Fast Spin-Echo Triple Echo Dixon: Initial Clinical Experience With a Novel Pulse Sequence for Simultaneous Fat-Suppressed and Nonfat-Suppressed T2-Weighted Spine Magnetic Resonance Imaging

被引:32
|
作者
Low, Russell N. [1 ,2 ]
Austin, Matthew J. [3 ]
Ma, Jingfei [4 ]
机构
[1] Sharp & Childrens MRI Ctr, San Diego, CA 92123 USA
[2] San Diego Imaging Med Grp, San Diego, CA 92123 USA
[3] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
关键词
MR imaging; 2-point Dixon; fat suppression; INVERSION-RECOVERY; PHASE-CORRECTION; WATER; EFFICIENT; SEPARATION; IDEAL; MRI; DECOMPOSITION; PROTON;
D O I
10.1002/jmri.22453
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate a prototype fast spin-echo (FSE) triple-echo Dixon (FTED) technique for T2-weighted spine imaging with and without fat suppression compared to conventional T2-weighted fast recovery (FR) FSE and short-tau inversion recovery (STIR) imaging. Materials and Methods: Sixty-one patients were referred for spine magnetic resonance imaging (MRI) including sagittal FTED (time 2:26), STIR (time 2:42), and T2 FRFSE (time 2:55). Two observers compared STIR and VIED water images and T2 FRFSE and FTED T2 images for overall image quality, fat suppression, anatomic sharpness, motion, cerebrospinal fluid (CSF) flow artifact, susceptibility, and disease depiction. Results: On FTED images water and fat separation was perfect in 58 (.95) patients. Compared to STIR, the FTED water images demonstrated less motion in 57 (.93) of 61 patients (P < 0.05), better anatomic sharpness in 51 (.84) and patients (P < 0.05), and less CSF flow artifact in 7 (.11) P < 0.05) patients. There was no difference in fat suppression or chemical shift artifact. T2 FRFSE and FTED T2 images showed equivalent motion, CSF flow, and chemical shift artifact. Lesion depiction was equivalent on FTED water and STIR images and FTED T2 and T2 FRFSE images. Conclusion: FTED efficiently provides both fat-suppressed and nonfat-suppressed T2-weighted spine images with excellent image quality, equal disease depiction, and 56% reduction in scan time compared to conventional STIR and T2 FRFSE.
引用
收藏
页码:390 / 400
页数:11
相关论文
共 50 条
  • [31] Can inversion-recovery gradient- and spin-echo T2-weighted MR imaging be an alternative to fast spin-echo imaging with fat suppression?
    Kanematsu, M
    Hoshi, H
    RADIOLOGY, 1999, 212 (01) : 291 - 291
  • [32] MR MYELOGRAPHY USING HEAVILY T2-WEIGHTED FAST SPIN-ECHO PULSE SEQUENCES WITH FAT PRESATURATION
    KRUDY, AG
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (06) : 1315 - 1320
  • [33] MR Imaging of the Spine at 3.0T with T2-Weighted IDEAL Fast Recovery Fast Spin-Echo Technique
    Ren, Ai-Jun
    Guo, Yong
    Tian, Shu-Ping
    Shi, Li-Jing
    Huang, Min-Hua
    KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (01) : 44 - 52
  • [34] T2-weighted spin-echo MR imaging of the liver: Breath-hold fast spin-echo versus non-breath-hold fast spin-echo images with and without fat suppression
    Soyer, P
    LeNormand, S
    deGivry, SC
    Gueye, C
    Somveille, E
    Scherrer, A
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (03) : 593 - 597
  • [35] ARE SAGITTAL T2-WEIGHTED FAST SPIN-ECHO MR-IMAGES SUFFICIENT FOR ROUTINE SPINE IMAGING
    MIAUX, Y
    FELDMAN, L
    DUCERVEAU, MN
    MARTINDUVERNEUIL, N
    COGNARD, C
    SAVIN, D
    CHIRAS, J
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1995, 16 (07) : 1558 - 1559
  • [36] MULTISLAB 3-DIMENSIONAL T2-WEIGHTED FAST SPIN-ECHO IMAGING OF THE HIPPOCAMPUS - SEQUENCE OPTIMIZATION
    MURAKAMI, JW
    WEINBERGER, E
    TSURUDA, JS
    MITCHELL, JD
    YUAN, C
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 309 - 315
  • [37] Three-Dimensional Fast Spin-Echo Imaging without Fat Suppression of the Knee: Diagnostic Accuracy Comparison to Fat-Suppressed Imaging on 1.5T MRI
    Cho, Hee Woo
    Suh, Jin-Suck
    Park, Jin-Oh
    Kim, Hyoung-Sik
    Chung, Soo Yoon
    Lee, Young Han
    Hahn, Seok
    YONSEI MEDICAL JOURNAL, 2017, 58 (06) : 1186 - 1194
  • [38] MR dynamic Gadolinium-enhanced fast multiplanar spoiled gradient-echo and spin-echo T1-weighted fat-suppressed techniques in diagnosis of pancreatic carcinoma
    Meng-Su Zeng
    Fu-Hua Yan
    Kang-Rong Zhou
    Zhu-Wan Chen
    Ji-Zhang Sun
    Cai-Zhong Chen
    Wei-Bing Shi From the Dapartment of Radiology
    Hepatobiliary & Pancreatic Diseases International, 2002, (02) : 294 - 298
  • [39] Findings of fat-suppressed T2-weighted and diffusion-weighted magnetic resonance imaging in the diagnosis of non-palpable testes
    Kato, Toshiki
    Kojima, Yoshiyuki
    Kamisawa, Hideyuki
    Takeuchi, Mitsuru
    Mizuno, Kentaro
    Sasaki, Shigeru
    Kohri, Kenjiro
    Hayashi, Yutaro
    BJU INTERNATIONAL, 2011, 107 (02) : 290 - 294