Spatially varying scatter compensation for digital chest radiography

被引:0
|
作者
Baydush, AH [1 ]
Floyd, CE [1 ]
机构
[1] Duke Univ, Med Ctr, Durham, NC 27710 USA
关键词
Bayesian; statistics; digital; chest radiography; image processing;
D O I
10.1117/12.310971
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Previously, we have shown the effectiveness of using Bayesian image estimation (BIE) to reduce scatter and increase the contrast to noise ratio (CNR) in digital chest radiography without degradation of resolution. Here, we investigate the incorporation of a spatially varying scatter model. Previously, BIE used a simple model for scatter, where scatter was modeled as a spatially invariant radial exponential with a single full-width at half-maximum and magnitude. This invariance resulted in some overcompensation and some undercompensation. A new spatially varying scatter model, where each pixel can have a different scatter kernel magnitude, was incorporated into BIE and used to reduce scatter in quantitative chest radiographs. Scatter fractions were reduced to less than 3% in the lung and mediastinum at 8 iterations. The original BIE technique only reduced scatter fractions to less the 2% in the lung and 38% in the mediastinum. CNR was improved by approximately 60% in the lung region and 200% in the mediastinum. No degradation of resolution was measured. Visual inspection showed improvement of image quality. Incorporation of a spatially varying scatter model into BIE reduces scatter to levels which far exceed those provided by an anti-scatter grid and can increase CNR without loss of resolution.
引用
收藏
页码:930 / 937
页数:8
相关论文
共 50 条
  • [1] SCATTER COMPENSATION IN DIGITAL CHEST RADIOGRAPHY USING FOURIER DECONVOLUTION
    FLOYD, CE
    BEATTY, PT
    RAVIN, CE
    [J]. INVESTIGATIVE RADIOLOGY, 1989, 24 (01) : 30 - 33
  • [2] SPATIALLY VARYING SCATTER ESTIMATION IN PORTABLE CHEST RADIOGRAPHY WITH AN ARTIFICIAL NEURAL NETWORK
    LO, JY
    FLOYD, CE
    BOWSHER, JE
    RAVIN, CE
    [J]. RADIOLOGY, 1992, 185 : 300 - 300
  • [3] SCATTER COMPENSATION IN DIGITAL CHEST RADIOGRAPHY USING THE POSTERIOR BEAM STOP TECHNIQUE
    LO, JY
    FLOYD, CE
    BAKER, JA
    RAVIN, CE
    [J]. MEDICAL PHYSICS, 1994, 21 (03) : 435 - 443
  • [4] SCATTER COMPENSATION FOR DIGITAL CHEST RADIOGRAPHY USING MAXIMUM-LIKELIHOOD EXPECTATION MAXIMIZATION
    FLOYD, CE
    BAYDUSH, AH
    LO, JY
    BOWSHER, JE
    RAVIN, CE
    [J]. INVESTIGATIVE RADIOLOGY, 1993, 28 (05) : 427 - 433
  • [5] VARIABLE COMPENSATION TECHNIQUE FOR DIGITAL RADIOGRAPHY OF THE CHEST
    DOBBINS, JT
    POWELL, AO
    [J]. RADIOLOGY, 1989, 173 (02) : 451 - 458
  • [6] Digital selenium radiography: anti-scatter grid for chest radiography in a clinical study
    Bernhardt, TM
    Rapp-Bernhardt, U
    Hausmann, T
    Reichel, G
    Krause, UW
    Doehring, W
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (873): : 963 - 968
  • [7] SCATTER REDUCTION IN PORTABLE DIGITAL CHEST RADIOGRAPHY WITH BAYESIAN IMAGE ESTIMATION
    BAYDUSH, AH
    FLOYD, CE
    LO, JY
    BOWSHER, JE
    RAVIN, CE
    [J]. RADIOLOGY, 1992, 185 : 305 - 305
  • [8] THE REDUCTION OF SCATTER FOG IN CHEST RADIOGRAPHY
    ARDRAN, GM
    CROOKS, HE
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1964, 37 (438): : 477 - 479
  • [9] DIGITAL CHEST RADIOGRAPHY
    STANLEY, RJ
    [J]. ALABAMA JOURNAL OF MEDICAL SCIENCES, 1985, 22 (02): : 154 - 156
  • [10] DIGITAL CHEST RADIOGRAPHY
    MACMAHON, H
    DOI, K
    [J]. CLINICS IN CHEST MEDICINE, 1991, 12 (01) : 19 - 32