Cement mantle defects and the role of distal femoral centralising devices

被引:0
|
作者
Evans, C. R. [1 ]
Philips, S. J. [1 ]
Steele, N. A. [1 ]
Cool, W. P. [1 ]
Jones, R. Spencer [1 ]
机构
[1] Robert Jones & Agnes Hunt Orthopaed Hosp, Arthroplasty Unit, Oswestry SY10 7AG, Shrops, England
关键词
hip; cement; prosthesis;
D O I
10.1007/s00590-007-0230-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We performed an in vitro study to examine the effect of distal femoral centralising devices on the cement mantle after introduction of a tapered femoral prosthesis (Exeter no2 44 mm offset stem). This was assessed in relation to the timing of insertion (early, middle and late) and three different cement products (CMW 1, Simplex and Palamed). Forty-seven identical sawbone (R) femora model 1130 were examined after extraction of the stem. Each cement brand was divided into three groups (early, middle and late insertion times). A fourth group was added as a control, without a centraliser. Each of the femora was assessed using a 30 endoscope combined with VHS video analysis and 1 cm axial sectioning studies to examine the integrity of the cement mantle. The results were analysed statistically using the ANOVA method. These show that early insertion is important in preventing major cement mantle defects (P < 0.5). The addition of a centraliser to the stem and insertion in the late phase led to significantly greater defects in the cement mantle (P < 0.0001). This was independent of the cement type used. We conclude that there is a relationship between the late insertion of the femoral component with a distal centraliser and large cement mantle defects. We recommend insertion of the stem in the early phase of cement curing if a centraliser is used or removal of the centraliser if this stage has passed.
引用
收藏
页码:595 / 598
页数:4
相关论文
共 50 条
  • [1] Cement mantle defects and the role of distal femoral centralising devicesDéfects du manteau de ciment et rôle des centralisateurs fémoraux distaux
    C. R. Evans
    S. J. Philips
    N. A. Steele
    W. P. Cool
    R. Spencer Jones
    European Journal of Orthopaedic Surgery & Traumatology, 2007, 17 (6) : 595 - 598
  • [2] Comparison of distal and proximal centralising devices in hip arthroplasty
    Aydin, N.
    Bezer, M.
    Akgulle, A. H.
    Saygi, B.
    Kocaoglu, B.
    Guven, O.
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (04) : 945 - 948
  • [3] Comparison of distal and proximal centralising devices in hip arthroplasty
    N. Aydin
    M. Bezer
    A. H. Akgulle
    B. Saygi
    B. Kocaoğlu
    O. Guven
    International Orthopaedics, 2009, 33 : 945 - 948
  • [4] Calcium phosphate cement and locked plate augmentation of distal femoral defects: A biomechanical analysis
    DeBaun, Malcolm R.
    Williams, Joel C.
    Bennett, Chase G.
    Pridgen, Eric M.
    Tamurian, Robert M.
    Amanatullah, Derek F.
    KNEE, 2019, 26 (05): : 1020 - 1025
  • [5] Subsidence and the cement mantle in femoral impaction allografting
    Masterson, EL
    Duncan, CP
    ORTHOPEDICS, 1997, 20 (09) : 821 - 822
  • [6] DEVELOPMENTAL DEFECTS OF THE DISTAL FEMORAL METAPHYSIS
    DUNHAM, WK
    MARCUS, NW
    ENNEKING, WF
    HAUN, C
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (05): : 801 - 806
  • [7] The mechanical effect of the existing cement mantle on the in-cement femoral revision
    Keeling, Parnell
    Lennon, Alexander B.
    Kenny, Patrick J.
    O'Reilly, Peter
    Prendergast, Patrick J.
    CLINICAL BIOMECHANICS, 2012, 27 (07) : 673 - 679
  • [8] Our Management of Distal Femoral Comminuted Fractures with Femoral Defects
    Zhou, Andrew
    Jou, Eric
    Patel, Shaan
    Lu, Victor
    Zhang, James
    Krkovic, Matija
    BRITISH JOURNAL OF SURGERY, 2022, 109
  • [9] Do voids in a femoral cement mantle affect the outcome?
    Hernigou, P
    Le Mouël, S
    JOURNAL OF ARTHROPLASTY, 1999, 14 (08): : 1005 - 1010
  • [10] The femoral cement mantle in three total hip replacements
    S. J. Mellor
    L. G. Ripley
    D. M. Ricketts
    International Orthopaedics, 2004, 28 : 40 - 43