Trochanteric Gamma nail and compression hip screw for trochanteric fractures -: A randomized, prospective, comparative study in 210 elderly patients with a new design of the Gamma nail

被引:187
|
作者
Utrilla, AL [1 ]
Reig, JS [1 ]
Muñoz, FM [1 ]
Tufanisco, CB [1 ]
机构
[1] Hosp Gen Elda, Dept Orthopaed Surg, Alicante 03600, Spain
关键词
trochanteric femoral fractures; Gamma nail; intramedullary nail; compression hip screw;
D O I
10.1097/01.bot.0000151819.95075.ad
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To compare the results between a new intrainedullary Gamma nail and a compression hip screw in the treatment of trochanteric fractures. Design: Prospective randomized. Setting: Level I trauma center. Patients: Two hundred ten consecutive patients older than 65 years with trochanteric femoral fractures. Interventions: Treatment with a compression hip screw or a new design of the Trochanteric Gamma nail (180 nun in length with a mediolateral angle of 4 degrees and available only with a proximal diameter of 17 mm and distal diameter of 11 mm). Main Outcome Measurements: Operative and fluoroscopy times, blood loss, functional outcome, complication rate, and failure of fixation. Results: The Trochanteric Gamma nail was used in 104 patients and the compression hip screw in 106. The 2 groups were similar in tenus of their preoperative data, with a median follow-up of 13.6 months (range 12-30). The results show no difference in operating time (P = 0.21), but the Trochanteric Gamma nail group had a significantly shorter fluoroscopy time (P = 0.006), and the number of patients transfused and the mean of units of blood transfused were significantly less in the Trochanteric Gamma nail group (P = 0.013, 0.046, respectively). Mortality within 12 months was similar in both groups (P = 0.83). All fractures were radiographically healed at the last visit. There was no difference in intraoperative and postoperative complications or rate of fixation failure between the 2 groups, and no case of secondary shaft fracture of the femur was encountered in this study. In the entire series, there was no difference in the functional outcome (P = 0.74), but the postoperative walking ability was better in those patients with unstable fractures who were treated with the Trochanteric Gamma naiL (P = 0.0 17). Conclusions: The new Trochanteric Gamma nail is an effective method for the treatment of trochanteric femoral fractures in elderly patients. The indication for either Trochanteric Gamma nail or compression hip screw is similar in stable fractures, but we recommend the use of the Trochanteric Gamma nail for unstable trochanteric fractures.
引用
收藏
页码:229 / 233
页数:5
相关论文
共 50 条
  • [31] Fixation of intertrochanteric hip fractures: Gamma nail versus dynamic hip screw. A randomized, prospective study
    OBrien, PJ
    Meek, RN
    Blachut, PA
    Broekhuyse, HM
    Sabharwal, S
    [J]. CANADIAN JOURNAL OF SURGERY, 1995, 38 (06) : 516 - 520
  • [32] InterTan nail versus Gamma3 nail for intramedullary nailing of unstable trochanteric fractures
    Dankai Wu
    Guangkai Ren
    Chuangang Peng
    Xuanlin Zheng
    Fengmin Mao
    Yueyang Zhang
    [J]. Diagnostic Pathology, 9
  • [33] InterTan nail versus Gamma3 nail for intramedullary nailing of unstable trochanteric fractures
    Wu, Dankai
    Ren, Guangkai
    Peng, Chuangang
    Zheng, Xuanlin
    Mao, Fengmin
    Zhang, Yueyang
    [J]. DIAGNOSTIC PATHOLOGY, 2014, 9
  • [34] The classic nail in the therapy of trochanteric fractures A prospective, controlled study
    T. Fritz
    C. Weiß
    C. Krieglstein
    A. Quentmeier
    [J]. Archives of Orthopaedic and Trauma Surgery, 1999, 119 : 308 - 314
  • [35] Failure of Fixation in Trochanteric Hip Fractures: Does Nail Design Matter?
    Davidson, Amit
    Giannoudis, Peter V.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (10S) : S26 - S32
  • [36] The trochanteric gamma nail versus the dynamic hip screw:: a prospective randomised study.: One-year follow-up of 146 intertrochanteric fractures
    Ovesen, O.
    Andersen, M.
    Poulsen, T.
    Nymark, T.
    Overgaard, S.
    Rock, N. D.
    [J]. HIP INTERNATIONAL, 2006, 16 (04) : 293 - 298
  • [37] The classic nail in the therapy of trochanteric fractures - A prospective, controlled study
    Fritz, T
    Weiss, C
    Krieglstein, C
    Quentmeier, A
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1999, 119 (5-6) : 308 - 314
  • [38] THE GAMMA-NAIL IN THE TREATMENT OF TROCHANTERIC FRACTURES - INDICATIONS AND RESULTS, A STUDY OF 121 CASES
    KEMPF, I
    GROSSE, A
    TAGLANG, G
    FAVREUL, E
    [J]. REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1993, 79 (01): : 29 - 40
  • [39] A PROSPECTIVE RANDOMIZED COMPARISON OF THE DYNAMIC HIP SCREW AND THE GAMMA LOCKING NAIL
    RADFORD, PJ
    NEEDOFF, M
    WEBB, JK
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (05): : 789 - 793
  • [40] The trochanteric nail versus the sliding hip screw for intertrochanteric hip fractures: A review of 93 cases
    Crawford, CH
    Malkani, AL
    Cordray, S
    Roberts, CS
    Sligar, W
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (02): : 325 - 328