean amount of the decrease was 0.40D. Conclusions Clinicians should be aware of the potential change in IOP and ocular biometric parameters in patients who underwent blepharoplasty. If a patient has glaucoma risk factors, close follow-up is needed after blepharoplasty. Change in strategy or timing may also be needed for dermatochalasis patients when planning corneal refractive surgery or cataract surgery.
引用
收藏
页码:2295 / 2300
页数:6
相关论文
共 50 条
  • [41] Changes in intraocular pressure after topical anaesthetic instillation
    Montero, Javier A.
    Ruiz-Moreno, Jose M.
    Fernandez-Munoz, Marta
    Isabel Rodriguez-Palacios, M.
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2008, 1 (01) : 60 - 62
  • [42] Intraocular pressure changes after treatment for Graves' orbitopathy
    Danesh-Meyer, HV
    Savino, PJ
    Deramo, V
    Sergott, RC
    Smith, AF
    OPHTHALMOLOGY, 2001, 108 (01) : 145 - 150
  • [43] Changes in intraocular pressure after pharmacologic pupil dilation
    Kim, Joon Mo
    Park, Ki Ho
    Han, So Young
    Kim, Kwan Soo
    Kim, Dong Myung
    Kim, Tae Woo
    Caprioli, Joseph
    BMC OPHTHALMOLOGY, 2012, 12
  • [44] INTRAOCULAR-PRESSURE CHANGES AFTER ALKALI BURNS
    PATERSON, CA
    PFISTER, RR
    ARCHIVES OF OPHTHALMOLOGY, 1974, 91 (03) : 211 - 218
  • [45] OCULAR BIOMETRY
    SCHECHTER, RJ
    ARCHIVES OF OPHTHALMOLOGY, 1987, 105 (12) : 1626 - 1627
  • [46] Changes in intraocular pressure after intraocular eye surgery——the influence of measuring technique
    Hrvoje Kovacic
    Roger C.W.Wolfs
    Emine K?l??
    Wishal D.Ramdas
    International Journal of Ophthalmology, 2019, (06) : 967 - 973
  • [47] Intravitreal injection of bevacizumab: changes in intraocular pressure related to ocular axial length
    Cacciamani, Andrea
    Oddone, Francesco
    Parravano, Mariacristina
    Scarinci, Fabio
    Di Nicola, Marta
    Lofoco, Giorgio
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2013, 57 (01) : 63 - 67
  • [48] Intravitreal injection of bevacizumab: changes in intraocular pressure related to ocular axial length
    Andrea Cacciamani
    Francesco Oddone
    Mariacristina Parravano
    Fabio Scarinci
    Marta Di Nicola
    Giorgio Lofoco
    Japanese Journal of Ophthalmology, 2013, 57 : 63 - 67
  • [49] Measurements of ocular properties in response to intraocular pressure changes using an ultrasonic system
    He, Xiaoyin
    Liu, Jun
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 3026 - +
  • [50] Changes of refraction and ocular components induced by decreasing intraocular pressure in vivo.
    Shum, PJT
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 3742 - 3742