Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla

被引:3
|
作者
Shen, Yihan [1 ]
Dai, Qinggang [1 ]
Tao, Baoxin [1 ]
Huang, Wei [2 ]
Wang, Feng [2 ]
Lan, Kengliang [1 ]
Sun, Yuanyuan [1 ]
Ling, Xiaowan [1 ]
Yan, Lijun [1 ]
Wang, Yueping [1 ]
Wu, Yiqun [1 ]
机构
[1] Shanghai Jiao Tong Univ, Dent Ctr 2, Shanghai Peoples Hosp 9,Shanghai Key Lab Stomatol, Sch Med,Coll Stomatol,Natl Ctr Stomatol,Natl Clin, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Dept Dent Implantol, Shanghai Peoples Hosp 9,Shanghai Key Lab Stomatol, Sch Med,Coll Stomatol,Natl Ctr Stomatol,Natl Clin, Shanghai, Peoples R China
来源
基金
上海市自然科学基金;
关键词
STEREOLITHOGRAPHIC SURGICAL GUIDES; ACCURACY; REHABILITATION; CLASSIFICATION; SURGERY;
D O I
10.3791/62489
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Zygomatic implants (ZIs) are an ideal way to address cases of a severely atrophic edentulous maxilla and maxilla defects because they replace extensive bone augmentation and shorten the treatment cycle. However, there are risks associated with the placement of ZIs, such as penetration of the orbital cavity or infra-temporal fossa. Furthermore, the placement of multiple ZIs makes this surgery risky and more difficult to perform. Potential intraoperative complications are extremely dangerous and may cause irreparable losses. Here, we describe a practical, feasible, and reproducible protocol for a real-time surgical navigation system for precisely placing quad-zygomatic implants in the severely atrophic maxilla of patients with residual bone that does not meet the requirements of conventional implants. Hundreds of patients have received ZIs at our department based on this protocol. The clinical outcomes have been satisfactory, the intraoperative and postoperative complications have been low, and the accuracy indicated by infusion of the designed image and postoperative three-dimensional image has been high. This method should be utilized during the entire surgical procedure to ensure ZI placement safety.
引用
收藏
页数:15
相关论文
共 34 条
  • [31] An investigation of the dynamic characteristics of super high-rise buildings using real-time kinematic-global navigation satellite system technology
    Xiong, Chun-Bao
    Niu, Yan-Bo
    Li, Zhi
    ADVANCES IN STRUCTURAL ENGINEERING, 2018, 21 (05) : 783 - 792
  • [32] Dynamic Displacement Estimation for Long-Span Bridges Using Acceleration and Heuristically Enhanced Displacement Measurements of Real-Time Kinematic Global Navigation System
    Kim, Kiyoung
    Sohn, Hoon
    SENSORS, 2020, 20 (18) : 1 - 18
  • [33] A novel dynamic robotic moving phantom system for patient-specific quality assurance in real-time tumor-tracking radiotherapy
    Shiinoki, Takehiro
    Fujii, Fumitake
    Fujimoto, Koya
    Yuasa, Yuki
    Sera, Tatsuhiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (07): : 16 - 28
  • [34] S8 Navigation system combined with an ultrasonic osteotome for three-dimensional real-time dynamic visualization decompression to reduce postoperative neurological deterioration in thoracic ossification of the ligamentum flavum
    Li, Shuai
    Du, Jinpeng
    Wang, Xiaohui
    Huang, Yunfei
    Huang, Yansheng
    Chang, Zhen
    Yan, Liang
    Zhang, Xuefang
    Shi, Zhengwei
    Zhao, Zhigang
    Gao, Lin
    Zhao, Songchuan
    He, Baorong
    EUROPEAN SPINE JOURNAL, 2025, 34 (03) : 1004 - 1017