Lightning Impulse Breakdown Voltage of Rice Bran Oil for Transformer Application

被引:1
|
作者
Hamid, Mardhiah Hayati Abdul [1 ]
Ishak, Mohd Taufiq [1 ]
Suhaimi, Nur Sabrina [1 ]
Adnan, Jaafar [1 ]
Makmor, Nazrul Fariq [1 ]
Katim, Nurul Izzatul Akma [2 ]
Abd Rahman, Rahisham [3 ]
机构
[1] Natl Def Univ Malaysia, Fac Engn, Dept Elect & Elect Engn, Kuala Lumpur 57000, Malaysia
[2] Malaysian Allied Hlth Sci Acad MAHSA Univ, Fac Engn & Built Environm, Jenjarom 42610, Selangor, Malaysia
[3] Univ Tun Hussein Onn Malaysia, Fac Elect & Elect Engn, Batu Pahat 86400, Johor, Malaysia
关键词
rice bran oi; transformer liquid insulation; vegetable oils; lightning impulse breakdown voltage; power transformer and dielectric material; NATURAL ESTER; PALM OIL; INSULATING LIQUID; NONUNIFORM FIELD; COCONUT OIL; PROPAGATION;
D O I
10.3390/en14165084
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Transformer oil does not only serve as an insulating liquid, but also in removing heat from the windings and cores. Mineral oil (MO) has been widely used in transformers for more than 150 years. Recently, researchers have attempted to search for alternative insulating oils due to the possibility that MO will run out in the future together with the concern on fire safety and environmental pollution. Among the potential oils is rice bran oil (RBO). This work presents the studies of the lightning impulse (LI) of RBO behavior under various electric fields, gap distances and testing methods. The electrical performances of LI tests show that RBO and Palm Oil (PO) have lower LI breakdown voltage than MO under both uniform and non-uniform electric fields. However, the difference in LI breakdown voltages between RBO, PO and MO are slightly small which is less than 20%. In addition, there is no significant effect in the various testing methods under both uniform field and non-uniform field where the percentages of difference are less than 12% and 8% respectively. The data of LI breakdown voltage were statistically analysed to predict the withstand voltage and 50% breakdown voltage of oil samples by using Weibull distribution. The Weibull distribution of MO, PO and RBO has well fit with the fitting line. Finally, the relationship between LI voltages under a non-uniform field with various parameters of PO and RBO was obtained and proposed. From this work, it can be concluded that RBO shows promising results to be considered as an alternative to MO in transformer applications.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Application of data fusion in transformer oil breakdown voltage measuring instrument
    Li, Lan-Jun
    Yu, Shou-Yi
    Tang, Yao-Geng
    Gao, Song
    Gaodianya Jishu/High Voltage Engineering, 2008, 34 (06): : 1267 - 1270
  • [22] Electrical properties of palm oil and rice bran oil under AC stress for transformer application
    Hamid, M. H. A.
    Ishak, M. T.
    Suhaimi, N. S.
    Adnan, J.
    Hashim, N., I
    Ariffin, M.
    Katim, N. I. A.
    Abd Rahman, Rahisham
    ALEXANDRIA ENGINEERING JOURNAL, 2022, 61 (11) : 9095 - 9105
  • [23] Characteristics of negative lightning impulse breakdown voltage in pure water
    Takamura N.
    Araoka N.
    Kamohara S.
    Hino Y.
    Beppu T.
    Hanai M.
    Takamura, Norimitsu (takamura@fukuoka-u.ac.jp), 2018, Institute of Electrical Engineers of Japan (138) : 441 - 448
  • [24] Prediction of Lightning Impulse Voltage Induced Breakdown in Vacuum Interrupters
    Marconato, N.
    De Lorenzi, A.
    Pilan, N.
    Bettini, P.
    Specogna, R.
    Lawall, A.
    Wenzel, N.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (06) : 3367 - 3373
  • [25] Stochastic Character Modelling of Breakdown under Lightning Impulse Voltage
    Guerlek, Akif
    Malekian, Kaveh
    Schufft, Wolfgang
    2016 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2016, : 346 - 351
  • [26] Prediction of Lightning Impulse Voltage Induced Breakdown in Vacuum Interrupters
    Marconato, N.
    De Lorenzi, A.
    Pilan, N.
    Bettini, P.
    Lawall, A.
    Wenzel, N.
    PROCEEDINGS OF THE 27TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV), VOL 1, 2016, : 41 - 44
  • [27] Basic considerations concerning lightning impulse voltage breakdown in vacuum
    Schümann, U
    Kurrat, M
    ISDEIV: XXITH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, VOLS 1 AND 2, PROCEEDINGS, 2004, 21 : 84 - 87
  • [28] Streamer Characteristic and Breakdown in Synthetic and Natural Ester Transformer Liquids with Pressboard Interface under Lightning Impulse Voltage
    Liu, Q.
    Wang, Z. D.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (06) : 1908 - 1917
  • [29] Effect of lightning impulse voltage to the pd activity and breakdown voltage of liquid insulation
    Suwarno
    Aulia
    2014 INTERNATIONAL CONFERENCE ON POWER ENGINEERING AND RENEWABLE ENERGY (ICPERE), 2014, : 171 - 174
  • [30] FORMATION AND CHARACTER OF THE IMPULSE BREAKDOWN IN TRANSFORMER OIL.
    Ignacz, P.
    1600, IEEE, New York, NY