Ligand-exchange detection of phosphorylated peptides using liquid chromatography electrospray mass spectrometry

被引:8
|
作者
Krabbe, JG [1 ]
Lingeman, H [1 ]
Niessen, WMA [1 ]
Irth, H [1 ]
机构
[1] Vrije Univ Amsterdam, Fac Sci, Div Chem, Dept Analyt Chem & Appl Spect, NL-1081 HV Amsterdam, Netherlands
关键词
D O I
10.1021/ac0349476
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrospray ionization mass spectrometry (ESI-MS) is used to selectively detect analytes with a high affinity for metal ions. The detection method is based on the selective monitoring of a competing ligand at its specific m/z value that is released during the ligand-exchange reaction of a metal-ligand complex with analyte(s) eluting from a reversed-phase liquid chromatography column. The ligand-exchange reaction proceeds in a postcolumn reaction detection system placed prior to the inlet of the electrospray MS interface. The feasibility of metal affinity detection by ESI-MS is demonstrated using phosphorylated peptides and iron(III)methylcalcein blue as reactant, as a model system. Methylcalcein blue (MCB) released upon interaction with phosphorylated peptides is detected at m/z 278. The ligand-exchange detection is coupled to a C8 reversed-phase column to separate several nonphosphorylated enkephalins and the phosphorylated peptides pp60 c-src (P) and M2170. Detection limits of 2 muM were obtained for pp60 c-src (P) and M2170. The linearity of the detection method is tested in the range of 2-80 mumol/L phosphorylated compounds (r(2) = 0.9996), and a relative standard deviation of less than 8% (n = 3) for all MCB responses of the different concentrations of phosphorylated compounds was obtained. The presented method showed specificity for phosphorylated peptides and may prove a useful tool for studying other ligand-exchange reactions and metal-protein interactions.
引用
收藏
页码:6853 / 6860
页数:8
相关论文
共 50 条
  • [11] LIGAND-EXCHANGE CHROMATOGRAPHY OF RACEMATES - INFLUENCE OF TEMPERATURE AND CONCENTRATION OF ELUENT ON LIGAND-EXCHANGE CHROMATOGRAPHY
    DAVANKOV, VA
    ROGOZHIN, SV
    SEMECHKIN, AV
    BARANOV, VA
    SANNIKOVA, GS
    JOURNAL OF CHROMATOGRAPHY, 1974, 93 (02): : 363 - 367
  • [12] Analysis of bioactive peptides by liquid chromatography high-resolution electrospray mass spectrometry
    DAgostino, PA
    Hancock, JR
    Provost, LR
    JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) : 77 - 85
  • [13] Separation and detection of phosphorylated and nonphosphorylated peptides in liquid chromatography-mass spectrometry using monolithic columns and acidic or alkaline mobile phases
    Tholey, A
    Toll, H
    Huber, CG
    ANALYTICAL CHEMISTRY, 2005, 77 (14) : 4618 - 4625
  • [14] LIGAND-EXCHANGE CHROMATOGRAPHY OF NUCLEASES
    VARLAMOV, VP
    LOPATIN, SA
    BANNIKOVA, GE
    ANDRUSHINA, IA
    ROGOZHIN, SV
    JOURNAL OF CHROMATOGRAPHY, 1986, 364 : 215 - 223
  • [15] LIGAND-EXCHANGE CHROMATOGRAPHY OF ALKALOIDS
    MURGIA, E
    WALTON, HF
    JOURNAL OF CHROMATOGRAPHY, 1975, 104 (02): : 417 - 424
  • [16] Facile detection of organometallic derivatives of peptides using electrospray mass spectrometry
    Bennett, KL
    Carver, JA
    David, DM
    KaneMaguire, LAP
    Sheil, MM
    JOURNAL OF COORDINATION CHEMISTRY, 1995, 34 (04) : 351 - 355
  • [17] Metabolism of eupatilin in rats using liquid chromatography/electrospray mass spectrometry
    Ji, HY
    Lee, HW
    Shim, HJ
    Kim, SH
    Kim, WB
    Lee, HS
    BIOMEDICAL CHROMATOGRAPHY, 2004, 18 (03) : 173 - 177
  • [18] SEPARATION AND DETECTION OF METAL-IONS USING INSITU LIGAND-EXCHANGE CHROMATOGRAPHY
    GE, HL
    WALLACE, GG
    ANALYTICAL CHEMISTRY, 1988, 60 (08) : 830 - 832
  • [19] Metal-Complex Formation in Continuous-Flow Ligand-Exchange Reactors Studied by Electrospray Mass Spectrometry
    Krabbe, J.G.
    de Boer, A.R.
    van der Zwan, G.
    Lingeman, H.
    Niessen, W.M.A.
    Irth, H.
    Journal of the American Society for Mass Spectrometry, 2007, 18 (04): : 707 - 713
  • [20] Metal-complex formation in continuous-flow ligand-exchange reactors studied by electrospray mass spectrometry
    Krabbe, J. G.
    de Boer, A. R.
    van der Zwan, G.
    Lingeman, H.
    Niessen, W. M. A.
    Irth, H.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (04) : 707 - 713