Effect of Sodium Hypochlorite Concentration on Electronic Apex Locator Reliability

被引:3
|
作者
Diemer, Franck [1 ]
Plews, Emma [1 ]
Georgelin-Gurgel, Marie [1 ]
Mishra, Lora [2 ]
Kim, Hyeon-Cheol [3 ]
机构
[1] CHU Toulouse, Clement Ader Inst, Dept Conservat Dent & Endodont, F-31400 Toulouse, France
[2] Siksha O Anusandhan, Inst Dent Sci, Dept Conservat Dent & Endodont, Bhubaneswar 751003, Odisha, India
[3] Pusan Natl Univ, Dent Res Inst, Sch Dent, Dept Conservat Dent, Yangsan 50612, South Korea
关键词
electronic apex locators; working length; concentration; sodium hypochlorite; WORKING LENGTH DETERMINATION; ROOT-ZX; VIVO EVALUATION; CANAL LENGTH; FILE SIZE; ACCURACY; IRRIGATION; IRRIGANTS; IPEX;
D O I
10.3390/ma15030863
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This ex vivo study aimed to measure the performance of an electronic apex locator (EAL) in the presence of sodium hypochlorite irrigants with different concentrations. Two EALs (Root ZX Mini and Locapex 6) were used to locate the apical foramen in 10 extracted single-rooted teeth in the presence of 0.5%, 2.5% and 5% sodium hypochlorite. Visual working lengths were also determined using #10 K-file under a microscope before the electronic measurements were made. The performance of both EALs was compared for the electronic working lengths determined under the different concentrations of sodium hypochlorite. A multiple-way ANOVA and PLSD Fisher's test with an alpha risk fixed at 5% were conducted. There were no statistical differences in the working lengths determined by both EALs between the three groups with different concentrations of sodium hypochlorite and their visual control measurements. When a +/- 0.5 mm margin was applied, the Root ZX Mini and the Locapex 6 presented 88% and 83% accuracy, respectively. Sodium hypochlorite concentration in irrigants does not affect the accuracy and reliability of either the Root ZX Mini or the Locapex 6. Electronic apex locators are reliable with any concentration of sodium hypochlorite irrigants.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Use of the electronic apex locator BINGO in the determination of the tooth length
    Moreira, EJL
    Senne, MI
    Mangeli, M
    Fidel, SR
    Fidel, RAS
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B152 - B152
  • [22] An Ex Vivo Comparison of Electronic Apex Locator Teaching Models
    Chen, Elice
    Kaing, Sivlee
    Mohan, Harry
    Ting, Shin-Yeu
    Wu, Jean
    Parashos, Peter
    JOURNAL OF ENDODONTICS, 2011, 37 (08) : 1147 - 1151
  • [23] Accuracy of an electronic apex locator in primary teeth with root resorption
    Angwaravong, O.
    Panitvisai, P.
    INTERNATIONAL ENDODONTIC JOURNAL, 2009, 42 (02) : 115 - 121
  • [24] CLINICAL-EVALUATION OF ROOT ZX ELECTRONIC APEX LOCATOR
    DUCKMANTON, P
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 758 - 758
  • [25] INFLUENCE OF THE POSITION OF THE APICAL FORAMEN ON THE ACCURACY OF ELECTRONIC APEX LOCATOR
    Siddiqui, Amna Yusuf
    Alothmani, Osama Shujaa
    ANNALS OF DENTAL SPECIALTY, 2023, 11 (03): : 5 - 8
  • [26] EVALUATION OF THE ACCURACY OF THE NEOSONO-D ELECTRONIC APEX LOCATOR
    BERMAN, LH
    FLEISCHMAN, SB
    JOURNAL OF ENDODONTICS, 1984, 10 (04) : 164 - 167
  • [27] An in vitro evaluation of the WIRELE-x electronic apex locator
    Brand, Lucas
    Dunlap, Craig A.
    Scott, Raymond
    Arias, Anna
    Peters, Ove
    AUSTRALIAN ENDODONTIC JOURNAL, 2023, 49 : 41 - 45
  • [28] An in vitro evaluation of the NO'X II electronic apex locator.
    Medioni, E
    Benarroche, O
    Bertrand, MF
    Rocca, JP
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 2843 - 2843
  • [29] The effect of sodium hypochlorite irrigant concentration on tooth surface strain
    Goldsmith, M
    Gulabivala, K
    Knowles, JC
    JOURNAL OF ENDODONTICS, 2002, 28 (08) : 575 - 579
  • [30] ACCURACY OF AN ELECTRONIC APEX LOCATOR - A CLINICAL-EVALUATION IN MAXILLARY MOLARS
    HEMBROUGH, JH
    WEINE, FS
    PISANO, JV
    ESKOZ, N
    JOURNAL OF ENDODONTICS, 1993, 19 (05) : 242 - 246