Multianalyte Antibiotic Detection on an Electrochemical Microfluidic Platform

被引:79
|
作者
Kling, Andre [1 ,5 ]
Chatelle, Claire [2 ,3 ]
Armbrecht, Lucas [1 ,5 ]
Qelibari, Edvina [1 ]
Kieninger, Jochen [1 ]
Dincer, Can [1 ,4 ]
Weber, Wilfried [2 ,3 ]
Urban, Gerald [1 ,4 ]
机构
[1] Univ Freiburg, Dept Microsyst Engn, Georges Koehler Allee 103, DE-79110 Freiburg, Germany
[2] Univ Freiburg, Fac Biol, Schanzlestr 18, DE-79104 Freiburg, Germany
[3] Univ Freiburg, Ctr Biol Signalling Studies, Schanzlestr 18, DE-79104 Freiburg, Germany
[4] Univ Freiburg, Freiburg Mat Res Ctr, Stefan Meier Str 21, DE-79104 Freiburg, Germany
[5] Swiss Fed Inst Technol, Dept Biosyst Sci & Engn, Vladimir Prelog Weg 1-5-10, CH-8093 Zurich, Switzerland
关键词
DIAGNOSTICS; TECHNOLOGY; BIOSENSORS; IMMUNOASSAYS; RESISTANCE; SAMPLES; SYSTEM;
D O I
10.1021/acs.analchem.6b02294
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The excessive use of antibiotics in human and veterinary medicine causes the emergence of multidrug resistant bacteria. In this context, the surveillance of many different antibiotics provokes a worldwide challenge. Hence, fast and versatile multianalyte single-use biosensors are of increasing interest for many fields such as medical analysis or environmental and food control. Here we present a microfluidic platform enabling the electrochemical readout of up to eight enzyme linked assays (ELAs), simultaneously. To demonstrate the applicability of this platform for the surveillance and monitoring of antibiotics, we used highly sensitive biomolecular sensor systems for the simultaneous detection of two commonly employed antibiotic classes tetracycline and streptogramin Thus, microfluidic channel networks are designed, comprising distinct numbers of immobilization sections with a very low volume of 680 nL each. These passively metered sections can be actuated separately for an individual assay procedure. The limits of detection (LOD) are determined, with high precision, to 6.33 and 9.22 ng mL(-1) for tetracycline and pristinamycin, respectively. The employed channel material, dry film photoresist (DFR), allows an easy storage of preimmobilized assays with a shelf life of at least 3 months. Multianalyte measurements in a complex medium are demonstrated by the simultaneous detection of both antibiotics in spiked human plasma within a sample-to-result time of less than 15 min.
引用
收藏
页码:10036 / 10043
页数:8
相关论文
共 50 条
  • [31] Electrochemical detection of DNA in microfluidic systems.
    Kuhr, WG
    Brazill, SA
    Davis, CB
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 218 : U172 - U173
  • [32] Simultaneous multianalyte ELISA performed on a microarray platform
    Wiese, R
    Belosludtsev, Y
    Powdrill, T
    Thompson, P
    Hogan, M
    CLINICAL CHEMISTRY, 2001, 47 (08) : 1451 - 1457
  • [33] CAPILLARY ELECTROPHORESIS ELECTROCHEMICAL DETECTION ON A THREAD-BASED MICROFLUIDIC PLATFORM WITH PENETRATED NANOSTRUCTURED GRAPHENE OXIDE NEEDLES
    Hou, Wei-Ren
    Lin, Che-Hsin
    2024 IEEE 37TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, MEMS, 2024, : 232 - 235
  • [34] A microfluidic electrochemical sensing platform for in situ detection of trace cadmium ions (vol 14, pg 3802, 2022)
    Yuan, Yang
    Jia, Hui
    Wang, Jie
    ANALYTICAL METHODS, 2022, 14 (40) : 4030 - 4030
  • [35] A Wide Range and High Sensitivity four-channel Compact Electrochemical Biosensor for Neurotransmitter Detection on a Microfluidic Platform
    Ghodsevali, Elnaz
    Landari, Hamza
    Boukadoum, Mounir
    Gosselin, Benoit
    Miled, Amine
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 5753 - 5756
  • [36] Construction of a new versatile point-of-care testing device with electrochemical detection employing paper as a microfluidic platform
    Silva, E. T. S. G.
    Santhiago, M.
    Barragan, J. T. C.
    Kubota, L. T.
    ANALYTICAL METHODS, 2014, 6 (15) : 6133 - 6136
  • [37] A new electrochemical platform based on low cost nanomaterials for sensitive detection of the amoxicillin antibiotic in different matrices
    Wong, Ademar
    Santos, Anderson M.
    Cincotto, Fernando H.
    Moraes, Fernando C.
    Fatibello-Filho, Orlando
    Sotomayor, Maria D. P. T.
    TALANTA, 2020, 206
  • [38] A multianalyte flow electrochemical cell:: application to the simultaneous determination of carbohydrates based on bioelectrocatalytic detection
    Maestre, E
    Katakis, I
    Narváez, A
    Domínguez, E
    BIOSENSORS & BIOELECTRONICS, 2005, 21 (05): : 774 - 781
  • [39] A multianalyte electrochemical immunosensor based on patterned carbon nanotubes modified substrates for detection of pesticides
    Liu, Guozhen
    Guo, Wenqi
    Song, Dandan
    BIOSENSORS & BIOELECTRONICS, 2014, 52 : 360 - 366
  • [40] Microfluidic platform for circulating tumor cells isolation and detection
    Zhang, Jiahao
    Ren, Jie
    LI, Zirui
    Gou, Yixing
    BIOCELL, 2023, 47 (07) : 1439 - 1447