Lesion-preserving unpaired image-to-image translation between MRI and CT from ischemic stroke patients

被引:3
|
作者
Gutierrez, Alejandro [1 ]
Tuladhar, Anup
Rajashekar, Deepthi
Forkert, Nils D.
机构
[1] Univ Calgary, Dept Radiol, Calgary, AB, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Modality translation; Stroke; Attention; CycleGAN; RECANALIZATION; OCCLUSION; FLAIR;
D O I
10.1117/12.2613203
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Depending on the application, multiple imaging modalities are available for diagnosis in the clinical routine. As a result of this, repositories of patient scans often contain mixed modalities. This poses a challenge for image analysis methods, which require special modifications to work with multiple modalities. This is especially critical for deep learning-based methods, which require large amounts of data. Within this context, a typical example is follow-up imaging in acute ischemic stroke patients, which is an important step in determining potential complications from the evolution of a lesion. In this study, we addressed the mixed modalities issue by translating unpaired images between two of the most relevant follow-up stroke modalities, namely non-contrast computed tomography (NCCT) and fluid-attenuated inversion recovery (FLAIR) MRI. For the translation, we use the widely used cycle-consistent generative adversarial network (CycleGAN). To preserve stroke lesions after translation, we implemented and tested two modifications to regularize them: (1) we use manual segmentations of the stroke lesions as an attention channel when training the discriminator networks, and (2) we use an additional gradient-consistency loss to preserve the structural morphology. For the evaluation of the proposed method, 238 NCCT and 244 FLAIR scans from acute ischemic stroke patients were available. Our method showed a considerable improvement over the original CycleGAN. More precisely, it is capable to translate images between NCCT and FLAIR while preserving the stroke lesion's shape, location, and modality-specific intensity (average Kullback-Leibler divergence improved from 2,365 to 396). Our proposed method has the potential of increasing the amount of available data used for existing and future applications while conserving original patient features and ground truth labels.
引用
收藏
页数:7
相关论文
共 35 条
  • [21] The impact of image fusion in resolving discrepant findings between FDG-PET and MRI/CT in patients with gynaecological cancers
    Cheng-Chien Tsai
    Chien-Sheng Tsai
    Koon-Kwan Ng
    Chyong-Huey Lai
    Swei Hsueh
    Pan-Fu Kao
    Ting-Chang Chang
    Ji-Hong Hong
    Tzu-Chen Yen
    European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 1674 - 1683
  • [22] The impact of image fusion in resolving discrepant findings between FDG-PET and MRI/CT in patients with gynaecological cancers
    Tsai, CC
    Tsai, CS
    Ng, KK
    Lai, CH
    Hsueh, S
    Kao, PF
    Chang, TC
    Hong, JH
    Yen, TC
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (12) : 1674 - 1683
  • [23] The results of image fusion in identifying discrepant findings between FDG-PET and MRI/CT in gynecologic cancer patients.
    Tsai, CC
    Tsai, CS
    Ng, KK
    Lai, CH
    Hsueh, S
    Kao, PF
    Yen, TC
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 401P - 401P
  • [24] Medical image analysis methods in MR/CT-imaged acute-subacute ischemic stroke lesion: Segmentation, prediction and insights into dynamic evolution simulation models. A critical appraisal
    Rekik, Islem
    Allassonniere, Stephanie
    Carpenter, Trevor K.
    Wardlaw, Joanna M.
    NEUROIMAGE-CLINICAL, 2012, 1 (01) : 164 - 178
  • [25] Quantitative Analysis of Leukoaraiosis Burden in 2363 Consecutive Acute Ischemic Stroke Patients: A Report from the Korea's Nationwide Image-based Stroke Database Project
    Kim, D-E
    Woo, S-H
    Jang, M-U
    Jeong, S-W
    Park, J-M
    Cha, J-K
    Lee, S. J.
    Lee, B-C
    Yu, K-H
    Cho, K-S
    Hong, K-S
    Lee, K-B
    Park, K-J
    Choi, H-K
    Bae, H-J
    CEREBROVASCULAR DISEASES, 2013, 35 : 242 - 242
  • [26] Comparison of image quality and quantification between Philips Ingenuity TF PET/MRI and Gemini TF PET/CT data in prostate cancer patients
    Oprea-Lager, D. E.
    Yaqub, M.
    Jongsma, F.
    Pieters-van den Bos, I.
    Reinhard, R.
    Hoekstra, O. S.
    Lammertsma, A. A.
    Boellaard, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S411 - S412
  • [27] Predictive value of CT angiography source image ASPECTS in patients with anterior circulation acute ischemic stroke after endovascular treatment: ultimate infarct size and clinical outcome
    Park, Jung-Soo
    Lee, Jong Myong
    Kwak, Hyo-Sung
    Chung, Gyoung Ho
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (04) : 342 - 346
  • [28] Discrepancy between lesion distributions on methionine PET and MR images in patients with glioblastoma multiforme: insight from a PET and MR fusion image study
    Miwa, K
    Shinoda, J
    Yano, H
    Okumura, A
    Iwama, T
    Nakashima, T
    Sakai, N
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2004, 75 (10): : 1457 - 1462
  • [29] Comparison of multiphase data from CT perfusion vs clinical 4-phase CT scans with respect to image quality, lesion detection, and LI-RADS classification in HCC patients
    Mohammadi, A.
    Bartholmae, W.
    Woisetschlager, M.
    HELIYON, 2022, 8 (01)
  • [30] Medical image analysis methods in MR/CT-imaged acute-subacute ischemic stroke lesion: Segmentation, prediction and insights into dynamic evolution simulation models. A critical appraisal (vol 1, pg 164, 2012)
    Rekik, Islem
    Allassonniere, Stephanie
    Carpenter, Trevor K.
    Wardlaw, Joanna M.
    NEUROIMAGE-CLINICAL, 2013, 2 : 600 - 600