The Optimization of a Lateral Flow Immunoassay for Detection of Aflatoxin B1 in Potable Water Samples

被引:16
|
作者
Yan, Xiaoxiang [1 ,2 ]
Persaud, Krishna C. [1 ]
机构
[1] Univ Manchester, Sch Chem Engn & Analyt Sci, Manchester M13 9PL, Lancs, England
[2] Univ Glasgow, Glasgow G12 8QQ, Lanark, Scotland
关键词
Aflatoxin B-1; biosensor; lateral flow immunoassay; potable water; IMMUNOCHROMATOGRAPHIC ASSAY; LIQUID; SENSITIVITY;
D O I
10.1109/JSEN.2018.2878449
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Aflatoxin B-1 (AFB(1)) is a highly toxic and carcinogenic metabolite produced by fungi of genus Aspergillus. While AFB(1) contamination in food and crops is well known, little attention has been paid to potable water which is another potential source of AFB(1) contamination that can be ingested by humans. In order to develop a robust, rapidly manufactured sensing device that can monitor the AFB(1) contamination in water, a lateral flow immunostrip based on gold nanoparticles (AuNPs) has been optimized for determination of AFB(1) in potable water samples. A visual detection limit (LOD) of 0.5 ppb was achieved for determination of AFB(1) for the majority of water samples tested. The strip remained functional after being stored at 4 degrees C for 3 months.
引用
收藏
页码:404 / 412
页数:9
相关论文
共 50 条
  • [31] A lateral flow immunochromatographic assay based on nanobody-oriented coupling strategy for aflatoxin B1 detection
    Wang, Xinyang
    Sun, Tieqiang
    Shen, Weili
    Liu, Mingzhu
    Liu, Wentao
    Zuo, Hu
    Zhang, Yiyang
    Geng, Lu
    Wang, Wen
    Shao, Changli
    Bai, Jialei
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 394
  • [32] Enzyme Immunoassay for Measuring Aflatoxin B1 in Legal Cannabis
    Di Nardo, Fabio
    Cavalera, Simone
    Baggiani, Claudio
    Chiarello, Matteo
    Pazzi, Marco
    Anfossi, Laura
    TOXINS, 2020, 12 (04)
  • [33] Fluorometric lateral flow immunoassay for simultaneous determination of three mycotoxins (aflatoxin B1, zearalenone and deoxynivalenol) using quantum dot microbeads
    Li, Runxian
    Meng, Chengzhen
    Wen, Yang
    Fu, Wei
    He, Pingli
    MICROCHIMICA ACTA, 2019, 186 (12)
  • [34] Performance Improvement of the One-Dot Lateral Flow Immunoassay for Aflatoxin B1 by Using a Smartphone-Based Reading System
    Lee, Sangdae
    Kim, Giyoung
    Moon, Jihea
    SENSORS, 2013, 13 (04): : 5109 - 5116
  • [35] Fluorometric lateral flow immunoassay for simultaneous determination of three mycotoxins (aflatoxin B1, zearalenone and deoxynivalenol) using quantum dot microbeads
    Runxian Li
    Chengzhen Meng
    Yang Wen
    Wei Fu
    Pingli He
    Microchimica Acta, 2019, 186
  • [36] Analysis of aflatoxin B1 in human hair samples
    Sabzevari, O.
    Emrarian, I.
    Abdi, K. H.
    Abouhossein, G.
    Amirahmadi, M.
    TOXICOLOGY LETTERS, 2006, 164 : S233 - S233
  • [37] A Gold Nanoparticle and Aflatoxin B1-BSA Conjugates Based Lateral Flow Assay Method for the Analysis of Aflatoxin B1
    Moon, Jihea
    Kim, Giyoung
    Lee, Sangdae
    MATERIALS, 2012, 5 (04): : 634 - 643
  • [38] Multifunctional magnetic bead-based electrochemical immunoassay for the detection of aflatoxin B1 in food
    Tang, Dianping
    Zhong, Zhaoyang
    Niessner, Reinhard
    Knopp, Dietmar
    ANALYST, 2009, 134 (08) : 1554 - 1560
  • [39] Direct Immunoassay for Facile and Sensitive Detection of Small Molecule Aflatoxin B1 based on Nanobody
    Pan, Deng
    Li, Guanghui
    Hu, Huizhen
    Xue, Huaijia
    Zhang, Mingming
    Zhu, Min
    Gong, Xue
    Zhang, Yuanjian
    Wan, Yakun
    Shen, Yanfei
    CHEMISTRY-A EUROPEAN JOURNAL, 2018, 24 (39) : 9869 - 9876
  • [40] Magnetic beads-based multicolor colorimetric immunoassay for ultrasensitive detection of aflatoxin B1
    He, Shan
    Huang, Qitong
    Zhang, Ying
    Zhang, Huifang
    Xu, Huifeng
    Li, Xun
    Ma, Xiaoming
    CHINESE CHEMICAL LETTERS, 2021, 32 (04) : 1462 - 1465