The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique

被引:74
|
作者
Kwon, Heejin [1 ]
Cho, Jinhan [1 ]
Oh, Jongyeong [1 ]
Kim, Dongwon [1 ]
Cho, Junghyun [1 ]
Kim, Sanghyun [1 ]
Lee, Sangyun [1 ]
Lee, Jihyun [1 ]
机构
[1] Dong A Univ Hosp, Dept Radiol, Busan, South Korea
来源
BRITISH JOURNAL OF RADIOLOGY | 2015年 / 88卷 / 1054期
关键词
FILTERED BACK-PROJECTION; COMPUTED-TOMOGRAPHY; IMAGE-QUALITY; CHEST CT; EXPOSURE;
D O I
10.1259/bjr.20150463
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To investigate whether reduced radiation dose abdominal CT images reconstructed with adaptive statistical iterative reconstruction V (ASIR-V) compromise the depiction of clinically competent features when compared with the currently used routine radiation dose CT images reconstructed with ASIR. Methods: 27 consecutive patients (mean body mass index: 23.55 kg m(-2) underwent CT of the abdomen at two time points. At the first time point, abdominal CT was scanned at 21.45 noise index levels of automatic current modulation at 120 kV. Images were reconstructed with 40% ASIR, the routine protocol of Dong-A University Hospital. At the second time point, follow-up scans were performed at 30 noise index levels. Images were reconstructed with filtered back projection (FBP), 40% ASIR, 30% ASIR-V, 50% ASIR-V and 70% ASIR-V for the reduced radiation dose. Both quantitative and qualitative analyses of image quality were conducted. The CT dose index was also recorded. Results: At the follow-up study, the mean dose reduction relative to the currently used common radiation dose was 35.37% (range: 19-49%). The overall subjective image quality and diagnostic acceptability of the 50% ASIR-V scores at the reduced radiation dose were nearly identical to those recorded when using the initial routine-dose CT with 40% ASIR. Subjective ratings of the qualitative analysis revealed that of all reduced radiation dose CT series reconstructed, 30% ASIR-V and 50% ASIR-V were associated with higher image quality with lower noise and artefacts as well as good sharpness when compared with 40% ASIR and FBP. However, the sharpness score at 70% ASIR-V was considered to be worse than that at 40% ASIR. Objective image noise for 50% ASIR-V was 34.24% and 46.34% which was lower than 40% ASIR and FBP. Conclusion: Abdominal CT images reconstructed with ASIR-V facilitate radiation dose reductions of to 35% when compared with the ASIR. Advances in knowledge: This study represents the first clinical research experiment to use ASIR-V, the newest version of iterative reconstruction. Use of the ASIR-V algorithm decreased image noise and increased image quality when compared with the ASIR and FBP methods. These results suggest that high-quality low-dose CT may represent a new clinical option.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction
    Ichikawa, Yasutaka
    Kitagawa, Kakuya
    Nagasawa, Naoki
    Murashima, Shuichi
    Sakuma, Hajime
    BMC MEDICAL IMAGING, 2013, 13
  • [42] CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction
    Yasutaka Ichikawa
    Kakuya Kitagawa
    Naoki Nagasawa
    Shuichi Murashima
    Hajime Sakuma
    BMC Medical Imaging, 13
  • [43] Low-tube-voltage combined with adaptive statistical iterative reconstruction-V technique in CT venography of lower limb deep vein thrombosis
    Dan Chen
    Jiahui Zhou
    Peixi Wang
    Quanxu Ge
    Min Xu
    Wei Qiu
    Xinnan Li
    Xiaodong Wang
    Scientific Reports, 8
  • [44] Low-tube-voltage combined with adaptive statistical iterative reconstruction-V technique in CT venography of lower limb deep vein thrombosis
    Chen, Dan
    Zhou, Jiahui
    Wang, Peixi
    Ge, Quanxu
    Xu, Min
    Qiu, Wei
    Li, Xinnan
    Wang, Xiaodong
    SCIENTIFIC REPORTS, 2018, 8
  • [45] Reduced Radiation Dose with Model-based Iterative Reconstruction versus Standard Dose with Adaptive Statistical Iterative Reconstruction in Abdominal CT for Diagnosis of Acute Renal Colic
    Fontarensky, Mikael
    Alfidja, Agaicha
    Perignon, Renan
    Schoenig, Arnaud
    Perrier, Christophe
    Mulliez, Aurelien
    Guy, Laurent
    Boyer, Louis
    RADIOLOGY, 2015, 276 (01) : 156 - 166
  • [46] Radiation dose reduction in CT with adaptive statistical iterative reconstruction (ASIR) for patients with bronchial carcinoma and intrapulmonary metastases
    Schaefer, M. -L.
    Luedemann, L.
    Boening, G.
    Kahn, J.
    Fuchs, S.
    Hamm, B.
    Streitparth, F.
    CLINICAL RADIOLOGY, 2016, 71 (05) : 442 - 449
  • [47] Estimated Radiation Dose Reduction Using Adaptive Statistical Iterative Reconstruction in Coronary CT Angiography: The ERASIR Study
    Leipsic, Jonathon
    LaBounty, Troy M.
    Heilbron, Brett
    Min, James K.
    Mancini, G. B. John
    Lin, Fay Y.
    Taylor, Carolyn
    Dunning, Allison
    Earls, James P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 655 - 660
  • [48] Influence of deep learning image reconstruction and adaptive statistical iterative reconstruction-V on coronary artery calcium quantification
    Wang, Yiran
    Zhan, Hefeng
    Hou, Jiameng
    Ma, Xueyan
    Wu, Wenjie
    Liu, Jie
    Gao, Jianbo
    Guo, Ying
    Zhang, Yonggao
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (23)
  • [49] Characterization of adaptive statistical iterative reconstruction algorithm for dose reduction in CT: A pediatric oncology perspective
    Brady, S. L.
    Yee, B. S.
    Kaufman, R. A.
    MEDICAL PHYSICS, 2012, 39 (09) : 5520 - 5531
  • [50] Reducing Radiation Dose and Improving Image Quality in CT Portal Venography Using 80 kV and Adaptive Statistical Iterative Reconstruction-V in Slender Patients
    Ren, Zhanli
    Zhang, Xirong
    Hu, Zhijun
    Li, Dou
    Liu, Zhentang
    Wei, Donghong
    Jia, Yongjun
    Yu, Nan
    Yu, Yong
    Lei, Yuxin
    Chen, Xiaoxia
    Guo, Changyi
    Ren, Zhanliang
    He, Taiping