Monitoring and Evaluation of the Anomalous Vibration of a Cable in a Stayed Bridge

被引:0
|
作者
Alvarado Cardenas, Roberto [1 ,2 ]
Carrion Viramontes, Francisco Javier [1 ,3 ]
Lopez Lopez, J. Alfredo [3 ]
Toledano Andrade, Juan Carlos [3 ]
机构
[1] Univ Autonoma Queretaro, Cerro Campanas S-N, Queretaro 76000, Qro, Mexico
[2] Tecnol Monterrey Campus Queretaro, Queretaro 76130, Qro, Mexico
[3] Inst Mexicano Transporte, Sanfandila, Queretaro, Mexico
关键词
Vibration analysis; Cable stayed bridges; Structural health monitoring; SUSPENSION BRIDGE;
D O I
10.1117/12.815630
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
After an extensive analysis, the Rio Papaloapan Bridge in the state of Veracruz, Mexico, was scheduled for maintenance to replace the upper anchorage element of 20 cables that were identified as structurally deficient. For this rehabilitation, an extensive monitoring was implemented to ensure the integrity of the bridge. As a result, abnormal vibration levels were detected in one cable (cable 9 in semi-harp 1), particularly for winds over 50 km/h. To determine the origin of this behavior, additional vibration measurements were implemented to evaluate the dynamic vibrations of the different elements involved. Comparison of the frequency spectrum of different cables with same characteristics and tensions, it was found that the abnormal cable had high vibration levels within the range of 10 to 20 Hz. At the same time, the frequency spectrum for their corresponding upper anchorage of the cable also showed significant differences for the same range of frequencies and higher levels were detected for the same atypical cable in the semi-harp plane (xy plane). Analysis from the vibration data concluded that the tension of the cable was within specifications and the abnormal behavior was not due to distension. Simulation studies confirmed that reduction in the structural stiffness for the anchorage element induced high vibration levels in the range within 20 Hz and the dynamic coupling with the higher vibration modes of the cable was the most probable cause for the extensive vibration in the cable. Also, simulation analysis showed that a damping system could minimize significantly the vibration levels between 8 and 25 Hz. The foregoing gave us the opportunity to conclude that the cable # 9 o semi-harp 1, is under an abnormal conditions due to a dynamic vibration coupling to its upper anchorage element and the higher vibration in the xy plane in this anchorage element was most probably to stiffness reduction. Based on the previous, monitoring and detailed inspection of the anchorage element was recommended, and at the same time, consideration of a damping system is highly recommended to reduce vibration damage.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Ambient vibration testing on a large span cable-stayed bridge
    Zong, ZH
    Ren, WX
    Peng, XL
    8th International Conference on Inspection Appraisal Repairs & Maintenance of Structures, 2003, : 179 - 186
  • [42] AMBIENT VIBRATION TESTING AND STRUCTURAL IDENTIFICATION OF A CABLE-STAYED BRIDGE
    Alaggio, Rocco
    Bedon, Chiara
    Benedettini, Francesco
    Dilena, Michele
    Morassi, Antonino
    6TH IOMAC: INTERNATIONAL OPERATIONAL MODAL ANALYSIS CONFERENCE PROCEEDINGS, 2015, : 57 - 66
  • [43] Cable-stayed bridge vibration due to road surface roughness
    Wang, Ton-Lo
    Huang, Dongzhou
    Journal of structural engineering New York, N.Y., 1992, 118 (05): : 1354 - 1374
  • [44] Ambient vibration testing and structural identification of a cable-stayed bridge
    Bedon, Chiara
    Dilena, Michele
    Morassi, Antonino
    MECCANICA, 2016, 51 (11) : 2777 - 2796
  • [45] Dynamic Monitoring of a Cable-Stayed Bridge: Monitoring System and First Results
    Pereira, Sergio
    Magalhaes, Filipe
    Caetano, Elsa
    Cunha, Alvaro
    Toullier, Thibaud
    Dumoulin, Jean
    EUROPEAN WORKSHOP ON STRUCTURAL HEALTH MONITORING (EWSHM 2022), VOL 2, 2023, : 33 - 41
  • [46] Cable Health Monitoring System for Long-span Cable-stayed Bridge
    Gao Chao
    Li Xinke
    Guo Yongcai
    He Fuliang
    DISASTER ADVANCES, 2011, 4 : 130 - 135
  • [47] Cable-beam related vibration of a long span railway cable-stayed bridge
    Wang T.
    Liu D.
    Huang H.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2019, 38 (17): : 103 - 114
  • [48] Identification of cable vibration frequency for cable-stayed bridge based on edge line tracking
    Xue, Hao
    Peng, Zhenrui
    Yin, Hong
    Zhendong yu Chongji/Journal of Vibration and Shock, 2024, 43 (19): : 153 - 162
  • [49] Assessment of environmental effects in scour monitoring of a cable-stayed bridge simply based on pier vibration measurements
    Wu, Wen-Hwa
    Chen, Chien-Chou
    Shi, Wei-Sheng
    Huang, Chun-Ming
    SMART STRUCTURES AND SYSTEMS, 2017, 20 (02) : 231 - 246
  • [50] Cable-beam vibration characteristics of cable-stayed bridge under external excitations
    Wang, Tao
    Shen, Ruili
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2015, 50 (06): : 1001 - 1010