摘要
Electrical Impedance Tomography (EIT) is a promising technique in biomedical imaging. Reimaging conductivity distribution within a subject enables the detection of abnormal inclusions within the subject volume. EIT has potential in detection of breast cancer due to variation in impedivity. Using linear difference imaging, variation in impedance within a model can be detected with reference to a base model. The difference approach evaluates the changes in conductivity between two timeframes, allowing the changes and variations be detected. In this paper, investigation of EIT for detection of impurities within a gelatine phantom model is conducted. The ability of a fabricated external sensor belt to detect impurities at various locations are explored along with a voltage distribution graph. Reconstructed images are studied using various image priors and hyperparameter settings to overcome the ill-posed nature of the system. Results showed that the preliminary study of EIT was able to detect difference in EIT images for the breast phantom.
引用
收藏
页码:485 / 490
页数:6
相关论文
共 50 条
  • [41] Monotonicity-Based Regularization for Phantom Experiment Data in Electrical Impedance Tomography
    Harrach, Bastian
    Mach Nguyet Minh
    NEW TRENDS IN PARAMETER IDENTIFICATION FOR MATHEMATICAL MODELS, 2018, : 107 - 120
  • [42] A feasibility study of magnetic resonance driven electrical impedance tomography using a phantom
    Wan, Yuqing
    Negishi, Michiro
    Constable, R. Todd
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (06) : 623 - 644
  • [43] AN Electrical Impedance Tomography System Based On Physical Phantom And It's Preliminary Results
    Tang Mengxing
    Dong Xiuzhen
    Qin Mingxin
    Wang Zhimin
    Shi Xuetao
    You Fusheng(Bio-Medical Engineering Department of theFourth Military Medical University
    Chinese Journal of Biomedical Engineering, 1997, (03) : 125 - 126
  • [44] Evaluation of electrical impedance and computed tomography fusion algorithms using an anthropomorphic phantom
    Chugh, Brige Paul
    Krishnan, Kalpagam
    Liu, Jeff
    Kohli, Kirpal
    MEDICAL PHYSICS, 2014, 41 (08) : 8 - 8
  • [45] A Three-dimensional Phantom for Evaluating the Performance of Electrical Impedance Tomography System
    Li, Wenying
    Zhang, Ke
    Li, Maokun
    Yang, Fan
    Xu, Shenheng
    2022 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE (IMBIOC), 2022, : 257 - 259
  • [46] Development of a digital breast phantom for photoacoustic computed tomography
    Bao, Youwei
    Deng, Handi
    Wang, Xuanhao
    Zuo, Hongzhi
    Ma, Cheng
    BIOMEDICAL OPTICS EXPRESS, 2021, 12 (03) : 1391 - 1406
  • [47] Lung Ventilation Functional Monitoring Based on Electrical Impedance Tomography
    陈晓艳
    王化祥
    赵波
    石小累
    Transactions of Tianjin University, 2009, 15 (01) : 7 - 12
  • [48] Tomography For Electrical Impedance, An Alternative Method For Monitoring Joint Injuries
    Munoz Sanchez, Juan David
    Mosquera Leyton, Victor Hugo
    INGENIERIA SOLIDARIA, 2020, 16 (01):
  • [49] Lung Ventilation Functional Monitoring Based on Electrical Impedance Tomography
    陈晓艳
    王化祥
    赵波
    石小累
    Transactions of Tianjin University, 2009, (01) : 7 - 12
  • [50] Electrical impedance tomography - a method for monitoring regional lung function
    Frerichs, I
    TECHNISCHES MESSEN, 2004, 71 (09): : 519 - 526