Preliminary Study on the Kidney Elasticity Quantification in Patients With Chronic Kidney Disease Using Virtual Touch Tissue Quantification

被引:6
|
作者
Zheng, Xiao Zhi [1 ,2 ]
Yang, Bin [1 ]
Fu, Ning Hua [1 ]
机构
[1] Nanjing Univ, Sch Med, Jinling Hosp, Dept Ultrasound, Nanjing 210008, Jiangsu, Peoples R China
[2] Fourth Affiliated Hosp Nantong, Dept Ultrasound, Yancheng, Peoples R China
关键词
Ultrasonography; Virtual Touch Tissue Quantitative; Chronic Kidney Disease; DIAGNOSIS;
D O I
10.5812/iranjradiol.12026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Virtual touch tissue quantification (VTTQ) provides numerical measurements (shear wave velocity (SWV) values) of tissue stiffness. Objectives: The purpose of this study was to describe the SWV values of the kidney by VTTQ and to examine the clinical usefulness of this procedure in the evaluation of elasticity changes in the kidneys of patients with chronic kidney disease (CKD). Patients and Methods: Sixty-five patients with CKD and seventy healthy participants were included in this study. A total of 270 kidneys were examined by VTTQ. The kidney elasticity was expressed as shear wave velocity. The SWV values, blood serum creatinine (Scr)/BUN and pathological findings were analyzed and compared between patients with CKD and healthy participants. Results: In patients with CKD and healthy participants, the SWV values both gradually decreased from the renal cortex to the medulla and renal sinus The SWV value of the renal cortex in patients with CKD was less than that of healthy participants (P < 0.05), and the SWV value of the renal cortex in patients with renal insufficiency was significantly less than in those with normal renal function (2.46 +/- 0.15 vs. 3.45 +/- 0.26 m/s, P < 0.05). The best cutoff value for predicting renal insufficiency (Scr > 1.24 mg/dL or/and BUN > 21 mg/DL) was a SWV value of the renal cortex of less than 1.92 m/s with a sensitivity of 84.4% (95% CI: 67.2-94.7%) and a specificity of 96.8% (95% CI: 83.3-99.9%) (P < 0.001). Conclusion: VTTQ can sensitively detect the elasticity changes in patients with CKD, and it can effectively predict renal insufficiency. This technology provides a valuable tool for the assessment of CKD.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Diagnostic Accuracy of Virtual Touch Quantification and Virtual Touch Imaging Quantification Sonoelastography Techniques in Pediatric Undescended Testes Patients
    Ozkan, Mehmet Burak
    Bilgic, Meltem
    Bicakci, Unal
    Germiyanoglu, Cankon
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2019, 35 (02) : 96 - 103
  • [32] ROLE OF VIRTUAL TOUCH TISSUE QUANTIFICATION IN HASHIMOTO'S THYROIDITIS
    Lin, Zi-mei
    Wang, Yao
    Liu, Chun-mei
    Yan, Cao-xin
    Huang, Pin-tong
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (06): : 1164 - 1169
  • [33] Virtual Touch Tissue Imaging and Quantification in the Evaluation of Thyroid Nodules
    Zhou, Hang
    Zhou, Xian-Li
    Xu, Hui-Xiong
    Li, Dan-Dan
    Liu, Bo-Ji
    Zhang, Yi-Feng
    Xu, Jun-Mei
    Bo, Xiao-Wan
    Li, Xiao-Long
    Guo, Le-Hang
    Qu, Shen
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (02) : 251 - 260
  • [34] VTTQ (VIRTUAL TOUCH TISSUE QUANTIFICATION) FOR EVALUATION OF LIVER TUMORS
    Iijima, Hiroko
    Tanaka, Hironori
    Yoshida, Masahiro
    Iwai, Takashi
    Takashima, Tomoyuki
    Sakai, Yoshiyuki
    Aizawa, Nobuhiro
    Iwata, Kazunari
    Ikeda, Naoto
    Iwata, Yoshinori
    Enomoto, Hirayuki
    Saito, Masaki
    Imanishi, Hiroyasu
    Iimuro, Yuji
    Fujimoto, Jiro
    Nishiguchi, Shuhei
    HEPATOLOGY, 2011, 54 : 909A - 909A
  • [35] A Preliminary Investigation of Depression and Kidney Functioning in Patients with Chronic Kidney Disease
    Cukor, Daniel
    Fruchter, Yvette
    Halen, Nisha Ver
    Naidoo, Shivana
    Patel, Ankita
    Saggi, Subodh J.
    NEPHRON CLINICAL PRACTICE, 2012, 122 (3-4): : 139 - 145
  • [36] Quantification of the burden of chronic kidney disease in Latin America: an invisible epidemic
    Rosas-Valdez, Fernando Ulises
    Aguirre-Vazquez, Andrea Fernanda
    Agudelo-Botero, Marcela
    REVISTA PANAMERICANA DE SALUD PUBLICA-PAN AMERICAN JOURNAL OF PUBLIC HEALTH, 2024, 48
  • [37] Tissue elasticity estimated by acoustic radiation force impulse quantification depends on the applied transducer force: an experimental study in kidney transplant patients
    Syversveen, Trygve
    Midtvedt, Karsten
    Berstad, Audun E.
    Brabrand, Knut
    Strom, Erik H.
    Abildgaard, Andreas
    EUROPEAN RADIOLOGY, 2012, 22 (10) : 2130 - 2137
  • [38] Tissue elasticity estimated by acoustic radiation force impulse quantification depends on the applied transducer force: an experimental study in kidney transplant patients
    Trygve Syversveen
    Karsten Midtvedt
    Audun E. Berstad
    Knut Brabrand
    Erik H. Strøm
    Andreas Abildgaard
    European Radiology, 2012, 22 : 2130 - 2137
  • [39] ARFI-based tissue elasticity quantification and kidney graft dysfunction: First clinical experiences
    Stock, K. F.
    Klein, B. S.
    Cong, M. T. Vo
    Regenbogen, C.
    Kemmner, S.
    Buettner, M.
    Wagenpfeil, S.
    Matevossian, E.
    Renders, L.
    Heemann, U.
    Kuechle, C.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2011, 49 (1-4) : 527 - 535
  • [40] Evaluation of penile erection rigidity in healthy men using virtual touch tissue quantification
    Zheng, Xiaozhi
    Ji, Ping
    Mao, Hongwei
    Wu, Jing
    RADIOLOGY AND ONCOLOGY, 2012, 46 (02) : 114 - 118