The Correlation Analysis of PM Inter-turn Fault based on Stator Current and Vibration Signal

被引:0
|
作者
Li, Yongcan [1 ]
Liang, Yongchun [1 ]
机构
[1] Hebei Univ Sci & Technol, Dept Elect Engn, Shijiazhuang, Peoples R China
关键词
Inter-turn fault; Stator current; Vibration; The correlation Analysis; PMSM;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Inter-turn fault is the most probably fault in permanent motor. It is important to find an useful method to diagnose the inter-turn fault before the permanent motor is broken. Stator windings current is always used to evaluate the inter-turn fault. But it is difficult to find small inter-turn fault using only stator current. The vibration signal and stator current are all detected and analyzed in this paper. LabVIEW is used to control the data acquisition system and receive the vibration and stator current signal. The vibration spectrum and stator current spectrum are obtained by FFT. These two spectrum is fused with the correlation analysis method. The correlation analysis method gives out more obvious feather of the inter-turn short circuit fault. Test shows that the permanent experimental system and the correlation analysis method can fully meet the requirements of permanent magnet synchronous motor fault test and research.
引用
收藏
页码:1733 / 1737
页数:5
相关论文
共 50 条
  • [1] Fault Detection of Stator Inter-Turn Short-Circuit in PMSM on Stator Current and Vibration Signal
    Liang, Hong
    Chen, Yong
    Liang, Siyuan
    Wang, Chengdong
    [J]. APPLIED SCIENCES-BASEL, 2018, 8 (09):
  • [2] Vibration Analysis of DFIG Stator Winding Inter-turn Short Circuit Fault
    Qin, Peng
    Zhang, Zhiyan
    Sun, Yusheng
    Liu, Hua
    Ren, Haizhou
    [J]. PROCEEDINGS OF 2018 INTERNATIONAL CONFERENCE ON INFORMATION SYSTEMS AND COMPUTER AIDED EDUCATION (ICISCAE 2018), 2018, : 436 - 442
  • [3] Analysis of PM Inter-turn fault Based on LabVIEW and FFT
    Liang, Yongchun
    [J]. MEASUREMENT TECHNOLOGY AND ENGINEERING RESEARCHES IN INDUSTRY, PTS 1-3, 2013, 333-335 : 1597 - 1600
  • [4] Stator Inter-turn Fault Modelling and Analysis on Induction Motor based on MCCM
    Babu, Akash C.
    Seshadrinath, Jeevanand
    [J]. 2021 INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND FUTURE ELECTRIC TRANSPORTATION (SEFET), 2021,
  • [5] Diagnosis of Inter-Turn Short-Circuit Stator Winding Fault in PMSM Based on Stator Current and Noise
    Liang, Yongchun
    [J]. 2014 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2014, : 138 - 142
  • [6] Stator Inter-turn Fault Detection of Synchronous Machines Using Field Current Signature Analysis
    Neti, Prabhakar
    Nandi, Subhasis
    [J]. CONFERENCE RECORD OF THE 2006 IEEE INDUSTRY APPLICATIONS CONFERENCE, FORTY-FIRST IAS ANNUAL MEETING, VOL 1-5, 2006, : 2360 - 2367
  • [7] FEM Simulation and Analysis on Stator Winding Inter-turn Fault in DFIG
    Chen, Yu
    Wang, Lulu
    Wang, Zihao
    Rehman, Attiq Ur
    Cheng, Yonghong
    Zhao, Yong
    Tanaka, Toshikatsu
    [J]. 2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 244 - 247
  • [8] Model development and small-signal stability analysis of DFIG with stator winding inter-turn fault
    Sun, Liling
    Xu, Boqiang
    Du, Wenjuan
    Wang, Haifeng
    [J]. IET RENEWABLE POWER GENERATION, 2017, 11 (03) : 338 - 346
  • [9] Fault diagnosis of inter-turn short circuit in turbogenerator rotor windings based on vibration-current signal fusion
    Fang, Ruiming
    Liu, Zilin
    Peng, Changqing
    Yang, Yulei
    Zhang, Shuming
    [J]. ENERGY REPORTS, 2023, 9 : 316 - 323
  • [10] Development of a cross correlation based induction motor stator winding inter-turn fault severity indicator
    Mishra, Partha
    Das, Santanu
    [J]. FOUNDATIONS AND FRONTIERS IN COMPUTER, COMMUNICATION AND ELECTRICAL ENGINEERING, 2016, : 149 - 155