Percutaneous closure of giant ascending aortic pseudoaneurysm: 22 years after modified BlalockTaussig shunt with a septal occluder device

被引:0
|
作者
Massoud, Ikram [1 ]
Yehia, Atef [1 ]
机构
[1] Natl Heart Inst, Dept Pediat Cardiol, Giza, Egypt
关键词
Pseudoaneurysm; ascending aorta; device closure; FALSE ANEURYSMS; REPAIR; SURGERY;
D O I
10.1017/S1047951121003358
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pseudoaneurysm of the ascending aorta is rare (1-2%) and a potentially fatal complication following cardiac surgeries. Surgical repair is still the gold standard treatment of ascending aortic pseudoaneurysm. However, endovascular repair methods including stent grafts and Septal Occluder devices have been reported. We report a case of 38-year-old female patient who presented with giant ascending aortic pseudoaneurysm, and aortopulmonary fistula 22 years after modified BlalockTaussig shunt was managed by the transcatheter method. Septal Occluder device 20 mm diameter was delivered to seal the ostium.
引用
收藏
页码:652 / 655
页数:4
相关论文
共 38 条
  • [31] Complete atrioventricular block after percutaneous closure of perimembranous ventricular septal defect with modified double-disk occluder
    Bai, Y.
    Qin, Y. W.
    Zhao, X. X.
    Zheng, X.
    Wu, H.
    Chen, S. P.
    Hu, J. Q.
    Huang, X. M.
    You, X. H.
    Li, W. P.
    EUROPEAN HEART JOURNAL, 2011, 32 : 668 - 668
  • [32] Late device dislodgement after percutaneous closure of mitral prosthesis paravalvular leak with amplatzer muscular ventricular septal defect occluder
    Ussia, Gian Paolo
    Scandura, Salvatore
    Calafiore, Antonio M.
    Mangiafico, Sara
    Meduri, Rocco
    Galassi, Alfredo R.
    Tamburino, Corrado
    CIRCULATION, 2007, 115 (08) : E208 - E210
  • [33] Perforation of the left atrium and aortic bulb two years after percutaneous closure of atrial septal defect
    Stankiewicz, Adrian
    Matlak, Krzysztof
    Juszczyk, Grzegorz
    Sewastianowicz, Adam
    Dobrzycki, Slawomir
    Poniatowski, Boguslaw
    Hirnle, Tomasz
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2011, 7 (04): : 320 - 322
  • [34] Device closure of iatrogenic membranous ventricular septal defects after prosthetic aortic valve replacement using the amplatzer membranous ventricular septal defect occluder
    Holzer, R
    Latson, L
    Hijazi, ZM
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 62 (02) : 276 - 280
  • [35] Abdominal Aortic Embolization of a Figulla Atrial Septum Occluder Device, at the Level of the Celiac Axis, after an Atrial Septal Defect Closure: Hybrid Attempt
    Jahrome, A. Kh.
    Stella, Peter R.
    Leijdekkers, Vanessa J.
    Guyomi, Siyrous Hoseyni
    Moll, Frans L.
    VASCULAR, 2010, 18 (01) : 59 - 61
  • [36] Percutaneous closure of the left atrial appendage after failed surgical closure using a septal occluder device guided by real-time 4-dimensional intracardiac echocardiography
    Carneiro, Herman A.
    Cook, Arianna
    Belani, Kiran
    Benzuly, Keith
    Knight, Bradley
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (08) : 1959 - 1962
  • [37] Aortic root rupture with giant thoracic haematoma: transient improvement after percutaneous closure with ASD-amplatzer device
    Ferrarello, Santo
    Moccetti, Tiziano
    Van den Berg, Jos C.
    Pedrazzini, Giovanni B.
    EUROPEAN HEART JOURNAL, 2013, 34 (48) : 3706 - 3706
  • [38] Percutaneous closure of multiple ventricular septal defects: simultaneous use of muscular ventricular septal defect device and Multi-Fenestrated Septal Occluder - "Cribriform" to close residual ventricular septal defects after complex cardiac surgery in a child
    Maiya, Shreesha S.
    Patel, Smruti V.
    Reddy, Chinnaswamy
    Pujar, Suresh V.