Quantitative chemical exchange saturation transfer imaging of nuclear overhauser effects in acute ischemic stroke

被引:3
|
作者
Msayib, Yunus [1 ]
Harston, George W. J. [2 ]
Ray, Kevin J. [3 ]
Larkin, James R. [4 ,5 ]
Sutherland, Brad A. [2 ,6 ]
Sheerin, Fintan [2 ]
Blockley, Nicholas P. [3 ]
Okell, Thomas W. [3 ]
Jezzard, Peter [3 ]
Baldwin, Andrew [7 ]
Sibson, Nicola R. [4 ,5 ]
Kennedy, James [2 ]
Chappell, Michael A. [3 ,8 ,9 ]
机构
[1] Univ Oxford, Inst Biomed Engn, Dept Engn Sci, Oxford, England
[2] Univ Oxford, Acute Vasc Imaging Ctr, Radcliffe Dept Med, Oxford, England
[3] Univ Oxford, Wellcome Ctr Integrat Neuroimaging, Nuffield Dept Clin Neurosci, Oxford, England
[4] Univ Oxford, Dept Oncol, CRUK, Oxford, England
[5] Univ Oxford, MRC, Oxford Inst Radiat Oncol, Oxford, England
[6] Univ Tasmania, Sch Med, Hobart, Tas, Australia
[7] Univ Oxford, Dept Chem, Oxford, England
[8] Univ Nottingham, Sir Peter Mansfield Imaging Ctr, Sch Med, Nottingham, England
[9] Univ Nottingham, Sch Med, Mental Hlth & Clin Neurosci, Nottingham, England
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
acute ischemic stroke; chemical exchange saturation transfer; nuclear Overhauser effect; AMIDE PROTON-TRANSFER; MAGNETIZATION-TRANSFER; HUMAN BRAIN; TRANSFER CEST; TRANSFER APT; IN-VIVO; MRI; STATE; PH; RELAXATION;
D O I
10.1002/mrm.29187
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose In chemical exchange saturation transfer imaging, saturation effects between -2 to -5 ppm (nuclear Overhauser effects, NOEs) have been shown to exhibit contrast in preclinical stroke models. Our previous work on NOEs in human stroke used an analysis model that combined NOEs and semisolid MT; however their combination might feasibly have reduced sensitivity to changes in NOEs. The aim of this study was to explore the information a 4-pool Bloch-McConnell model provides about the NOE contribution in ischemic stroke, contrasting that with an intentionally approximate 3-pool model. Methods MRI data from 12 patients presenting with ischemic stroke were retrospectively analyzed, as well as from six animals induced with an ischemic lesion. Two Bloch-McConnell models (4 pools, and a 3-pool approximation) were compared for their ability to distinguish pathological tissue in acute stroke. The association of NOEs with pH was also explored, using pH phantoms that mimic the intracellular environment of naive mouse brain. Results The 4-pool measure of NOEs exhibited a different association with tissue outcome compared to 3-pool approximation in the ischemic core and in tissue that underwent delayed infarction. In the ischemic core, the 4-pool measure was elevated in patient white matter (1.20 +/- 0.20) and in animals (1.27 +/- 0.20). In the naive brain pH phantoms, significant positive correlation between the NOE and pH was observed. Conclusion Associations of NOEs with tissue pathology were found using the 4-pool metric that were not observed using the 3-pool approximation. The 4-pool model more adequately captured in vivo changes in NOEs and revealed trends depending on tissue pathology in stroke.
引用
收藏
页码:341 / 356
页数:16
相关论文
共 50 条
  • [31] INTERMOLECULAR CHEMICAL EXCHANGE OF A GENERALIZED NUCLEAR OVERHAUSER EFFECT
    LAWLOR, JM
    WARREN, JP
    JOURNAL OF MAGNETIC RESONANCE, 1972, 7 (03) : 319 - &
  • [32] Uniform magnetization transfer in chemical exchange saturation transfer magnetic resonance imaging
    Lee, Jae-Seung
    Parasoglou, Prodromos
    Xia, Ding
    Jerschow, Alexej
    Regatte, Ravinder R.
    SCIENTIFIC REPORTS, 2013, 3
  • [33] Uniform magnetization transfer in chemical exchange saturation transfer magnetic resonance imaging
    Jae-Seung Lee
    Prodromos Parasoglou
    Ding Xia
    Alexej Jerschow
    Ravinder R. Regatte
    Scientific Reports, 3
  • [34] Assessment of ischemic penumbra in patients with hyperacute stroke using amide proton transfer (APT) chemical exchange saturation transfer (CEST) MRI
    Tietze, Anna
    Blicher, Jakob
    Mikkelsen, Irene Klaerke
    Ostergaard, Leif
    Strother, Megan K.
    Smith, Seth A.
    Donahue, Manus J.
    NMR IN BIOMEDICINE, 2014, 27 (02) : 163 - 174
  • [35] QUANTITATIVE-ANALYSIS OF NUCLEAR OVERHAUSER EFFECTS
    MASSEFSKI, W
    BOLTON, PH
    JOURNAL OF MAGNETIC RESONANCE, 1985, 65 (03) : 526 - 530
  • [36] Proton exchange rate of chemical exchange saturation transfer MRI constructed from direct saturation-removed omega plots to improve the assessment of patients with ischemic stroke
    Zhou, Yiran
    Wang, Zhenxiong
    Shaghaghi, Mehran
    Zhang, Guiling
    Zhu, Hongquan
    Wu, Di
    Lu, Jun
    Yan, Su
    Zhang, Shun
    Li, Li
    Li, Jia
    Cai, Kejia
    Zhu, Wenzhen
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (10) : 4865 - +
  • [37] Optimizing Pulsed-Chemical Exchange Saturation Transfer Imaging Sequences
    Zu, Zhongliang
    Li, Ke
    Janve, Vaibhav A.
    Does, Mark D.
    Gochberg, Daniel F.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (04) : 1100 - 1108
  • [38] Assessment of Carotid Artery Plaques With Chemical Exchange Saturation Transfer Imaging
    Kanematsu, Yasuhisa
    Kenji, Shimada
    Korai, Masaaki
    Izumi, Yamaguchi
    Nobuaki, Yamamoto
    Yuki, Yamamoto
    Yasushi, Takagi
    STROKE, 2024, 55
  • [39] Chemical Exchange Saturation Transfer MR Imaging Potential Clinical Applications
    Polders, Daniel Louis
    Hoogduin, Johannes Marinus
    PET CLINICS, 2013, 8 (03) : 245 - 257
  • [40] Characterization of carotid plaques using chemical exchange saturation transfer imaging
    Kanematsu, Yasuhisa
    Kanazawa, Yuki
    Shimada, Kenji
    Korai, Masaaki
    Miyamoto, Takeshi
    Sogabe, Shu
    Ishihara, Manabu
    Yamaguchi, Izumi
    Oya, Takeshi
    Yamamoto, Nobuaki
    Yamamoto, Yuki
    Miyoshi, Mitsuharu
    Harada, Masafumi
    Takagi, Yasushi
    NEURORADIOLOGY, 2024, 66 (09) : 1617 - 1624