Spatially varying scatter compensation for digital chest radiography

被引:0
|
作者
Baydush, AH [1 ]
Floyd, CE [1 ]
机构
[1] Duke Univ, Med Ctr, Durham, NC 27710 USA
关键词
Bayesian; statistics; digital; chest radiography; image processing;
D O I
10.1117/12.310971
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Previously, we have shown the effectiveness of using Bayesian image estimation (BIE) to reduce scatter and increase the contrast to noise ratio (CNR) in digital chest radiography without degradation of resolution. Here, we investigate the incorporation of a spatially varying scatter model. Previously, BIE used a simple model for scatter, where scatter was modeled as a spatially invariant radial exponential with a single full-width at half-maximum and magnitude. This invariance resulted in some overcompensation and some undercompensation. A new spatially varying scatter model, where each pixel can have a different scatter kernel magnitude, was incorporated into BIE and used to reduce scatter in quantitative chest radiographs. Scatter fractions were reduced to less than 3% in the lung and mediastinum at 8 iterations. The original BIE technique only reduced scatter fractions to less the 2% in the lung and 38% in the mediastinum. CNR was improved by approximately 60% in the lung region and 200% in the mediastinum. No degradation of resolution was measured. Visual inspection showed improvement of image quality. Incorporation of a spatially varying scatter model into BIE reduces scatter to levels which far exceed those provided by an anti-scatter grid and can increase CNR without loss of resolution.
引用
下载
收藏
页码:930 / 937
页数:8
相关论文
共 50 条
  • [11] Digital radiography of the chest
    Freedman, MT
    Artz, DS
    SEMINARS IN ROENTGENOLOGY, 1997, 32 (01) : 38 - 44
  • [12] Digital chest radiography
    Schaefer-Prokop, C
    JOURNAL OF THORACIC IMAGING, 2003, 18 (03) : 123 - 123
  • [13] DIGITAL RADIOGRAPHY OF THE CHEST
    OESTMANN, JW
    GREENE, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1989, 150 (04): : 465 - 471
  • [14] DIGITAL CHEST RADIOGRAPHY
    BOGREN, HG
    EUROPEAN JOURNAL OF RADIOLOGY, 1983, 3 (03) : 231 - 233
  • [15] DIGITAL CHEST RADIOGRAPHY
    HANSELL, DM
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 1993, 49 (02): : 117 - 120
  • [16] GENERALIZED DUAL-ENERGY-WINDOW SCATTER COMPENSATION IN SPATIALLY VARYING MEDIA FOR SPECT
    SMITH, MF
    JASZCZAK, RJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03): : 531 - 546
  • [17] DIGITAL RADIOGRAPHY OF THE CHEST
    FRASER, RG
    JOURNAL OF THE CANADIAN ASSOCIATION OF RADIOLOGISTS-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1983, 34 (04): : 340 - 340
  • [18] THE SIGNIFICANCE OF EFFICIENT SCATTER REMOVAL IN CHEST RADIOGRAPHY
    HERRERA, M
    MOORE, R
    JUSTICH, E
    CASTANEDAZUNIGA, WR
    AMPLATZ, K
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1982, 137 (06): : 711 - 717
  • [19] BAYESIAN IMAGE ESTIMATION OF DIGITAL CHEST RADIOGRAPHY - INTERDEPENDENCE OF NOISE, RESOLUTION, AND SCATTER FRACTION
    BAYDUSH, AH
    FLOYD, CE
    MEDICAL PHYSICS, 1995, 22 (08) : 1255 - 1261
  • [20] Optimizing Contrast Resolution in Digital Chest Radiography by Varying Copper Filtration and kVp
    Balac, Vesna
    Grossman, Robert
    Griswold, Randy
    Bowman, Dennis
    RADIOLOGIC TECHNOLOGY, 2023, 95 (02) : 94 - 104