Fuzzy logic and Selectivity controllers for the paralleling of four-leg shunt active power filters based on Three Dimensional Space Vector Modulation

被引:0
|
作者
Chebabhi, Ali [1 ]
Fellah, Mohammed K. [1 ]
Kessal, Abdelhalim [2 ]
Benkhoris, Mohamed F. [3 ]
机构
[1] Univ Djillali Liabes Sidi Bel Abbes, Dept Elect Engn, ICEPS Lab, Sidi Bel Abbes, Algeria
[2] Univ Bordj Bou, Fac Sci & Technol, Arreridj, Algeria
[3] Univ Nantes, IREENA Lab, St Nazaire, France
关键词
Paralleling of four-leg shunt active power filters; Selectivity of control; (FLC); 3D-SVM; pq0; theory; Zero-sequence current; Harmonic; Reactive power compensation; switching losses;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A new structure of paralleling four leg shunt active power filters is presented in order to compensate the four-wire electrical network supplying the high power of non-linear single-phase loads. An effective selectivity of control with fuzzy logic and Three Dimensional Space Vector Modulation (3D-SVM) introduced in this configuration of SAPFs to maintain the same amplitude and frequency of output current of each inverter, this is necessary to determine the numbers of inverters in service and their frequency of commutation according to the power of non-linear single-phase loads, to make operating or stopping the inverters without disturbing the performance of paralleling SAPFs. The fuzzy logic controller (FLC) and Three Dimensional Space Vector Modulation (3D-SVM) is necessary to robustness, minimizing the harmonics of source currents, reducing the magnitude of neutral current, eliminating the zero-sequence current, compensating reactive power in the four-wire distribution network, stabilizing the DC bus voltage, switching losses, and to fixe switching frequency in inverters. Also, a instantaneous real, imaginary and zero-sequence powers pq0 theory in the alpha beta omicron-axes is presented to generate the reference currents which should be injected by the paralleled four leg SAPFs.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Fuzzy logic controllers for three levels shunt active power filter compensated by three-levels stabilizing Space Vector Modulation to Fixed Switching Frequency and switching lasses reducing under unbalanced load
    ICEPS Laboratory, Djillali Liabes University of Sidi Bel-Abbes, Algeria
    不详
    不详
    [J]. Mediterr. J. Meas. Control, 1 (357-366):
  • [42] Single phase application of Space Vector Pulse Width Modulation for shunt active power filters
    Koochaki, A.
    Fatbi, S. H.
    Divandari, M.
    [J]. 2007 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, PROCEEDINGS, VOLS 1-8, 2007, : 611 - +
  • [43] Power Quality Improvement using a Three Dimensional Space Vector Modulation with SRF theory for Three Level Neutral Point Clamped Four Leg Shunt Active Power Filter Controlling in dq0 axes
    Chebabhi, Ali
    Fellah, Mohammed Karim
    Kessal, Abdelhalim
    Benkhoris, Mohamed F.
    [J]. 2015 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2015, : 290 - +
  • [44] Average Modeling and Carrier-Based Control Strategies Applied to a Three-Phase Four-Leg Shunt Active Power Filter
    Kanaan, H. Y.
    Mougharbel, I.
    Al-Haddad, K.
    [J]. INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2008, 3 (05): : 844 - 857
  • [45] A Simplified Space Vector Pulse Width Modulation Method Based on ghγ Coordinates System for the Three-Level Four-Leg Inverter
    Zhang Z.
    Chen H.
    Chen S.
    Zhang Z.
    Li Y.
    [J]. Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2023, 38 (16): : 4324 - 4338
  • [46] A Boost Converter Control Based Three-phase Four-leg Active Power Filter
    Yang, Liu
    Hu, Dakai
    Liu, Fei
    Sun, Jianjun
    Zha, Xiaoming
    [J]. 2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [47] Using SHM-PWAM Modulation Technique for Three-Phase Four-Leg Active Power Filter
    Zabihian, Ameneh
    Varjani, Ali Yazdian
    Ghoreishy, Hoda
    [J]. 2014 22ND IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2014, : 648 - 653
  • [48] On the space vector modulation and limiting algorithms for three-phase four-leg voltage source inverter in abc coordinates
    Botterón, F
    de Camargo, RF
    Gründling, HPHA
    Pinheiro, JR
    Hey, HL
    [J]. IECON-2002: PROCEEDINGS OF THE 2002 28TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-4, 2002, : 12 - 17
  • [49] Study on simply space-vector and one-cycle control strategy for three-phase four-leg active power filter
    Wang Yong
    Lv Hongli
    [J]. SENSORS, AUTOMATIC MEASUREMENT, CONTROL, AND COMPUTER SIMULATION, PTS 1 AND 2, 2006, 6358
  • [50] Fuzzy logic controller for three-phase four-leg five-level shunt active power filter under unbalanced non-linear load and distorted voltage conditions
    Benaissa A.
    Rabhi B.
    Moussi A.
    Benkhoris M.F.
    [J]. International Journal of System Assurance Engineering and Management, 2014, 5 (03) : 361 - 370