The Efficiency of geothermal heat pumps with vertical ground heat exchangers: A simulation under Iraqi conditions

被引:0
|
作者
Antwan, Nazar F. [1 ]
Maree, Iyd E. [1 ]
机构
[1] Erbil Tech Coll, Refrigerat & Air Conditioning Dep, Kurdistan, Iraq
关键词
SOIL;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Geothermal heat pumps with ground source heat exchangers have been widely used for heating and cooling homes as well as for domestic water heating. A study on a small house in Erbil-Iraq was conducted to assess energy savings when using GHPs with closed loop ground source heat exchangers as compared with air-to-air heat pumps. Local climate conditions and soil properties of Erbil located in the north of Iraq were used. The simulation was performed using TRNSYS-16 software. The results of this study show that we can reduce the energy used for heating and cooling by 39% during annual when using GHP. The simulation also showed that the average COP for heating is 2.9 and for cooling is 2.6 when using air to air heat pumps and the average COP for heating is 5.6 and 3.6 for cooling when using GHP. This reduction in energy reduces the CO(2) emission as it reduces energy consumption.
引用
收藏
页码:141 / 148
页数:8
相关论文
共 50 条
  • [31] Experimental validation of a hybrid model for vertical ground heat exchangers under on-off operation conditions
    Maestre, Ismael R.
    Gonzalez Gallero, Francisco Javier
    Gomez, Pascual Alvarez
    Foncubierta Blazquez, Juan Luis
    [J]. ENERGY AND BUILDINGS, 2019, 204
  • [32] The challenge of the ground heat Exchangers: A review of heat transfer efficiency
    Wang, Xiaoyang
    Zhou, Yue
    Yao, Wanxiang
    Xia, Yueqiu
    Xu, Tongyu
    Yang, Haolin
    Xie, Huayue
    Gao, Weijun
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2024, 302
  • [33] Geothermal heat pumps
    Anon
    [J]. Energy Digest, 1990, 19 (04):
  • [34] Geothermal heat pumps
    Phetteplace, Gary
    [J]. JOURNAL OF ENERGY ENGINEERING, 2007, 133 (01) : 32 - 38
  • [35] A systemic simulation model and experiments on vertical ground heat exchangers in GCHP systems
    Cui, P
    Yang, HY
    Fang, ZH
    [J]. Tall Buildings: From Engineering to Sustainability, 2005, : 881 - 887
  • [36] The influence of heat sink temperature on the seasonal efficiency of shallow geothermal heat pumps
    Pelka, Grzegorz
    Lubon, Wojciech
    Sowizdzal, Anna
    Malik, Daniel
    [J]. INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY SYSTEMS AND ENVIRONMENTAL ENGINEERING (ASEE17), 2017, 22
  • [37] Control of Heat Transfer in a Vertical Ground Heat Exchanger for a Geothermal Heat Pump System
    Salhein, Khaled
    Kobus, C. J.
    Zohdy, Mohamed
    [J]. ENERGIES, 2022, 15 (14)
  • [38] NUMREICAL ANALYSIS OF SYSTEMS WITH VAPOUR COMPRESSOR HEAT PUMPS AND HORIZONTAL GROUND HEAT EXCHANGERS
    Hanuszkiewicz-Drapala, Malgorzata
    [J]. RYNEK ENERGII, 2010, (05): : 82 - 88
  • [39] Experimental performance of borehole heat exchangers and grouting materials for ground source heat pumps
    Desmedt, Johan
    Van Bael, Johan
    Hoes, Hans
    Robeyn, Nico
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2012, 36 (13) : 1238 - 1246
  • [40] Analysis of influence of the length of ground heat exchangers on the operation characteristics and economy of ground source heat pumps
    Zhang H.
    Han Z.
    Yang L.
    Yuan J.
    Cheng X.
    Ji M.
    Li G.
    [J]. Energy and Built Environment, 2021, 2 (02): : 127 - 136