Evaluation of residual hearing in cochlear implants candidates using auditory steady-state response

被引:4
|
作者
Ramos, Henrique Faria [1 ]
Grasel, Signe Schuster [1 ]
de Oliveira Beck, Roberto Miquelino [1 ]
Takahashi-Ramos, Marystella Tomoe [1 ]
Ramos, Bernardo Faria [1 ]
de Almeida, Edigar Resende [1 ]
Bento, Ricardo Ferreira [1 ]
Neto, Rubens de Brito [1 ]
机构
[1] Univ Sao Paulo, Sch Med, Dept Otolaryngol, Sao Paulo, Brazil
关键词
Auditory evoked potentials; auditory thresholds; sensorineural hearing loss; residual hearing; cochlear implantation; BRAIN-STEM RESPONSE; STIMULATION; THRESHOLDS; CHILDREN; IMPAIRMENT; ADULTS;
D O I
10.3109/00016489.2014.971463
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Conclusion: The correlations between behavioral and auditory steady-state response (ASSR) thresholds were significant at 500, 1000, 2000, and 4000 Hz. ASSR presented high sensitivity and specificity in the detection of residual hearing in cochlear implant candidates when compared with warble-tone audiometry. Objectives: To assess residual hearing in cochlear implant candidates by comparing the electrophysiological thresholds obtained in dichotic single-frequency ASSR with behavioral thresholds at 500, 1000, 2000, and 4000 Hz. Methods: This was a comparative study between ASSR and warble-tone audiometry thresholds in 40 cochlear implant candidates (80 ears) before cochlear implantation with bilateral severe-to-profound sensorineural hearing loss. Results: Thresholds were obtained in 62.5% of all frequencies evaluated in warble-tone audiometry and in 63.1% in the ASSR. ASSR sensitivity was 96% and specificity was 91.6%. Mean differences between behavioral and ASSR thresholds did not reach significance at any frequencies. Strong correlations between behavioral and ASSR thresholds were observed in 500, 1000, and 2000 Hz and moderate in 4000 Hz, with correlation coefficients varying from 0.65 to 0.81. On 90% of occasions, ASSR thresholds were acquired within 10 dB of behavioral thresholds.
引用
下载
收藏
页码:246 / 253
页数:8
相关论文
共 50 条
  • [41] Auditory Steady-State Response and Hearing Impairment in Survivors of Childhood Bacterial Meningitis in Luanda, Angola
    Karppinen, Mariia
    Rugemalira, Emilie
    Savonius, Okko
    Cruzeiro, Manuel Leite
    Aarnisalo, Antti
    Jutila, Topi
    Pelkonen, Tuula
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (08)
  • [42] Auditory Steady-State Response Thresholds in Adults With Conductive and Mild to Moderate Sensorineural Hearing Loss
    Hosseinabadi, Reza
    Jafarzadeh, Sadegh
    IRANIAN RED CRESCENT MEDICAL JOURNAL, 2015, 17 (01) : 1 - 7
  • [43] Cochlear implants for children with significant residual hearing
    Dettman, S
    D'Costa, WA
    Dowell, RC
    Winton, EJ
    Hill, KL
    Williams, SS
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2004, 130 (05) : 612 - 618
  • [44] SURGICAL EVALUATION OF CANDIDATES FOR COCHLEAR IMPLANTS
    BLACK, FO
    LILLY, DJ
    FOWLER, LP
    STYPULKOWSKI, PH
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1987, 96 (01): : 96 - 99
  • [45] The auditory steady-state response for objective audiometry in infants
    Swanepoel, DeWet
    SALUD I CIENCIA, 2007, 15 (05): : 868 - 872
  • [46] The auditory steady-state response is not a suitable monitor of anesthesia
    Pockett, S
    Tan, SM
    ANESTHESIA AND ANALGESIA, 2002, 95 (05): : 1318 - 1323
  • [47] Thresholds determined using the monotic and dichotic multiple auditory steady-state response technique in normal-hearing subjects
    Herdman, AT
    Stapells, DR
    SCANDINAVIAN AUDIOLOGY, 2001, 30 (01): : 41 - 49
  • [48] Sensitivity and specificity of auditory steady-state response testing
    Rabelo, Camila Maia
    Schochat, Eliane
    CLINICS, 2011, 66 (01) : 87 - 93
  • [49] Imaging the dynamics of the auditory steady-state evoked response
    Simpson, MIG
    Hadjipapas, A
    Barnes, GR
    Furlong, PL
    Witton, C
    NEUROSCIENCE LETTERS, 2005, 385 (03) : 195 - 197
  • [50] A Procedural Framework for Auditory Steady-State Response Detection
    Van Dun, Bram
    Rombouts, Geert
    Wouters, Jan
    Moonen, Marc
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (04) : 1098 - 1107