Inverse planning anatomy-based dose optimization for HDR-brachytherapy of the prostate using fast simulated annealing algorithm and dedicated objective function

被引:198
|
作者
Lessard, E
Pouliot, J
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
[2] Univ Laval, Ctr Rech Cancerol, Ctr Hosp Univ Quebec, Hotel Dieu Quebec,Serv Radiooncol, Quebec City, PQ G1R 2J6, Canada
关键词
inverse planning; brachytherapy; HDR; prostate; simulated annealing;
D O I
10.1118/1.1368127
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An anatomy-based dose optimization algorithm is developed to automatically and rapidly produce a highly conformal dose coverage of the target volume while minimizing urethra, bladder, and rectal doses in the delivery of an high dose-rate (HDR) brachytherapy boost for the treatment of prostate cancer. The dwell times are optimized using an inverse planning simulated annealing algorithm (IPSA) governed entirely from the anatomy extracted from a CT and by a dedicated objective function (cost function) reflecting clinical prescription and constraints. With this inverse planning approach, the focus is on the physician's prescription and constraint instead of on the technical limitations. Consequently, the physician's control on the treatment is improved. The capacity of this algorithm to represent the physician's prescription is presented for a clinical prostate case. The computation time (CPU) for IPSA optimization is less than 1 min (41 s for 142 915 iterations) for a typical clinical case, allowing fast and practical dose optimization. The achievement of highly conformal dose coverage to the target volume opens the possibility to deliver a higher dose to the prostate without inducing overdosage of urethra and normal tissues surrounding the prostate. Moreover, using the same concept, it will be possible to deliver a boost dose to a delimited tumor volume within the prostate. Finally, this method can be easily extended to other anatomical sites. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:773 / 779
页数:7
相关论文
共 50 条
  • [1] Anatomy-based dose optimization for HDR-brachytherapy of the prostate using fast simulated annealing algorithm
    Lessard, E
    Pouliot, J
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2774 - 2777
  • [2] Anatomy-based inverse planning simulated annealing (IPSA) optimization in HDR prostate brachytherapy
    Jacob, D.
    Raben, A.
    Sarkar, A.
    Grimm, J.
    Simpson, L.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2419 - 2419
  • [3] ANATOMY-BASED INVERSE OPTIMIZATION ALGORITHMS FOR HDR PROSTATE BRACHYTHERAPY
    Lopes, M. D. C.
    Alves de Oliveira, C. C.
    Matos, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S137 - S137
  • [4] A comparison of anatomy-based inverse planning with simulated annealing and graphical optimization for high-dose-rate prostate brachytherapy
    Morton, Gerard C.
    Sankreacha, Raxa
    Halina, Patrick
    Loblaw, Andrew
    [J]. BRACHYTHERAPY, 2008, 7 (01) : 12 - 16
  • [5] Anatomy-based inverse planning dose optimization in HDR prostate implant:: A toxicity study
    Mahmoudieh, A
    Tremblay, C
    Beaulieu, L
    Lachance, B
    Harel, F
    Lessard, É
    Pouliot, J
    Vigneaault, É
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 75 (03) : 318 - 324
  • [6] Multiobjective anatomy-based dose optimization for HDR-brachytherapy with constraint free deterministic algorithms
    Milickovic, N
    Lahanas, M
    Papagiannopoulou, M
    Zamboglou, N
    Baltas, D
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (13): : 2263 - 2280
  • [7] Anatomy-based inverse planning dose optimization for HDR prostate implant boost:: a toxicity report
    Mamouhdieh, A
    Beaulieu, L
    Tremblay, C
    Lachance, B
    Létourneau, A
    Lessard, L
    Pouliot, J
    Vigneault, É
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S104 - S104
  • [8] Anatomy-based inverse planning simulated annealing optimization in high-dose-rate prostate brachytherapy: Significant dosimetric advantage over other optimization techniques
    Jacob, Dayee
    Raben, Adam
    Sarkar, Abhirup
    Grimm, Jimm
    Simpson, Larry
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (03): : 820 - 827
  • [9] Multiobjective inverse planning optimization: Adjustment of dose homogeneity and urethra protection in HDR-brachytherapy of the prostate
    Lessard, E.
    Hsu, I.
    Aubry, J.
    Pouliot, J.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2124 - 2124
  • [10] Anatomy based inverse planning in HDR prostate brachytherapy
    Kolkman-Deurloo, IKK
    Deleye, XGJ
    Jansen, PP
    Koper, PCM
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 (01) : 73 - 77