The CDF SVX II upgrade silicon detector: silicon sensors performances

被引:0
|
作者
Bolla, G [1 ]
机构
[1] Purdue Univ, Dept Phys, W Lafayette, IN 47907 USA
关键词
D O I
10.1016/S0168-9002(97)91248-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A microstrip silicon detector SVX II (The CDF II Technical Design Report, CDF Collaboration, FERMILAB-Pub-96/360-E [1]) has been proposed for the upgrade of CDF to be installed in 1999 for Run II of the Tevatron. Three barrels of live layers of double-sided silicon microstrip detectors will cover the interaction region. Beginning with a description of the project the attention will be focused on the silicon sensors performances. The prototypes studies (D. Bortoletto, Nucl, Inst. and Meth, A 386 (1997) 87 [2]) led to the final choice that is investigated here. Full characterization of the production Hamamatsu sensors is presented including probe station measurements and test beam results before and after irradiation. Analysis of data taken during the CDF beam test at the FNAL Meson Beamline and related S/N, resolution and charge collection measurements are reported. (C) 1998 Elsevier Science B,V. All rights reserved.
引用
收藏
页码:112 / 116
页数:5
相关论文
共 50 条
  • [21] Selected mechanical engineering topics of the SVX II detector at CDF
    Ratzmann, P
    Flaugher, B
    Howell, J
    Hrycyk, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3): : 216 - 217
  • [22] The CDF Run IIa silicon detector and its upgrade run IIb
    Issever, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 549 (1-3): : 7 - 10
  • [23] Sensors for the CDF Run2b silicon detector
    Hara, K
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 903 - 907
  • [24] The CDF Run II silicon detector: Aging studies
    Garcia, Jose E.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 92 - 95
  • [25] Sensors for the CDF Run2b silicon detector
    Akimoto, T
    Aoki, M
    Azzi, P
    Bacchetta, N
    Behari, S
    Benjamin, D
    Bisello, D
    Bolla, G
    Booth, P
    Bortoletto, D
    Burghard, A
    Busetto, G
    Cabrera, S
    Canepa, A
    Cardoso, G
    Chertok, M
    Ciobanu, CI
    Cooke, P
    Derylo, G
    Fang, I
    Feng, EJ
    Fernandez, JP
    Flaugher, B
    Freeman, J
    Galtieri, L
    Galyardt, J
    Garcia-Sciveres, M
    Giurgiu, G
    Gorelov, I
    Haber, C
    Hale, D
    Hara, K
    Harr, R
    Hill, C
    Hoeferkamp, M
    Hoff, J
    Holbrook, B
    Hong, SC
    Hrycyk, M
    Hsiung, TH
    Incandela, J
    Jeon, EJ
    Joo, KK
    Junk, T
    Kahkola, H
    Karjalainen, S
    Kim, S
    Kobayashi, K
    Kong, DJ
    Krieger, B
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (04) : 1546 - 1554
  • [26] Status and performance of the CDF Run II silicon detector
    Maki, Tuula
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (02): : 723 - 725
  • [27] Radiation Life of the CDF Run II Silicon Detector
    Redondo, Ignacio
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 503 - 506
  • [28] The CDF RUN II Silicon Detector: Aging Studies
    Redondo Fernandez, Ignacio
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 451 - 455
  • [29] Status and performance of the CDF Run II silicon detector
    Wallny, RS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 546 (1-2): : 56 - 59
  • [30] Operational experience with the CDF RUN II silicon detector
    Stanitzki, Marcel
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1101 - 1105