Calcium phosphate cement and locked plate augmentation of distal femoral defects: A biomechanical analysis

被引:5
|
作者
DeBaun, Malcolm R. [4 ]
Williams, Joel C. [2 ]
Bennett, Chase G. [4 ]
Pridgen, Eric M. [1 ]
Tamurian, Robert M. [3 ]
Amanatullah, Derek F. [4 ]
机构
[1] Univ Penn, Dept Orthopaed Surg, Perelman Sch Med, 3737 Market St,Suite 6121, Philadelphia, PA 19104 USA
[2] Rush Univ, Med Ctr, Dept Orthopaed Surg, 1611 W Harrison St,Suite 30,0, Chicago, IL 60612 USA
[3] Multicare Hlth Syst, Orthoped & Sports Med, 3400 South 19th St,Suite 340, Tacoma, WA 98405 USA
[4] Stanford Univ, Dept Orthoped Surg, 450 Broadway St, Redwood City, CA 94063 USA
来源
KNEE | 2019年 / 26卷 / 05期
关键词
Distal femur; Metaphyseal; Defect; Tumor; Axial; Torsion; Stiffness; GIANT-CELL TUMOR; BONE-GRAFT; STRENGTH REDUCTION; INTERNAL-FIXATION; CURETTAGE; DISEASE; FEMUR;
D O I
10.1016/j.knee.2019.07.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Bone tumors are common in the distal femur and often treated with intralesional curettage. The optimal method of stabilization of large distal femoral defects after curettage remains unclear. The goal of this study is to compare stabilization techniques for large distal femoral defects. Methods: Large defects (60 cm(3)) were milled in the distal lateral metaphysis of 45 adult composite sawbone femurs. The defect was either (1) left untreated or reconstructed with (2) locked plate fixation, (3) calcium phosphate cement packing, or (4) locked plate fixation with calcium phosphate cement packing, or (5) polymethylmethacrylate packing. Each specimen then underwent axial and torsional stiffness testing followed by torsional loading to failure. The data were analyzed using ANOVA with Tukey-Kramer post-hoc analysis. Results: The calcium phosphate cement filled defect with a locked plate was the stiffest construct in axial and torsional loading as well as the strongest in torque to failure. However, this difference only reached significance with respect to all other groups in torque to failure testing. The calcium phosphate cement filled defect with a locked plate was significantly stiffer than three of the four other groups in both axial and torsional stiffness testing. Conclusions: These results indicate that calcium phosphate cement, with or without the addition of locked plate fixation, may provide improved construct stability under time zero testing conditions. This result warrants further testing under cyclic loading condition and consideration for fixation of large femoral metaphyseal defects in future clincal trails. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:1020 / 1025
页数:6
相关论文
共 50 条
  • [1] Contained femoral defects - Biomechanical analysis of pin augmentation in cement
    Murray, PJ
    Damron, TA
    Green, JK
    Morgan, HD
    Werner, FW
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (420) : 251 - 256
  • [2] Locking plate augmentation of polymethylmethacrylate-filled distal femoral defects: A biomechanical study
    Ferlauto, Harrison R.
    Belanger, Bruno
    Lazarides, Alexander L.
    Visgauss, Julia D.
    Brigman, Brian E.
    Eward, William C.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2025, 43 (01) : 210 - 216
  • [3] Hip screw augmentation with an in situ setting calcium phosphate cement: An in vitro biomechanical analysis
    Moore, DC
    Frankenburg, EP
    Goulet, JA
    Goldstein, SA
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (08) : 577 - 583
  • [4] Opening wedge distal femoral varus osteotomy using the Puddu plate and calcium phosphate bone cement
    Dewilde, T. R.
    Dauw, J.
    Vandenneucker, H.
    Bellemans, J.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (01) : 249 - 254
  • [5] Biomechanical analysis of distal femoral fracture fixation: dynamic condylar screw versus locked compression plate
    Narsaria, Nidhi
    Singh, Ashutosh K.
    Rastogi, Amit
    Singh, Vakil
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2014, 19 (05) : 770 - 775
  • [6] Opening wedge distal femoral varus osteotomy using the Puddu plate and calcium phosphate bone cement
    T. R. Dewilde
    J. Dauw
    H. Vandenneucker
    J. Bellemans
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 249 - 254
  • [7] Effect of Calcium Phosphate Bone Cement Augmentation on Volar Plate Fixation of Unstable Distal Radial Fractures in the Elderly
    Kim, Jae Kwang
    Do Koh, Young
    Kook, Seung Hwan
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (07): : 609 - 614
  • [8] Augmentation of posterior wall acetabular fracture fixation using calcium-phosphate cement: A biomechanical analysis
    Olson, Steven A.
    Kadrmas, Michael W.
    Hernandez, Jon D.
    Glisson, Richard R.
    West, Jesse L.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (09) : 608 - 616
  • [9] Impact of cement-augmented condylar screws in locking plate osteosynthesis for distal femoral fractures - A biomechanical analysis
    Bliemel, Christopher
    Oberkircher, Ludwig
    Bockmann, Benjamin
    Petzold, Eric
    Aigner, Rene
    Heyse, Thomas Jan
    Ruchholtz, Steffen
    Buecking, Benjamin
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (12): : 2688 - 2693
  • [10] Reconstruction of noncontained distal femoral defects with polymethylmethacrylate and crossed-screw augmentation: A biomechanical study
    Toy, PC
    France, J
    Randall, RL
    Neel, MD
    Shorr, RI
    Heck, RK