Amperometric H2O2 biosensor based on poly-thionine nanowire/HRP/nano-Au-modified glassy carbon electrode

被引:68
|
作者
Shi, Ai Wu [1 ]
Qu, Feng Li [1 ]
Yang, Ming Hui [1 ]
Shen, Guo Li [1 ]
Yu, Ru Qin [1 ]
机构
[1] Hunan Univ, Chem & Chem Engn Coll, State Key Lab Chemo Biosensing & Chemomet, Changsha 410082, Peoples R China
基金
中国国家自然科学基金;
关键词
alumina template membrane; thionine; electrodeposition; horseradish peroxidase; nano-Au; nanowires;
D O I
10.1016/j.snb.2007.09.062
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Poly-thionine nanowire/HRP/nano-Au composite nanomaterial was developed to fabricate the H2O2 biosensor. Poly-thionine nanowires (PTHNWs) have been synthesized by electrodeposition in porous anodic aluminum oxide (AAO) template. The morphological characterization of PTHNWs was examined by scanning electron microscopy (SEM) and transmission electron microscope (TEM). The nanowires prepared by this method can be used to encapsulate horseradish peroxidase (HRP) and nano-Au by in situ electrochemical copolymerization. The resulting PTHNWs-HRP-nano-Au material facilitates electron-transfer process in electrochemical sensor design. The PTHNWs-HRP-nano-Au film-modified electrode showed to be excellent amperometric sensors for H2O2. In pH 6.98 phosphate buffer, almost interference-free determination of H2O2 is realized at -0.1 V versus SCE with a linear range of 5 x 10(-7) to 1.3 x 10(-2) M, a correlation coefficient of 0.998 and response time <5 s. The sensitivity of the H2O2 biosensor is up to 168 mu A mM(-1) cm(-2) and the detection limit is 0.3 mu M. Furthermore, the biosensor exhibited long-term stability, and good reproducibility. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:779 / 783
页数:5
相关论文
共 50 条
  • [41] Modified Glassy Carbon Rotating Disk Electrode for Determination of Heterogeneous Reaction Rate Constant of H2O2 Decomposition
    Amirfakhri, Seyed Javad
    Meunier, Jean-Luc
    Berk, Dimitrios
    ELECTROANALYSIS, 2015, 27 (07) : 1750 - 1757
  • [42] A glassy carbon electrode modified with a film composed of cobalt oxide nanoparticles and graphene for electrochemical sensing of H2O2
    Li, Su-Juan
    Du, Ji-Min
    Zhang, Jia-Ping
    Zhang, Meng-Jie
    Chen, Jing
    MICROCHIMICA ACTA, 2014, 181 (5-6) : 631 - 638
  • [43] A glassy carbon electrode modified with a film composed of cobalt oxide nanoparticles and graphene for electrochemical sensing of H2O2
    Su-Juan Li
    Ji-Min Du
    Jia-Ping Zhang
    Meng-Jie Zhang
    Jing Chen
    Microchimica Acta, 2014, 181 : 631 - 638
  • [44] A sensitive amperometric immunosensor for alpha-fetoprotein based on carbon nanotube/DNA/Thi/nano-Au modified glassy carbon electrode
    Ran, Xiao-Qi
    Yuan, Ruo
    Chai, Ya-Qin
    Hong, Cheng-Lin
    Qian, Xiao-Qing
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2010, 79 (02) : 421 - 426
  • [45] Electrochemical Fabrication of Nano Manganese Oxide Modified Electrode for the Detection of H2O2
    Thiagarajan, Soundappan
    Tsai, Tsung Hsuan
    Chen, Shen-Ming
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (06): : 2235 - 2245
  • [46] An amperometric hydrogen peroxide biosensor based on Co3O4 nanoparticles and multiwalled carbon nanotube modified glassy carbon electrode
    Kacar, Ceren
    Dalkiran, Berna
    Erden, Pinar Esra
    Kilic, Esma
    APPLIED SURFACE SCIENCE, 2014, 311 : 139 - 146
  • [47] Amperometric bienzyme glucose biosensor based on carbon nanotube modified electrode with electropolymerized poly(toluidine blue O) film
    Wang, Wenju
    Wang, Fang
    Yao, Yanli
    Hu, Shengshui
    Shiu, Kwok-Keung
    ELECTROCHIMICA ACTA, 2010, 55 (23) : 7055 - 7060
  • [48] Flow Injection Amperometric Analysis of H2O2 at Platinum Nanoparticles Modified Pencil Graphite Electrode
    Karakaya, Serkan
    Dilgin, Yusuf
    ELECTROANALYSIS, 2017, 29 (06) : 1626 - 1634
  • [49] H2O2 biosensor based on horseradish peroxidase immobilized onto the zinc sulphide-graphene-chitosan modified carbon paper electrode
    Suganthi, G.
    Ramanathan, Giriprasath
    Arockiadoss, T.
    Sivagnanam, Uma Tiruchirapalli
    BULLETIN OF MATERIALS SCIENCE, 2021, 44 (01)
  • [50] INFLUENCE OF GRAPHITE POWDER, ADDITIVES AND ENZYME IMMOBILIZATION PROCEDURES ON A MEDIATORLESS HRP-MODIFIED CARBON-PASTE ELECTRODE FOR AMPEROMETRIC FLOW-INJECTION DETECTION OF H2O2
    POPESCU, IC
    ZETTERBERG, G
    GORTON, L
    BIOSENSORS & BIOELECTRONICS, 1995, 10 (05): : 443 - 461