Learning based non-rigid multi-modal image registration using Kullback-Leibler divergence

被引:0
|
作者
Guetter, C [1 ]
Xu, CY
Sauer, FA
Hornegger, J
机构
[1] Siemens Corp Res, Imaging & Visualizat Dept, Princeton, NJ USA
[2] Univ Erlangen Nurnberg, Inst Comp Sci, Erlangen, Germany
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The need for non-rigid multi-modal registration is becoming increasingly common for many clinical applications. To date, however, existing proposed techniques remain as largely academic research effort with very few methods being validated for clinical product use. It has been suggested by Crum et al. [1] that the context-free nature of these methods is one of the main limitations and that moving towards context-specific methods by incorporating prior knowledge of the underlying registration problem is necessary to achieve registration results that are accurate and robust enough for clinical applications. In this paper, we propose a novel non-rigid multi-modal registration method using a variational formulation that incorporates a prior learned joint intensity distribution. The registration is achieved by simultaneously minimizing the Kullback-Leibler divergence between an observed and a learned joint intensity distribution and maximizing the mutual information between reference and alignment images. We have applied our proposed method on both synthetic and real images with encouraging results.
引用
收藏
页码:255 / 262
页数:8
相关论文
共 50 条
  • [21] Validation of a non-rigid registration algorithm for multi-modal data
    Rogelj, P
    Kovacic, S
    Gee, JC
    [J]. MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 299 - 307
  • [22] The Spiking Cortical Model Based Structural Representations for Non-Rigid Multi-Modal Medical Image Registration
    Zhu, Fei
    Ren, Jinxia
    Ding, Mingyue
    Zhang, Xuming
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (05) : 1001 - 1004
  • [23] MULTI-MODAL NON-RIGID IMAGE REGISTRATION BASED ON SIMILARITY AND DISSIMILARITY WITH THE PRIOR JOINT INTENSITY DISTRIBUTIONS
    So, Ronald W. K.
    Chung, Albert C. S.
    [J]. 2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 368 - 371
  • [24] Edge Detection Method of Binary Image Based on Kullback-Leibler Divergence
    Li, Jianjun
    Wei, Zhihui
    Zhang, Zhengjun
    [J]. PROCEEDINGS OF 2008 INTERNATIONAL PRE-OLYMPIC CONGRESS ON COMPUTER SCIENCE, VOL II: INFORMATION SCIENCE AND ENGINEERING, 2008, : 466 - 468
  • [25] Learning-Based Multi-Modal Rigid Image Registration By Using Bhattacharyya Distances
    So, Ronald W. K.
    Chung, Albert C. S.
    [J]. 2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2642 - 2645
  • [26] Tomographic Image Reconstruction Based on Minimization of Symmetrized Kullback-Leibler Divergence
    Kasai, Ryosuke
    Yamaguchi, Yusaku
    Kojima, Takeshi
    Yoshinaga, Tetsuya
    [J]. MATHEMATICAL PROBLEMS IN ENGINEERING, 2018, 2018
  • [27] Infrared-visible remote sensing image registration method based on Kullback-Leibler divergence using variational approximation
    Wang, Jia
    Wu, Hao
    Fu, Ruigang
    Kong, Lingshuang
    Zuo, Yi
    [J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2024, 32 (20): : 3071 - 3084
  • [28] A Novel Multiple Kernel Learning Method Based on the Kullback-Leibler Divergence
    Liang, Zhizheng
    Zhang, Lei
    Liu, Jin
    [J]. NEURAL PROCESSING LETTERS, 2015, 42 (03) : 745 - 762
  • [29] Kullback-Leibler distance optimization for non-rigid registration of echo-planar to structural magnetic resonance brain images
    Gholipour, Ali
    Kehtamavaz, Nasser
    Briggs, Richard W.
    Gopinath, Kaundinya S.
    [J]. 2007 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-7, 2007, : 3017 - +
  • [30] Point similarity measures for non-rigid registration of multi-modal data
    Rogelj, P
    Kovacic, S
    Gee, JC
    [J]. COMPUTER VISION AND IMAGE UNDERSTANDING, 2003, 92 (01) : 112 - 140