Quantitative chemical exchange saturation transfer imaging of nuclear overhauser effects in acute ischemic stroke

被引:3
|
作者
Msayib, Yunus [1 ]
Harston, George W. J. [2 ]
Ray, Kevin J. [3 ]
Larkin, James R. [4 ,5 ]
Sutherland, Brad A. [2 ,6 ]
Sheerin, Fintan [2 ]
Blockley, Nicholas P. [3 ]
Okell, Thomas W. [3 ]
Jezzard, Peter [3 ]
Baldwin, Andrew [7 ]
Sibson, Nicola R. [4 ,5 ]
Kennedy, James [2 ]
Chappell, Michael A. [3 ,8 ,9 ]
机构
[1] Univ Oxford, Inst Biomed Engn, Dept Engn Sci, Oxford, England
[2] Univ Oxford, Acute Vasc Imaging Ctr, Radcliffe Dept Med, Oxford, England
[3] Univ Oxford, Wellcome Ctr Integrat Neuroimaging, Nuffield Dept Clin Neurosci, Oxford, England
[4] Univ Oxford, Dept Oncol, CRUK, Oxford, England
[5] Univ Oxford, MRC, Oxford Inst Radiat Oncol, Oxford, England
[6] Univ Tasmania, Sch Med, Hobart, Tas, Australia
[7] Univ Oxford, Dept Chem, Oxford, England
[8] Univ Nottingham, Sir Peter Mansfield Imaging Ctr, Sch Med, Nottingham, England
[9] Univ Nottingham, Sch Med, Mental Hlth & Clin Neurosci, Nottingham, England
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
acute ischemic stroke; chemical exchange saturation transfer; nuclear Overhauser effect; AMIDE PROTON-TRANSFER; MAGNETIZATION-TRANSFER; HUMAN BRAIN; TRANSFER CEST; TRANSFER APT; IN-VIVO; MRI; STATE; PH; RELAXATION;
D O I
10.1002/mrm.29187
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose In chemical exchange saturation transfer imaging, saturation effects between -2 to -5 ppm (nuclear Overhauser effects, NOEs) have been shown to exhibit contrast in preclinical stroke models. Our previous work on NOEs in human stroke used an analysis model that combined NOEs and semisolid MT; however their combination might feasibly have reduced sensitivity to changes in NOEs. The aim of this study was to explore the information a 4-pool Bloch-McConnell model provides about the NOE contribution in ischemic stroke, contrasting that with an intentionally approximate 3-pool model. Methods MRI data from 12 patients presenting with ischemic stroke were retrospectively analyzed, as well as from six animals induced with an ischemic lesion. Two Bloch-McConnell models (4 pools, and a 3-pool approximation) were compared for their ability to distinguish pathological tissue in acute stroke. The association of NOEs with pH was also explored, using pH phantoms that mimic the intracellular environment of naive mouse brain. Results The 4-pool measure of NOEs exhibited a different association with tissue outcome compared to 3-pool approximation in the ischemic core and in tissue that underwent delayed infarction. In the ischemic core, the 4-pool measure was elevated in patient white matter (1.20 +/- 0.20) and in animals (1.27 +/- 0.20). In the naive brain pH phantoms, significant positive correlation between the NOE and pH was observed. Conclusion Associations of NOEs with tissue pathology were found using the 4-pool metric that were not observed using the 3-pool approximation. The 4-pool model more adequately captured in vivo changes in NOEs and revealed trends depending on tissue pathology in stroke.
引用
收藏
页码:341 / 356
页数:16
相关论文
共 50 条
  • [1] Accuracy in the quantification of chemical exchange saturation transfer (CEST) and relayed nuclear Overhauser enhancement (rNOE) saturation transfer effects
    Zhang, Xiao-Yong
    Wang, Feng
    Li, Hua
    Xu, Junzhong
    Gochberg, Daniel F.
    Gore, John C.
    Zu, Zhongliang
    NMR IN BIOMEDICINE, 2017, 30 (07)
  • [2] The relayed nuclear Overhauser effect in magnetization transfer and chemical exchange saturation transfer MRI
    Zhou, Yang
    Bie, Chongxue
    van Zijl, Peter C. M.
    Yadav, Nirbhay N.
    NMR IN BIOMEDICINE, 2023, 36 (06)
  • [3] Nuclear Overhauser Enhancement Mediated Chemical Exchange Saturation Transfer Imaging at 7 Tesla in Glioblastoma Patients
    Paech, Daniel
    Zaiss, Moritz
    Meissner, Jan-Eric
    Windschuh, Johannes
    Wiestler, Benedikt
    Bachert, Peter
    Neumann, Jan Oliver
    Kickingereder, Philipp
    Schlemmer, Heinz-Peter
    Wick, Wolfgang
    Nagel, Armin Michael
    Heiland, Sabine
    Ladd, Mark Edward
    Bendszus, Martin
    Radbruch, Alexander
    PLOS ONE, 2014, 9 (08):
  • [4] Imaging of amide proton transfer and nuclear Overhauser enhancement in ischemic stroke with corrections for competing effects
    Li, Hua
    Zu, Zhongliang
    Zaiss, Moritz
    Khan, Imad S.
    Singer, Robert J.
    Gochberg, Daniel F.
    Bachert, Peter
    Gore, John C.
    Xu, Junzhong
    NMR IN BIOMEDICINE, 2015, 28 (02) : 200 - 209
  • [5] Role of chemical exchange on the relayed nuclear Overhauser enhancement signal in saturation transfer MRI
    Jin, Tao
    Kim, Seong-Gi
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (01) : 365 - 376
  • [6] Insight into the quantitative metrics of chemical exchange saturation transfer (CEST) imaging
    Heo, Hye-Young
    Lee, Dong-Hoon
    Zhang, Yi
    Zhao, Xuna
    Jiang, Shanshan
    Chen, Min
    Zhou, Jinyuan
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (05) : 1853 - 1865
  • [7] Imaging Amide Proton Transfer and Nuclear Overhauser Enhancement Using Chemical Exchange Rotation Transfer (CERT)
    Zu, Zhongliang
    Xu, Junzhong
    Li, Hua
    Chekmenev, Eduard Y.
    Quarles, C. Chad
    Does, Mark D.
    Gore, John C.
    Gochberg, Daniel F.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (02) : 471 - 476
  • [8] Magnetization Transfer Contrast-Suppressed Imaging of Amide Proton Transfer and Relayed Nuclear Overhauser Enhancement Chemical Exchange Saturation Transfer Effects in the Human Brain at 7T
    Xu, Xiang
    Yadav, Nirbhay N.
    Zeng, Haifeng
    Jones, Craig K.
    Zhou, Jinyuan
    van Zijl, Peter C. M.
    Xu, Jiadi
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (01) : 88 - 96
  • [9] Chemical exchange saturation transfer imaging and spectroscopy
    Zhou, Jinyuan
    van Zijl, Peter C. M.
    PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY, 2006, 48 (2-3) : 109 - 136
  • [10] Chemical Exchange Saturation Transfer for Epilepsy Imaging
    Brown, Joshua D.
    Kim, Hahnsung
    Sun, Philip Zhe
    Hu, Ranliang
    APPLIED RADIOLOGY, 2024, 53 (03)