Intra- and inter-fraction relative range verification in heavy-ion therapy using filtered interaction vertex imaging

被引:4
|
作者
Hymers, Devin [1 ]
Kasanda, Eva [1 ]
Bildstein, Vinzenz [1 ]
Easter, Joelle [1 ]
Richard, Andrea [2 ,3 ]
Spyrou, Artemis [2 ]
Hohr, Cornelia [4 ]
Mucher, Dennis [1 ,4 ]
机构
[1] Univ Guelph, Dept Phys, Guelph, ON, Canada
[2] Michigan State Univ, Natl Superconducting Cyclotron Lab, E Lansing, MI 48824 USA
[3] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[4] TRIUMF, Vancouver, BC, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 24期
基金
美国国家科学基金会; 加拿大自然科学与工程研究理事会;
关键词
interaction vertex imaging; heavy-ion therapy; silicon detectors; range monitoring; RADIOTHERAPY; BEAMS; MODEL; IMPLEMENTATION; PROSTATE;
D O I
10.1088/1361-6560/ac3b33
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Heavy-ion therapy, particularly using scanned (active) beam delivery, provides a precise and highly conformal dose distribution, with maximum dose deposition for each pencil beam at its endpoint (Bragg peak), and low entrance and exit dose. To take full advantage of this precision, robust range verification methods are required; these methods ensure that the Bragg peak is positioned correctly in the patient and the dose is delivered as prescribed. Relative range verification allows intra-fraction monitoring of Bragg peak spacing to ensure full coverage with each fraction, as well as inter-fraction monitoring to ensure all fractions are delivered consistently. To validate the proposed filtered interaction vertex imaging (IVI) method for relative range verification, a O-16 beam was used to deliver 12 Bragg peak positions in a 40 mm poly-(methyl methacrylate) phantom. Secondary particles produced in the phantom were monitored using position-sensitive silicon detectors. Events recorded on these detectors, along with a measurement of the treatment beam axis, were used to reconstruct the sites of origin of these secondary particles in the phantom. The distal edge of the depth distribution of these reconstructed points was determined with logistic fits, and the translation in depth required to minimize the chi (2) statistic between these fits was used to compute the range shift between any two Bragg peak positions. In all cases, the range shift was determined with sub-millimeter precision, to a standard deviation of the mean of 220(10) mu m. This result validates filtered IVI as a reliable relative range verification method, which should be capable of monitoring each energy step in each fraction of a scanned heavy-ion treatment plan.
引用
收藏
页数:20
相关论文
共 16 条
  • [1] Sub-Millimeter Range Monitoring in Heavy-Ion Therapy with Filtered Interaction Vertex Imaging (IVI)
    Hymers, D.
    Kasanda, E.
    Bildstein, V.
    Easter, J.
    Spyrou, A.
    Hoehr, C.
    Muecher, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E476 - E476
  • [2] Evaluation of intra- and inter-fraction motion in breast radiotherapy using electronic portal cine imaging
    Kron, T
    Lee, C
    Perera, F
    Yu, E
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2004, 3 (05) : 443 - 449
  • [3] Evaluation of intra- and inter-fraction movement of the cervix during intensity modulated radiation therapy
    Haripotepornkul, Nora H.
    Nath, Sameer K.
    Scanderbeg, Daniel
    Saenz, Cheryl
    Yashar, Catheryn M.
    RADIOTHERAPY AND ONCOLOGY, 2011, 98 (03) : 347 - 351
  • [4] Range verification in heavy-ion therapy using a hadron tumour marker
    Kasanda, E.
    Bildstein, V
    Hymers, D.
    Easter, J.
    Richard, A. L.
    Baumann, T.
    Spyrou, A.
    Hoehr, C.
    Muecher, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (19):
  • [5] Dosimetric Impact of intra- and inter-fraction motion in liver pencil beam scanning proton therapy
    Nankali, Saber
    Worm, Esben Schjodt
    Thomsen, Jakob Borup
    Stick, Line Bjerregaard
    Hoyer, Morten
    Weber, Britta
    Mortensen, Hanna Rahbek
    Poulsen, Per Rugaard
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4193 - S4196
  • [6] Electronic portal cine imaging reveals only minimal intra- and inter-fraction motion intangential breast irradiation
    Reist, M
    Vetterli, D
    Greiner, RH
    Gruber, G
    STRAHLENTHERAPIE UND ONKOLOGIE, 2005, 181 : 139 - 139
  • [7] Range Verification in Heavy-Ion Therapy with a Hadron Tumour Marker (HTM)
    Kasanda, E.
    Easter, J.
    Hymers, D.
    Burbadge, C.
    Bildstein, V.
    Spyrou, A.
    Hoehr, C.
    Muecher, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E840 - E841
  • [8] Monte Carlo investigation of sub-millimeter range verification in carbon ion radiation therapy using interaction vertex imaging
    Hymers, Devin
    Mucher, Dennis
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (04):
  • [9] Digital imaging of inter-fraction and intra-fraction deviations in mono-isocentric breast and nodal radiation therapy (RT)
    Patenaude, VV
    Truong, PT
    Bishop, J
    Sandwith, W
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S391 - S391
  • [10] Range verification system using positron emitting beams for heavy-ion radiotherapy
    Iseki, Y
    Kanai, T
    Kanazawa, M
    Kitagawa, A
    Mizuno, H
    Tomitani, T
    Suda, M
    Urakabe, E
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (14): : 3179 - 3195